Modules

Modules provide direct AC input for sensor applications.

Modules provide direct AC input for sensor applications.

Ricos modules allow direct AC input for any sensor/initiator applications required to use AC at 115V or 230V. They enable 4 inputs in 1 unit. When used in conjunction with buscoupler, AC expansion modules have local force, lock, and trigger diagnostic features. Compatible with Profibus-DP, Interbus-S, DeviceNet, Ethernet and CANopen protocols, modules offer test points at each termination point,...

Read More »

Communications Interface operates using Java applet.

WebView I/O, WVC16 Communications Interface module allows users to view process data on near real-time basis, perform data logging functions on specified modules, calibrate signal conditioners remotely, and view diagnostic information. It can communicate with up to 32 WebView I/O modules by means of its internal infrared communications link, and will notify up to 10 people by e-mail when out of...

Read More »

I/O Modules interface with DeviceNet(TM).

16-channel POINTBlock I/O Modules, with 60 mm footprint, including DeviceNet interface, include 120 Vac 1734D-IA16 and 1734D-IA16S, and 24 Vdc 1734D-IB16 and 1734D-IB16S. All have sequential auto addressing for simplified commissioning of expansion modules; protected outputs with option of latching off or pulse retry configuration; I/O messaging options for optimized I/O memory and network...

Read More »
RTD Input Modules connect to Modbus.

RTD Input Modules connect to Modbus.

Dual/quad-channel BusWorks(TM) 930MB Series I/O captures data from up to 4 RTD temperature sensors or resistance input signals for communication over Modbus network. It has 4 built-in solid-state relays for independent local alarms or on/off switching functions. Setup is via Windows(R) configuration software for selection of input/output ranges, limit alarms, and other operating parameters....

Read More »
Design & Manufacturing Process of a Coil
Sponsored

Design & Manufacturing Process of a Coil

Because the design and manufacturing of electromagnets are critical to the successful operation of the application, it's important to spend time defining your requirements before purchasing coils for an application. This eBook will guide you through the process of evaluating the application's constraints, identifying the needed specifications, and collaborating with a manufacturer to develop an appropriate coil solution for the application.

Read More »
I/O Modules offer sequential auto addressing.

I/O Modules offer sequential auto addressing.

POINTBlocks integrate DeviceNet(TM) interface with array of 16-point I/O starter blocks. One- to four-channel POINT I/O(TM) modules can be snapped to base for expansion up to 264 I/O points. Modules provide protected outputs with option of latching off or pulse retry configuration, I/O messaging options, gold alloy contacts to facilitate low voltage applications, vertical and horizontal mounting,...

Read More »
Interface Module connects USB to GPIB.

Interface Module connects USB to GPIB.

Model 488-USB converts desktop or portable PCs with USB interface into full-function, IEEE 488.2 GPIB compatible bus controller. Module plugs onto any open GPIB connector, such as open end of cable stack, on back of instrument, or unused connector on company's GPIB BusStrip(TM). Finger size jackscrews secure and hold module in any position. Applications include controlling instruments, collecting...

Read More »
I/O Terminal Block connects to DeviceNet bus system.

I/O Terminal Block connects to DeviceNet bus system.

Brick-style RIO remote terminal block includes base module and plug-in, DeviceNet, electronic module. Terminal strips on base module accommodate 2- and 3-wire field devices, such as sensors and actuators. Additional I/O may be added with analog and digital expansion module terminal blocks. Base module can be snapped onto DIN rail or panel mounted. Module is available with either screw-clamp or...

Read More »
I/O Interface conforms to SEMI-S2 safety requirements.

I/O Interface conforms to SEMI-S2 safety requirements.

Model CDN127 digital peripheral device interface supports 8 fail-safe digital inputs/outputs, 2 analog inputs, 2 analog outputs, and electromechanical relay interlocks. Module converts non-DeviceNet(TM) peripheral devices to DeviceNet. CDN127 operates as Group 2 slave on DeviceNet network. Device Profile for CDN127 is based on DeviceNet Vacuum Dry Pump Device Profile, Revision 1.7.

Read More »
Clock Data Modules suit SONET OC-192 applications.

Clock Data Modules suit SONET OC-192 applications.

M830/831 series CDR modules regenerate spectral component from incoming NRZ data stream, and output low jitter clock and retimed complementary data. Typical data output jitter at 12.25Gb/s is less than 8ps p-p, making them suitable for SDH system applications. Modules use phase-lock loop architecture and high stability, low-nose SAW VCO to provide low jitter clock and data outputs. Series is...

Read More »
I/O Modules provide industrial control.

I/O Modules provide industrial control.

POINT I/O(TM) Modules offer options for digital, analog, thermocouple and RTD control applications. Networking interfaces can be snapped together to meet exact needs. Modules have gold-plated backplane, wire-off indication and point-level diagnostics. Analog modules provide interface to analog voltage field devices located more than 20 ft from system controller. Thermocouple and RTD modules each...

Read More »

All Topics