Magnifiers feature base with casters for mobility.

Suited for assembly and inspection shop floor, ProliteÂ-® Magnifiers with Roll-A-Round base can be instantly moved around when needed at another workstation or at different position for inspection. With 5-leg caster system, heavy-duty base is 32 in. high and includes heavy weight underneath for resistance to tipping. It is compatible with most magnifiers or other bench-mounted lighting...

Read More »

Interferometer System acquires data in as little as 1 msec.

PhaseCam(TM) 4010 dynamic Tywaman Green interferometer system acquires all information to compute phase in one exposure. Vibration-insensitive system includes one camera and optical phase sensor that eliminates need for phase shifters. Featuring Camera Link(TM) interface and single mode, HeNe laser that eliminates mode hoping, system measures moving parts and investigates their dynamic modal...

Read More »
Machine Vision Camera uses progressive scan technology.

Machine Vision Camera uses progressive scan technology.

To eliminate image jitter, IK-TF7A incorporates three 1/3 in. progressive scan CCDs in co-site sampling arrangement, which results in picture accuracy at resolutions to 1024 x 768 with no RGB shift. Variable-speed, electronic, 9-step shutter operates from 1/100-1/100,000 sec. Camera features readout speeds to 90 fps in partial scan mode, 30 fps full pixel independent readout, and one RS-232C port...

Read More »

Digital Camera utilizes firewire communications.

Suited for machine vision and industrial imaging, plug-and-play EC750 is available as monochrome or color camera with global shutter, near-IR performance, and automatic controls. Backplane provides IEEE-1394 port and 4-pin Hirose connector for external triggering. At full 752 x 480 resolution, DCAM-compliant camera is capable of 60 fps. Included software consists of ProViewer application, camera...

Read More »

Network Camera acquires images in all lighting conditions.

Built around ARTPEC-2 video compression chip, AXIS 221 Day and Night Network Camera utilizes Pentax lens and progressive scan CCD image sensor. It also offers power over Ethernet and built-in video motion detection as well as simultaneous Motion JPEG and true MPEG-4 full frame rate video streams. Suited for surveillance in indoor and outdoor environments, camera takes color video when there is...

Read More »
Low Pass SMT Filter suits RF and microwave applications.

Low Pass SMT Filter suits RF and microwave applications.

Measuring .442 x .184 x .030 in., S Band 2.4 GHZ planar surface mountable thick film filter features passband up to 2,500 MHz with passband ripple of .01 dB. Second and third harmonic rejection is 25 dB min, and VSWR is 1.1:1. Compact unit, which incorporates 5 sections with 50 ohm input and output, is suited for applications such as wireless local area networks, microwave communication links,...

Read More »
Radiometer/ Photometers provide research-grade precision.

Radiometer/ Photometers provide research-grade precision.

Model OL 730C features internal amplifier and sensitivity of 1 x 10-14 A. Virtually controlled via user's PC, Model OL 730CV boasts response time as fast as 0.1 sec with full-scale range of 2 x 10-10 to 2 x 10-3 A. Utilizing digital signal processing, Model OL 730D is capable of measurements over all or part of UV/VIS/IR spectrum and has photon counter for extremely low light level measurements.

Read More »
Microscope offers non-contact 3D material analysis.

Microscope offers non-contact 3D material analysis.

Confocal Laser Scanning Microscope, Model LSM 5 PASCAL includes functions for quantitative surface analysis and characterization such as roughness and volumetric measurement as well as bearing ratio analysis. Units are available with Axio Imager MAT upright stand or Axiovert 200 MAT inverted stand. Both can employ piezotechnology for precise measurements of nanometer-scale height steps. StitchArt...

Read More »
TEDS PDA Reader/Writer has portable design.

TEDS PDA Reader/Writer has portable design.

Using PDA device, Model 400A87 enables reading and writing to IEEE 1451.4 compliant TEDS transducers. User can display contents of transducer's TEDS memory chip and write user-specific information to memory chip. Entire transducer data sheet in displayed in full detail, and transducer sensitivity can be displayed in SI or English units. Unit supports templates for IEEE P1451.4 v0.9 and v1.0, as...

Read More »
Dye Laser offers narrow linewidth and high spectral purity.

Dye Laser offers narrow linewidth and high spectral purity.

With tuning range of 320-860 nm, ScanMatePro(TM) pulsed dye laser features plug-in, bandwidth-reduction optics that allow continuous scanning at linewidth of less than 0.08 cm-1 across tuning range of any dye. Unit is also available with etalon scanning, enabling hands-free wavelength scanning at 0.03 cm-1. Output is characterized by high spectral purity, with total amplified spontaneous emission...

Read More »

All Topics