Flue-Gas Analyzer offers data logging and integral printer.

Flue-Gas Analyzer offers data logging and integral printer.

Lancom III measures COlow, CO high, O2, NO, NO2, NOx, SO2, H2S, CO2 and hydrocarbons. It calculates combustion efficiency, loss, excess air, CO2, and total NOx and provides measurement corrections such as oxygen normalization, wet or dry analysis, and automatic reading conversions. Insight software allows data capture, storage, analysis, and presentation of measurement information in...

Read More »
Pressure Analysis System supports up to 10,240 sensors.

Pressure Analysis System supports up to 10,240 sensors.

Model T3000 turnkey tactile pressure measurement system enables real-time analysis of objects in direct physical contact. WindowsÂ-®-compatible software converts raw sensor data into color-coded, 3D representation of pressures on irregularly shaped objects. Scalable system delivers out-of-the-box data collection with parallel-scanning architecture and capacitive sensing technology. It...

Read More »
Measuring Receiver System calibrates RF signal generators.

Measuring Receiver System calibrates RF signal generators.

Model N5530S is based on company's PSA Series spectrum analyzers and EPM/EPM-P power meters. Standard frequency coverage of 3 GHz is provided. Measurements up to 26.5 GHz can be performed without external downconverters. Unit offers minimum RF bandwidth of 1 Hz and 160 different bandwidths. It has integrated demodulation distortion measurement capability. System has 3 sensor modules; option 504,...

Read More »

Gas Monitor detects toxic chemicals and warfare agents.

Model ppbRAE Plus detects volatile organic compounds in concentrations of 1 part per billion. Photoionization feature extends its upper detection range from 200 parts per million up to 2,000 parts per million. Unit has self cleaning lamp and sensor to minimize need for maintenance and calibration, and resists moisture and dirt. More than 100 built-in correction factors enable unit to measure over...

Read More »
High Resolution Columns are designed for organic GPC.

High Resolution Columns are designed for organic GPC.

PlusPore series columns, designed for high resolution organic gel permeation chromatography (GPC), are made using polymerization process to produce particles which exhibit specific, controlled pore structure. Multi-pore structures have pore volume compared to PS/DVB packing materials and offer chemical and physical stability. They permit transfer across full range of organic solvents with little...

Read More »
Air Analyzer enables atmospheric particulate monitoring.

Air Analyzer enables atmospheric particulate monitoring.

Model 5020 Sulfate Particulate Analyzer supports need to measure ultra-low pollutant concentration levels in complex urban environments. System enables direct and automatic measurement of background air and produces near real-time data for improved monitoring programs. Analyzer features on-site setup and operation.

Read More »
Particle Size Analyzer offers wet and dry measurement.

Particle Size Analyzer offers wet and dry measurement.

Using optical system and single light source, SALD-3101 Laser Diffraction Particle Size Analyzer measures coarse or dense particles ranging from 0.05-3,000 Â-µm. Sampler incorporates vertical radial pump with flow rate of 5,000 cmÂ-³/min to circulate particles. Optional SALD-DS21 Injection Type Dry Measurement Unit allows for switching between wet and dry samples. Users can choose from 3...

Read More »

Welding Enclosures provide freedom of movement.

To facilitate welding of stainless steel, titanium, and exotic or reactive metals, ArgweldÂ-® Flexible Welding Enclosures enable users to manipulate workpiece and welding torch to work closer to workpiece. Product also allows precise monitoring and control of atmosphere around torch and weld pool. Available in diameters of 900-1,800 mm, enclosures are equipped with 2 pairs of glove ports and...

Read More »
NO/NOx Analyzer uses chemiluminescent principle.

NO/NOx Analyzer uses chemiluminescent principle.

Model 300 CLD Analyzer continuously measures total concentration of oxides of nitrogen within gaseous sample. Method is based upon chemiluminescent reaction between ozone and nitric oxide (NO) to form nitrogen dioxide and oxygen. Features include 8 switch selectable ranges from 0-3 ppm to 0-10,000 ppm NO/NOx, critical flow orifice flow control, and digital diagnostics.

Read More »
Fresh Air Intake Designed to Meet ASHRAE 62.2 standards
Sponsored

Fresh Air Intake Designed to Meet ASHRAE 62.2 standards

Alan Manufacturing has a long history of developing innovative solutions for HVAC applications. With over 1,000 product designs under our belt, we have gained a reputation as the go-to source for HVAC dampers, hardware, duct supports, zone control systems, and much more. Adding to this extensive list of achievements we now announce the release of our new line of Fresh Air Intake products. Designed to meet ASHRAE 62.2 standards, they are the most robust and high-performance product of their kind. See our video to learn more.

Read More »

All Topics