Switching Regulator features low 100 -µA quiescent current.

Switching Regulator features low 100 -µA quiescent current.

Model LT1976EFE step-down regulator operates within input voltage range of 3.3-60 V. Internal 1.5 A, 0.2 ohm switch delivers up to 1.25 A of continuous output current to voltages as low as 1.25 V. Combination of thermally enhanced TSSOP package and 200 kHz switching frequency keeps external inductors and capacitors small. Unit includes power good flag with programmable threshold and time-out. It...

Read More »
Heavy Duty Lifters are powered by 63 mm ISO/VDMA cylinder.

Heavy Duty Lifters are powered by 63 mm ISO/VDMA cylinder.

Series PHL Heavy Lifters are offered in stroke lengths of 50, 80, 100, 125, 160, and 200 mm. Cylinder has adjustable cushions, which reduce shock to unit, and magnetic piston for switches to provide end of stroke signal to controllers. Built-in rod compliance eliminates side load on cylinder piston. Composite bearings are internally lubricated. Able to handle off-center loads, lifters are suited...

Read More »
Control Indicator Module contains SCADA interface.

Control Indicator Module contains SCADA interface.

Control Indicator Module provides remote control and monitoring of up to 3 power circuit breakers and reclosers. RS-485 interface allows use of DNP 3.0, Modbus, or other compatible communications protocols. Unit accepts signals from protective relays and can be used online with up to 32 separate computer workstations and printers. LEDs indicate breaker trip coil operation, trip signals and their...

Read More »
Controller has DeviceNet machine control interface option.

Controller has DeviceNet machine control interface option.

Offered with optional DeviceNet machine control interface, MicroLYNX panel mounted assembly employs bipolar stepper motor microstepping drive. Unit measures 2.4 x 3.5 x 2.9 in. and is available with 2 different Drive Output Selections: 12-48 Vdc, 3 A rms - 4 A peak or 24-75 Vdc, 5 A rms - 7 A peak. DeviceNet version is designed to conform with ODVA Volume II, Release 2.0 Errata 3 as Position...

Read More »
I/O Interface offers direct control wiring connections.

I/O Interface offers direct control wiring connections.

Eliminating need for mass termination connectors and ribbon cables, IDC50-TB26 interface fits 4-, 8-, 16-, and 24-position I/O racks by plugging directly into 50-pin ribbon cable connector. Able to accept 24-16 AWG wire sizes, 26-position terminal block provides wiring access to each I/O control line in addition to +V and Common. Applications requiring direct I/O module control include machine...

Read More »
Temperature/Process Control includes assured soak capability.

Temperature/Process Control includes assured soak capability.

Series 16S 1/16 DIN Ramp/Soak Profiler Temperature/Process Control includes variable time base, front panel run/hold key, auto/manual station, and peak and valley indication. High-speed switched Vdc output allows fast SSR loads. Inputs include Type J, K, T, E, L, N, R, S, C, or B Thermocouples; 100 or 1000 Ohm DIN Platinum RTD; 100 Ohm 0.00392 Platinum; 0-10 Vdc; -10 to +10 mVdc; or 4-20 mAdc....

Read More »
Inlet Power Module provides four power entry functions.

Inlet Power Module provides four power entry functions.

General-purpose RP188 universal power line inlet filter and switch eliminate equipment and mains-borne electro-magnetic interference that can cause unstable operation of medical and office equipment. Designed as screw-mounted panel unit with fast-on power connectors on load side, they are approved for input voltages up to 250 Vac and currents up to 10 A. Power entry functions include fully...

Read More »

Drive suits industrial fans and pump applications.

Providing V/f control, 110% overload capability, and various network communication and I/O options, P7 Drive comes factory-programmed and ready to use. It is operated via LCD operator display with 5 lines of 16 characters and includes keypad with copy function for moving chosen parameter sets from one drive to another. Available in ratings from 5-500 hp @ 208/230/240/480 Vac, drive offers open...

Read More »
Pressure Controllers feature infrared port communication.

Pressure Controllers feature infrared port communication.

Series HA430/930 dual-loop controllers include strain gauge type resin pressure input and 24 Vdc transmitter power supply for direct connection to transducers. Available in 1/4 and 1/8 DIN sizes, units offer sampling and control time of 0.025 sec with PID and other parameters settable in 1/100 units. PDA infrared port allows operator to set, change, or monitor settings using Pocket PC. Maximum of...

Read More »
Low-Dropout Regulator has 3.0 A continuous output current.

Low-Dropout Regulator has 3.0 A continuous output current.

With 0.9 V output voltage capability, MIC49300 dual supply LDO responds instantly to abrupt changes in load current. Main supply requires 400 mV headroom to maintain proper regulation, while second supply provides bias voltage to control circuit. Housed in S-Pak 5-lead package, product offers gain bandwidth of up to 10 MHz and supports input voltage as low as 1.4 V. Other features include thermal...

Read More »