Fluid & Gas Flow Equipment

Portable Holiday Detectors have ergonomic design.

Portable Holiday Detectors have ergonomic design.

Self-contained SPYÂ-® Models 780 and 790, equipped with topside handle and ergonomic pistol grip, have built-in jeep meter that lets users inspect coatings on 2-60 in. pipe diameters. To test integrity of thin film coatings, Model 780 has 1,000-5,000 V range, while Model 790, with 5,000-35,000 V range, inspects extra thick and somastic coatings. Both feature infinite voltage settings, audible...

Read More »
High-Pressure Pump is designed for bolting applications.

High-Pressure Pump is designed for bolting applications.

Suited for use as power sources for hydraulic torque wrenches, ZU4T-Series incorporates LCD readout and 1.25 kW universal electric motor. Brush design features auto-stop shunt, while auto cycle feature provides continuous cycle operation. Offered in 700 and 800 bar max operating pressures with 4-8 L reservoir capacity, remote control pumps utilize heavy-duty bearings and have molded composite...

Read More »
Diaphragm Valves are rated for over 1 million cycles.

Diaphragm Valves are rated for over 1 million cycles.

Constructed of 316L Stainless Steel, MonelÂ-®, and HastelloyÂ-® C-276, D-Series diaphragm process analyzer system valves are available with hand wheel, Â-¼ turn, pneumatic, and Fieldbus-compatible electropneumatic actuation methods. Products come in standalone (tube or pipe), multi-stream manifold, and ANSI/ISA-76 compliant SMT models with working pressure range of vacuum to 3,600...

Read More »
Electronic Pressure Regulator features ATEX compliance.

Electronic Pressure Regulator features ATEX compliance.

Miniature Electropneumatic Type-550X converts variable signal to proportional pneumatic output. Built-in volume booster provides up to 20 scfm air flow capacity. Standard and zero-based units utilize input signal of 4-20 mA. Output pressure for standard range includes 3-15, 3-27, 6-30, 2-60, and 3-120 psig, while zero-based range outputs include 0-30, 0-60, and 0-120 psig. Regulator features NEMA...

Read More »
Flame Retardant Piping meets ICC fire code.

Flame Retardant Piping meets ICC fire code.

KynarÂ-® 740-02 polyvinylidene fluoride (PVDF) thermoplastic piping meets flame and smoke requirements developed by International Code CouncilÂ-® (ICC) for material use in building plenums. Available with 0/10 or 10/35 ASTM E84 rating, product exhibits resistance to most chemicals at room temperature in acid waste drainage applications and can handle elevated temperatures to 150Â-

Read More »
Interlocks feature interchangeable inserts.

Interlocks feature interchangeable inserts.

Providing accurate alignment of plastic mold halves, Series IN2(TM) INovative INterlocks utilize interchangeable inserts, eliminating need to replace entire side interlock set during maintenance. Graphitic steel inserts are held in place with interference-fit design that retains them when interlocks are installed on mold. There are no coatings, which could peel away under severe conditions.

Read More »
Spill Detection System works with syringe pumps.

Spill Detection System works with syringe pumps.

Able to detect spills and leaks down to as little as 3 drops of liquid, OS 250 consists of moisture sensing mat, connection between mat and controller, and switched power outlet. When moisture is detected, system sounds audible alarm, flashes LED, and turns off power of any device plugged into single outlet, solid-state power controller. Reusable mats measure 30 x 30 cm and can be cut to any size.

Read More »

Isolation Relay Modules suit access control applications.

Series 4804 four-relay modules operate on 12 or 24 Vdc and are DPDT-rated for 3 A at 24 Vdc with one common on each set fused at 1.6 A. Units include built-in fire alarm interface and mantrap interlock options. Wiring terminal strips with captive screw posts facilitate installation, while auxiliary terminal strip connections allow distribution of power from main input to other system devices....

Read More »
Pressure Piping Systems include 10 and 12 in. pipe sizes.

Pressure Piping Systems include 10 and 12 in. pipe sizes.

Available in 20 ft lengths, Schedule 80 PVC and CPVC Piping Systems feature chemical and corrosion resistance to acids, alkalis, and alcohols, making them suited for handling wide range of fluids. PVC and CPVC thermoplastic materials are lightweight and will not rust, scale, or pit. PVC systems offer temperature resistance up to 140Â-

Read More »
Automatic Pilot Valve provides safe lighting and shutoff.

Automatic Pilot Valve provides safe lighting and shutoff.

In cases where flame heating thermocouple is extinguished, H15 Series provides safe lighting of pilot and complete shut-off of main burner gas. It is available in sizes from 3/8 in. NPT to 1 in. NPT and can be used with natural or LP gas up to 0.5 psi. Offered in standard and high-temperature models, series is suited for commercial cooking equipment and other standing pilot applications.

Read More »

All Topics