Electrical Equipment & Systems

Pulsed Power Source suits orbital pipe welding.

Pulsed Power Source suits orbital pipe welding.

Model MPS-4000 microprocessor-based, portable inverter power source is designed for GMAW/FCAW process welding applications. Integral weld Head controller operates all Pipeliner weld Head models. Power source provides synergic control of electrode speed and power output. Factory-developed programs are stored for many combinations of alloy, electrode diameter, and shielding gas. Model MPS-4000 is...

Read More »
Dress Packs provide power, data, and media to robots.

Dress Packs provide power, data, and media to robots.

Fully-assembled Dress Packs, or umbilicals are protective polyurethane (PUR) jackets, which include components in any combination of hoses, control cables, and power cables. Hoses carry water, air, or oil. Electrical cables provide power to transformer/weld gun. Umbilicals allow user to protect entire cabling system from abrasion, weld sparks, and bending stress during robot operation. Posts,...

Read More »
Lamp Drivers provide lighting for PDAs and signage.

Lamp Drivers provide lighting for PDAs and signage.

Model D305 is capable of driving electroluminescent (EL) lamps as large as 100 cmÂ-² with high voltage AC output from 2.5 to 7.0 Vdc supply voltage. It is available in MSOP-10 package in tape and reel. Model D306A can convert 2.0 to 16.0 Vdc supply input to up to 400 V peak-to-peak AC signal that can drive EL lamps as large as 180 cmÂ-². It is available in surface-mount SOIC-16 with heat...

Read More »
PCB Terminal Blocks suit high amperage power applications.

PCB Terminal Blocks suit high amperage power applications.

Series 7572 rising cage terminal blocks are UL rated to 40 A, 150 V (VDE rated 57 A, 150 V). Two versions are offered: one with 2 solder pins per hole; and 3-pole version with 4 solder pins per hole. Each block provides 10.16 mm contact spacing to accommodate high amperage ratings for wire sizes 22-8 AWG. Clamping bodies consist of zinc-plated steel for connection integrity and polyamide 6.6...

Read More »
Multi-Colored Switch indicates operating condition.

Multi-Colored Switch indicates operating condition.

PCB-mounting Series 95 pushbutton can be illuminated with up to 3 different color LEDs. Able to change color when pressed, it maintains that color until pressed again. Available in 19 mmÂ-² versions and 12.7 mm versions, button's entire cap illuminates. Film insert can be inserted between diffuser and lens to mark function of each switch. Series 95 features noiseless switching action and...

Read More »
Motor provides improved heat dissipation.

Motor provides improved heat dissipation.

Based on ultrasonic standing waves, HR8EE Piezoelectric motors provide 25% more speed, force, and duty cycle than HR8 motor. HR8EE improves heat dissipation allowing for significant improvement to Envelope of Performance for use with advanced motion control and automation systems. Maximum speed increases to 350 mm/sec; maximum force increases to 45 N.

Read More »
Switchgear improves linemen safety.

Switchgear improves linemen safety.

KyleÂ-® VFI Vacuum Fault Interrupter pad-mounted switchgear with Visible-Break provides positive visual verification of contact status when distribution-switching procedures require indication of open circuit prior to testing and verification. Visible-Break feature is available in 2-position (open/closed) and 3-position (open/close/ground) configurations with ground switch capabilities. Unit...

Read More »
Digital Audio Cables are AES/EBU compliant.

Digital Audio Cables are AES/EBU compliant.

Digital Audio Snake Cables are 110 ohm cables available in constructions containing 2 to 24 pairs, and are UL-CM approved. Part No. SND2424 consists of 24 individually shielded and jacketed pairs with overall foil shield and jacket. It features 24 AWG conductors, foam polyethylene insulation, outer diameter of 1.20 in., and temperature rating of -30 to +75Â-

Read More »

Transmitters suit demanding applications.

Series TX1500 features 2-wire operation power, which is obtained directly from 4 to 20 mA loop, with no need for separate power input. Isolation to 1500 V rms eliminates possibility of electrical ground loops between signal source and receiver. Overvoltage of 120 Vac may be applied across input or output leads for 1 min in all models with voltage or thermocouple input. Reverse polarity of 400 Vp...

Read More »
3Sixty Mission Critical Launches New Service Offering UPS as a Service As A Cost Effective Alternative to UPS Equipment Ownership
Sponsored

3Sixty Mission Critical Launches New Service Offering UPS as a Service As A Cost Effective Alternative to UPS Equipment Ownership

At 3Sixty Mission Critical, we specialize in maintaining the performance and uptime of our customer's mission-critical applications. Our services are comprehensive and designed to take on the entire burden of maintenance. Our "UPS as a service" is just another example of how we develop out of the box solutions to help our customers operate more efficiently; see our video to earn more.

Read More »

All Topics