I/O Devices and Timing Boards offer channel-channel isolation.

I/O Devices and Timing Boards offer channel-channel isolation.

Model PCI-6528 and CompactPCI/PXI-6528 digital I/O devices feature up to 60 Vdc range on inputs and outputs, 5 V logic thresholds, and isolated input/output to PXI trigger bus. They include programmable power-up states, digital I/O watchdogs, change detection, and programmable input filters. Model PCI-6624 counter/timer board features 48 Vdc range and 5 V logic thresholds, as well as isolation to...

Read More »
Touchscreen HMI Panels Web-enable up to 5 serial protocols.

Touchscreen HMI Panels Web-enable up to 5 serial protocols.

Equipped with up to 5 communication ports, Crimson 2 software, and built-in gateway, G3 HMI Series operator panels Web-enable multiple devices, including PLCs, PCs, drives, and PID controllers. They deliver remote access, monitoring, and virtual operation via company LAN or Internet, facilitating real-time operational access and data logging from remote PC. Features include USB, RS422/485, and...

Read More »
Dual Voltage DC Drive includes speed and torque controls.

Dual Voltage DC Drive includes speed and torque controls.

Capable of operating in speed or torque control mode, MM23002D series dual voltage drives are available in NEMA 1 and 4X models with wired and mounted operators and switches on front cover and AC line fuses inside. User-selectable inhibit modes enable users to choose whether inhibit function is activated by NO or NC condition. Jumper selects whether inhibiting directs motor to min speed or stop....

Read More »
Isolated DC Drive can control DC motors up to 2 hp.

Isolated DC Drive can control DC motors up to 2 hp.

Housed in NEMA 4X enclosure, Patriot Model MC10-PCM accepts any 0-10 V or 1-5 mA reference signal. Shunt resistor terminals are provided in case 4-20 mA or other current signal is to be used. Drive includes power and current limit LEDs, line fuses, and inhibit pins for remote start/stop control. Mounted on cover is speed adjust knob, on/off switch, and manual/signal switch. Drive has 1% speed...

Read More »
Electronic Governor facilitates smooth engine operation.

Electronic Governor facilitates smooth engine operation.

Electronic Governor incorporates electronic and mechanical functions in integrated system. Electronic module processes engine speed information and sends appropriate signals to stepper motor on carburetor throttle shaft. Unit dictates movement of throttle with steps as small as 0.2-°. It eliminates droop experienced while engine is under load, and can automatically adjust spark timing. Governor...

Read More »

System-on-Modules provide power and thermal management.

Based on IntelÂ-® PentiumÂ-® M processor and 855GME chipset, Plug-N-Run G3 System-on-Modules have controls that allow OEMs to build power and thermal protection schemes for extended time-between-recharging in mobile equipment. They also aid in careful management of performance vs. dissipation in high-density systems. Controls, accessible through BIOS setup, are used to configure operating...

Read More »
Positioning Units deliver automation to laser experiments.

Positioning Units deliver automation to laser experiments.

Minature NewStep(TM) NSA12 Actuator enables motorized control of translation stages and mechanically adjustable mounts. Measuring 60 x 30 mm, unit provides up to 11 mm travel with sub-micron incremental motion. NewStep(TM) NSC100 Controller offers both manual and computer control via RS232. Multi-functional manual knob controls motor speed, and initiates home searches and computer control....

Read More »

MCUs are available with 5 or 10 kB RAM.

Offered in 64-pin quad flat package, MSP430F161x products have 5 or 10 kB RAM depending on model. They employ 200 ksps multi-channel 12-bit analog-to-digital converter, two 12-bit digital to analog converters, and 2 serial ports. Other features include I2C peripheral, hardware multiplier, 10 PWM channels, and 32-55 kB in-system programmable Flash combined with autonomous 3-channel direct memory...

Read More »
Plug-and-Play I/O Modules offer monitoring capabilities.

Plug-and-Play I/O Modules offer monitoring capabilities.

Power Meter 800 I/O modules are available in 2 models: PM8M2222 provides 2 digital outputs and inputs and 2 analog outputs and inputs, while PM8M26 provides 2 digital outputs and 6 digital inputs. By linking several analog and digital I/O inputs to one PM800 device, users can oversee transformer temperatures, generator fuel levels, equipment status, or usage of utilities such as water and steam.

Read More »
Modular Drives offer 98% operating efficiency.

Modular Drives offer 98% operating efficiency.

Models VLT 5122/5302 are 90-200 kW, 125-300 hp drives are available with built-in RFI performance to EN 55011 class B. Power termination design accepts single box lug or dual cable legs. Logic routing includes tie-down provisions to simplify installation and protect against noise disturbance. Ambient temperature ratings are 40-45Â-

Read More »

All Topics