Modules

Analog Output Modules deliver fast waveform output for PCI.

Analog Output Modules deliver fast waveform output for PCI.

PCI-6731 and PCI-6733 have 4 and 8 analog output channels, respectively, and deliver 1 MS/sec per channel, 16-bit, analog waveform outputs. Both have 2 counter/timers, software-controlled onboard timing signal routing, and connect to company's instrumentation, data acquisition, motion, and vision products. DAQT(R) 6.9 driver software interfaces to LabVIEW(TM), LabWindows(TM)/CVI, and Microsoft...

Read More »

I/O Cards provide zone control.

1799-ZCIOV (sinking output) and 1799-ZCIOB (sourcing output) modules include Zone Interlocking Protocol, a parameter-based technology that allows 1 card to consume data directly from up to 4 other ZCIO cards, providing response time of 2 msec. ZCIO cards are designed for applications where machine provides enclosure for I/O or where I/O board fits into field replaceable unit. DeviceNet(TM) is...

Read More »

Modules and Controller connect I/O to Ethernet Powerlink.

System 2003 modules can be integrated in Powerlink network. With Ethernet Powerlink, cycle times of 400 microseconds with maximum network jitter of less than 1 microsecond are possible. By using EX481 bus controller and 2003 modules, physically synchronized output behavior can be achieved on multiple I/O stations on network. Ethernet connection is made via RJ45 connector.

Read More »

Transmitters convert analog input signals to digital data .

DIN-100 Sensor to Computer Modules transmit data via RS-485 to controller, which may be computer or other processor-based equipment. Modules measure temperature, pressure, voltage, current, digital input, or digital output signals. They perform all signal conditioning, scaling, linearization, and conversion to linearized ASCII data values or Modbus RTU data values. Address, baud rate, parity, and...

Read More »
Fieldbus Coupler fits CANopen systems.

Fieldbus Coupler fits CANopen systems.

IL CAN BK bus coupler operates at any position in CANopen network. It uses diagnostics element to send detailed failure cause and location data to master, where they can be evaluated by appropriate software. Diagnostics and status displays enable exact module fault location and on-site determination of cause. Coupler supports analog and digital I/O, special function I/O, Category 4 Safety relay...

Read More »
Analog Splitter divides transmitter signal.

Analog Splitter divides transmitter signal.

MCR splitter takes signal from transmitter and sends two identical or different signals to receiving devices for monitoring, recording, or control. Input and two output ranges can be selected via DIP switches. Selectable analog signal ranges include 4 to 20 mA, 0 to 20 mA, 0 to l0 mA, 0 to l0 V, 0 to 5 V and 1 to 5 V. All analog range options are pre-configured and stored, eliminating need for...

Read More »
Relay Module takes up little rack space.

Relay Module takes up little rack space.

Slim MICROSERIES is less than 1/4 in. wide, requires very little space on TS35 DIN rail, and offers choice of screw or tension clamp connections for wires up to 14 AWG. Module has release mechanism that secures relay safely and reliably on socket base, with eject function for quick release when servicing is required. Relay modules operate on nominal coil voltages of 5, 12, 24, 48, and 60 Vdc, 24,...

Read More »
Relay Output Module clips onto microPLC.

Relay Output Module clips onto microPLC.

RO108M attaches to side of Series T1-16S microPLC and can switch/control 100 to 240 Vac or 5 to 24 Vdc. Each T1-16S accommodates up to 5 relay output modules. TRO108M can be used wherever it is necessary to have relay contact switch ON/OFF in control circuit. It allows T1-16S to control, alarm, or monitor based on system conditions, including: Turn ON/OFF motors, solenoids, or interposing relays;...

Read More »
Instruments provide height and level measurement.

Instruments provide height and level measurement.

Z-Cal 600 XT Height Gage offers 24 in. range and 2D (X-Y) software capability. It requires low measuring force and features motorized movement, full numeric keypad, and air-bearing base. Wyler Radio Module for Minilevel/Levelmeter NT 2000 provides error-free data transmission over long distances without connecting cables. This allows measurement of big structures such as large machine tools,...

Read More »
I/O Card suits PC/104-based data acquisition.

I/O Card suits PC/104-based data acquisition.

Model 104-DIO-48S, 48-bit, parallel, digital input/output card operates in temperatures from 0 to 65 deg C. 48-channel board offers Change of State (COS) detection, determines data in one READ, and contains 2 type 82C55A Programmable Peripheral Interface chips (PPI). Each PPI provides two 8-bit ports on A and B and two 4-bit ports on C. Each of its 48 I/O lines is buffered and capable of sourcing...

Read More »

All Topics