PXI Module integrates PXI platforms in DAQ systems.

PXI Starter combines 3U, 8-slot chassis featuring 7 PXI peripheral slots and 400 W ATX power supply with PCI-PXI extension kit. Power supply, temperature, and cooling fans are monitored by built-in alarm in chassis. Warning LED and alarm are activated if failure is detected. PCI-PXI Extension Kits work as transparent PCI-PCI bridge register set and provide direct control of PXIS-2630 chassis from...

Read More »

Power Modules feature NEBS-compliant design.

Rated at 1.6-2.3 kW, POWERCACHEÂ-® ultracapacitor-based, 48 V backup power modules provide maintenance-free alternative to batteries for short-term bridge power in UPS systems. Modules stay fully charged and recharge in seconds in case there are multiple grid power interruptions. Rack-mount units are suited for telecommunications, industrial, and medical applications.

Read More »
Switch Modules suit measurement and automation applications.

Switch Modules suit measurement and automation applications.

PXI-7900 Series switch modules are PXI Rev. 2.1 and PICMG 2.1 R 2.0 CompactPCI hot swap compliant and can be used in either PXI or CompactPCI systems. Series includes PXI-7901 16-ch general-purpose SPDT relay module, PXI-7921 24-ch 2-wire multiplexer module, and PXI-7931 4 x 8 2-wire matrix module. Each switch module series features distinct functionality to cover needs of variety of applications...

Read More »

I/O Products include digital diagnostic and analog modules.

FLEX modular I/O products include 1797-IE8H HART and 1797-OE8H HART, respective 8-point input and output HART analog modules that allow for communication with smart field devices that support HART protocol. FLEX I/O digital diagnostic modules allow control system user to identify operating conditions that may result in system failure. FLEX I/O also offers conformal coating that consists of 1-2 mm...

Read More »
Analog Input Module provides detailed status information.

Analog Input Module provides detailed status information.

Used with 2005 controller, Model AI780 features 8 analog inputs with 16-bit resolution for current signals ranging from 0-20 mA. Inputs are electrically isolated from one another, and each measuring channel has separate electrically-isolated sensor power supply. Measurement signals can be converted either in continuous conversion mode which runs independently of application, or by converting all...

Read More »
Power Packs suit hydraulic drive applications.

Power Packs suit hydraulic drive applications.

Standard, fixed displacement Power Packs feature output range from 2Â-½-20 gal units, providing 0.4-10 gpm fixed flow up to 3,000 psi. Rated 0.5-20 hp, motors are standard TEFC, 1,750 rpm, 3-phase units. Standard, variable displacement Power Packs are available in 20-100 gal units with 4.2-31 gpm variable displacement up to 3,000 psi. Also available in 2-50 hp, products incorporate...

Read More »
PCI DI/DO Cards offer 128 digital input/output channels.

PCI DI/DO Cards offer 128 digital input/output channels.

Models PCI-1758UDI and PCI-1758UDO are digital input/output cards with universal PCI bus, BoardID(TM) switch, and high-voltage isolation. PCI-1758UDI has interrupt function for each of 128 digital input channels and digital filter function, which provides de-bouncing for switches and relays. PCI-1758UDO features watchdog timer and user-configurable power-up states. Both cards support systems with...

Read More »

Modular Platform Standard suits automated test systems.

LXI Standard combines built-in measurement science and PC-standard I/O connectivity from rack-and-stack instruments with modularity of cardcage-based systems. LAN connectivity enables modules to reside and be accessed anywhere worldwide. Available in full or half width, self-contained modules include processor, LAN connections, power supply, and trigger inputs. Controlled by computer, modules use...

Read More »
Process Control System offers MODBUS RTU communications.

Process Control System offers MODBUS RTU communications.

NET ConcentratorÂ-® System Process Control and Distributed I/O Network is available with RS-485 communication capabilities. This enables system to use twisted wire pair, Ethernet, wireless (RF), fiber, and telephone modem data links to send monitoring and control signals over long-distance and in hazardous environments. System features 20-bit measurement resolution, signal conditioning...

Read More »
Digital Output Modules include fail-safe function.

Digital Output Modules include fail-safe function.

Models ADAM-4056S and ADAM-4056SO are 12-channel sink and source type, isolated digital output modules with communication watchdog, support for Modbus RTU protocol, and fail-safe function that resets outputs to predefined values. Model ADAM-4056S offers max load of 200 mA making it suitable for devices having sink type digital inputs, while Model ADAM-4056SO provides 1 A per channel, making it...