RTD Input Modules interface sensors to Profibus network.

RTD Input Modules interface sensors to Profibus network.

BusWorksÂ-® 966PB interfaces up to 6 RTD or resistance signals directly to Profibus-DP network. Each module contains 16-bit A/D converter, microcontroller for intelligent signal processing, and SPC3 ASIC to communicate with network. Ranges are user selectable for platinum, nickel, or copper RTD sensors and 0-500 ohm signals. Three-way 1,500 Vac isolation between input, network, and power...

Read More »
I/O Modules do not degrade Wavebook measurement bandwidth.

I/O Modules do not degrade Wavebook measurement bandwidth.

Models WBK40(TM) and WBK41(TM) provide measurement capabilities for Ethernet-based 1 MHz WaveBook/516E(TM) by adding up to 224 thermocouple inputs. WBK40, 14-channel thermocouple modules have on-board, 16-bit, 200 kHz A/D converters that measure TC inputs synchronously with WaveBook's 1 MHz measurements. Multifunction WBK41 modules, similar to WBK40 modules, include 14 thermocouple inputs, but...

Read More »
PC/104 Module includes 8 serial I/O ports.

PC/104 Module includes 8 serial I/O ports.

Model PCM-COM8 8-channel, serial asynchronous communications module provides each transmit and receive channel with 128-byte deep FIFO. All 8 channels support RS-232, RS-485, and RS-422 electrical levels to interface to serial communications devices. Two XR16C854 devices serve as serial communication controllers and contain on-chip, software programmable baud rate generators with data rates...

Read More »

AC Outlet Power Module is offered in two versions.

IMACP AC Voltage Power Outlet Module, available in single outlet and duplex outlet versions, accepts up to 12 AWG wires and is rated at 15 A at 125 Vac. Unit incorporates stabilized AC outlet socket, terminal blocks, finger safe connections, and modular DIN rail mounted design. Applications include use in equipment cabinets, panels, and in systems where power may be required for laptops, test...

Read More »
Analog I/O Modules offer HART protocol.

Analog I/O Modules offer HART protocol.

Designed for seamless compatibility with ControlLogix(TM) and Experion PKS(TM), 8-channel modules provide full analog capability and HART (highway addressable remote transducer) Protocol. Products maximize I/O performance by combining real-time HART data acquisition with analog acquisition and control. As HART master, modules allow communication with HART field devices, which may be interfaced...

Read More »
Bus Coupler is CC-Link compatible.

Bus Coupler is CC-Link compatible.

CC-Link Buscoupler 750-310 allows connection of high-density digital, analog, and special function I/O to system. It utilizes 2 selector switches to address node. Third selector switch is used to set 5 different baud rates from 156 Kbps to 10 Mbps, and 2 address modes including fixed and auto. Coupler offers connection of up to 64 I/O modules, max bus line distance up to 1200 m, and max I/O...

Read More »
I/O Module suits remote data acquisition applications.

I/O Module suits remote data acquisition applications.

Model RIO-24 digital I/O solution offers 24 bits in any combination of inputs or high-current outputs. Housed in steel enclosure, it interfaces to controlling computer through wireless link, USB converter, or RS-232 port via RS-485 converter. Outputs sink up to 350 mA each, or switch between 0 and 5 Vdc. Windows-based application allows for establishing communication, quick setup, and testing of...

Read More »
Color Graphic Module provides indoor/outdoor readability.

Color Graphic Module provides indoor/outdoor readability.

Featuring vivid colors with 640 x 240 dots of resolution, AGM6424B series offers high brightness CCFT back lighting for outdoor and indoor viewing. PCB board is encased by Bezel for safe handling and installation. Module size is 173.0 x 73.0 x 7.0, and viewing dimensions are 156.0 x 60.0. Applications include price scanners, POS terminals, meters, gas pumps, gaming machines, video Games, vending...

Read More »

Mezzanine Module operates at sampling rates up to 105 MHz.

Model 6236 Velocity Interface Mezzanine module is based on Model AD6645-105 14-bit monolithic A/D converter. Two-channel VIM-2 board features configurable XC2V1000 or SC2V3000 FPGA. Both A/D converter outputs are connected directly to FPGA to facilitate compute-intensive signal processing functions. FPGA can deliver wideband A/D data or processed results directly to processor board through dual...

Read More »

I/O Module interfaces between logic circuitry and load.

Model G3TC features built-in hold down screw, which fastens relay to board to eliminate loosening by vibration. AC input module's operating voltage is 90-140 Vdc/ac and 180-280 Vdc/ac, while DC input module's range is 10-32 Vdc/ac. Logic level output supply voltage is 5-24 Vdc on both input modules. AC output module's applicable load is 3 A @ 75-280 Vac depending on model. Input voltage is 5-24...

Read More »
Sentry Equipment Introduces New Compact Hygienic Automatic Sampler
Sponsored

Sentry Equipment Introduces New Compact Hygienic Automatic Sampler

As a leader in industrial sampling equipment at Sentry Equipment, our success is built on a history of innovation and designs that epitomize value and efficiency. The new Hygienic Automatic Sampler is another example of our dedication to developing quality engineered products. To learn how this product can streamline the sampling process for dry, free-flowing materials, see our new video.

Read More »

All Topics