Module provides HART multi-drop communication.

Model MV156-HART provides 4 independent HART communication channels for Allen-Bradley's ControlLogix platform. HART channels generate signal to communicate in multi-drop mode enabling 2-way communication between processor and field transmitter. Module operates as master, supporting 15 instruments per channel with full configurable read/write access to instrument configuration/diagnostic tables....

Read More »

Modules connect processors to serial protocols.

In-chassis MV169 protocol conversion modules connect Allen-Bradley's 1769 CompactLogix processors with networks such as DF1, Modbus, ASCII, DNP 3.0, IEC60870, and C programmable. Modular solution provides backplane compatibility, 2 isolated serial ports with one debug port, and 57.6K baud rate. Serial ports allow connectivity to RS-232/422/485 devices and networks, enabling greater interface...

Read More »
CMOS Serial Link increases backplane port density.

CMOS Serial Link increases backplane port density.

Model TLK6B008 enables 6 Gbps transmission over legacy system that run up to 3 Gbps. It has eight 6.25 Gbps bi-directional serial data channels on sharp end and sixteen 3.125 Gbps channels on blunt end, providing 100 Gbps data throughput. Receiver uses 4-tap adaptive DFE receive equalizer technology, including cancellation of first post cursor. Transmitter uses 4-tap equalizer with fully...

Read More »

Modules enable deployment of C applications.

Series MVI-ADM allows users to develop C applications that operate on Allen-Bradley's ControlLogix, PLC, SLC, and FLEX I/O platforms. Programmable units feature 3 serial ports, 2 of which are isolated for field interfaces supporting RS-232, RS-422, and RS-485. Two ports are jumper configured for direct or multi-drop field communication and 1 port is for module setup and diagnostics. Memory...

Read More »

Variable Speed Drive features swinging choke technology.

Model ACS550 precisely controls motor speed to reflect actual demand, eliminating waste caused by fixed-speed operation. Swinging Choke reduces harmonics at both full and partial loads. Standard Start-Up Assistant software guides user through set-up procedures, while Maintenance Assistant signals when it is time for routine maintenance. Diagnostic Assistant provides suggestions for correcting...

Read More »
Touch Screen Control supports simple pick list processing.

Touch Screen Control supports simple pick list processing.

With PL-C Touch Screen Control, pick list can be entered into storage and retrieval system or downloaded from host computer. Pick list is created by keying in each part number and associated quantity, by scanning list using optional integrated scanner, or by importing pick list from host system. Line item is highlighted on control if there is not sufficient stock to fill order. Single PL-C...

Read More »
Filtered Power-Entry Modules handle up to 20 A.

Filtered Power-Entry Modules handle up to 20 A.

Series EEJ features 20 A filter, attenuating 48 db at 30 Mhz in common mode for non-medical versions. Various terminations and installation types are available. Units have UL/CSA/VDE agency approvals and are suited for computer workstations, networking equipment, telecom-datacom equipment, medical devices, test and measurement devices, fitness equipment, and other industry applications.

Read More »
Wireless I/O System is housed in NEMA 4X enclosure.

Wireless I/O System is housed in NEMA 4X enclosure.

Housed in cast aluminum enclosure, N4ANT ruggedized wireless I/O transmitter/receiver system suits industrial, commercial, or general-purpose areas rated NEMA 4X. Aluminum enclosure is impact-resistant to UL requirements, and glass that protects antenna does not interfere with signal strength. Features include 1 W transmitter power, 4-20 mA analog signal, 3 contact outputs rated 120 Vac @ .05 A,...

Read More »
I/O Modules extend functionality of Power Meter 800.

I/O Modules extend functionality of Power Meter 800.

By linking analog and digital I/O inputs to single PowerLogicÂ-® PM800 device, users can oversee transformer temperatures, generator fuel levels, equipment status, or usage of utilities such as water and steam. Model PM8M2222 provides 2 digital outputs, 2 digital inputs, 2 analog outputs, and 2 analog inputs, while Model PM8M26 provides 2 digital outputs and 6 digital inputs. Plug-and-play...

Read More »
Controller integrates HMI capabilities.

Controller integrates HMI capabilities.

Comprised of HMI, processor/power supply, and I/O modules, Pico GFX-70(TM) supports analog and digital I/O, and performs simple logic, timing, counting, and real-time clock operations. With integrated, backlit, 70 mm, monochrome LCD display, users can program control and HMI functionality with one software package or on-display buttons. Display shows text, date and time, and custom messages and...

Read More »
Krueger Sentry Gauge Announces the Release of Two New Chemical Sight Gauge Models Designed for Aggressive Liquid Storage Monitoring
Sponsored

Krueger Sentry Gauge Announces the Release of Two New Chemical Sight Gauge Models Designed for Aggressive Liquid Storage Monitoring

Krueger Sentry Gauge, a leader in chemical sight gauges, now offers the ultimate in aggressive liquid storage monitoring devices. From sulfuric and hydrochloric acid to bleach, and acetone, our products are designed with robust features that deliver a long and trouble-free service life. See our video to learn all about this new and innovative line of sight gauges.

Read More »

All Topics