Signal Conditioners

Signal Conditioners

Analog Signal Processor upgrades subwoofer plate amplifiers.

Offering programmable platform for subwoofer signal conditioning, SonicMaster1(TM) enables equalization, band-pass filtering, amplifier clipping, and woofer bottoming limiter protection to active subwoofer designs. Subwoofer Module is 3.3 V, 2-chip solution using dynamically programmable ASP with Audio State Machine, allowing designers to develop functions that can be dynamically configured, such...

Read More »
LVDT Signal Conditioner operates from 12 or 24 Vdc.
Signal Conditioners

LVDT Signal Conditioner operates from 12 or 24 Vdc.

Designed for use in PLCs and vehicular testing systems, single channel Model LVC-2500 DC-LVDT Signal Conditioner offers bipolar 0 to ±10 Vdc, unipolar 24 Vdc, or 4-20 mA (sourcing) analog outputs in 3-wire common ground system. Nominal excitation frequencies of 3, 5, or 10 kHz are available at 3 Vrms for operating LVDTs with primary impedance. Front panel span and zero controls permit...

Read More »
Signal Conditioner processes acquired data in real-time.
Signal Conditioners

Signal Conditioner processes acquired data in real-time.

Network-ready, single-box DAPserver 200 conditions, acquires, and logs signals from up to 32 strain gauges. It can sustain throughput of 10 ksamples/sec/channel on all channels, and it samples all channels simultaneously. Unit can output control signals and can be controlled from any PC on network. Featuring 16-gauge stainless steel chassis, system includes handles and mounting hardware for 19...

Read More »
Action Instruments Signal Conditioners Approved for Use in Hazardous Class I Div 2 Areas
Signal Conditioners

Action Instruments Signal Conditioners Approved for Use in Hazardous Class I Div 2 Areas

LEESBURG, VA, USA, 1 August 2006 - Action Instruments, a division of Eurotherm, is pleased to announce the signal conditioners now approved for input/output signals from Div 1 hazardous area locations: o The WV408 - DC voltage/current input isolating signal conditioner and o The WV428 - Thermocouple input isolating signal conditioner. Both models can now be installed directly in the Class I, Div...

Read More »
Signal Conditioner Board offers auto sensor identification.
Signal Conditioners

Signal Conditioner Board offers auto sensor identification.

Embedded, digital Model 4327 CellMite(TM) connects directly to strain gage transducer and simultaneously generates serial output for connection to PC and ±10 V analog output for interface to DAQ systems. It has onboard storage for 3 calibrated sensors, each with integrated 6-point calibration and independent user-specified display setup parameters. Along with automatic TEDS-Tag(TM) sensor...

Read More »
Signal Conditioners uses software to sort and save data.
Signal Conditioners

Signal Conditioners uses software to sort and save data.

CellMite(TM) Digital Signal Conditioners amplify, filter, and linearize output of strain gage sensors. CellView Multi-Display GUI software guides user through sensor calibrations and allows creation of up to 8 independent displays of data, each relating to specific sensor. User selects data source for display, unit of data, whether to record data from that display, and display name. Software...

Read More »
Digital Signal Conditioner provides soil testing.
Signal Conditioners

Digital Signal Conditioner provides soil testing.

Featuring 2 LVDT channels and 2 strain gage channels, CellMite(TM) Quad provides direct digital data input into serial port of standard PC. CellView software allows test to be divided into 8 segments, each of which can be run at different logging rates. Max and min statistics for each logging segment are summarized, comments are shown, and all data is marked indicating which logging segment it is...

Read More »
Signal Conditioners

Signal Conditioners utilize Windows-based control software.

Rack mounted Models 481A and 498A, with 101 Option for computer interface, are supplied with software that presents device settings in spreadsheet table view and is capable of controlling 16 units with 16 channels each, for total of 256 channels. Clicking software's discovery button begins process by interrogating connected units and populating table with each unit's current settings. Software...

Read More »
Signal Conditioner is suited for strain gauge sensors.
Signal Conditioners

Signal Conditioner is suited for strain gauge sensors.

CellMite(TM) Model 4337 Digital Signal Conditioner connects to strain gauge transducer and simultaneously generates serial output for direct connection to PC and scalable ±10 V analog output for interface to DAQ systems. It has storage for 3 calibrated sensors, each with integrated 6-point calibration and independent display setup parameters. Auto-detect feature for TEDS-Tag(TM) capable...

Read More »
Flow Signal Conditioner provides 4-20 mA or 1-5 Vdc output.
Signal Conditioners

Flow Signal Conditioner provides 4-20 mA or 1-5 Vdc output.

Offered with NEMA 4 (IP66) enclosure and CE approval, Model FLSC-45B dc powered frequency-to-analog output signal conditioner accepts low level magnetic pickup signal or high level dc pulse from flow paddlewheel sensor or turbine meter without amplification and converts it into analog output. It features ±0.15% of full scale accuracy, ambient operating temperature of 20-70°C, and...

Read More »

All Topics