Power Distribution Unit features slim 1U design.
Power Distribution Systems

Power Distribution Unit features slim 1U design.

Interpower(TM) 19 in. rack mount unit provides domestic and international single-phase power to equipment racks. Model 852J2L21 offers eight IEC 60320 Sheet F, 15 amp outlets and four Sheet J, 20 amp outlets with C20 inlet. It comes with lighted rocker circuit breaker and is UL recognized, CSA certified, and TUV approved with CE mark. Interpower(TM) IEC 60320 Sheet E Accessory Power Cords and...

Read More »
Power Distribution Unit operates locally or remotely.
Power Distribution Systems

Power Distribution Unit operates locally or remotely.

DC SMARTstart PDU controls and monitors two sets of 6 independent loads. Each output channel is rated to operate at 4 A of dc continuous power and trip at 5.3 A of nominal dc. Remote operation is via RS232 serial console port or LAN TCP/IP telnet connection. PDU monitors line voltage, load current, and internal temperature, and has reverse polarity protection. Programmable power-on and off...

Read More »
Power Distribution Systems

Power Distribution Bus is easy to install at job site.

POWERBUS 225 Low-Amp Busway is designed to specifications, built, and then tested at plant, so end-users avoid complicated conduit bending, working, and then reworking on job site. Rated at 225 or 100 A, it is suitable for use where conduit and cabling are typically installed. Bus makes it easy for user to relocate equipment such as workstations, small machinery, refrigerated display cases, and...

Read More »
Distribution Boxes expedite cable routing.
Power Distribution Systems

Distribution Boxes expedite cable routing.

Plug-In Distribution Boxes are available in 4, 6, or 8 position models, offering common ground as well as negative and positive wires. Multiple inputs or outputs can be realized from one box with one cable. Two versions are available; 4-pin with 1 wire to each connector or 5-pin with 2 wires to each connector, which allows use with N/C and N/O switches. Box construction is heavy-duty plastic with...

Read More »
Power Management Module is suitable for data centers.
Power Distribution Systems

Power Management Module is suitable for data centers.

Power Management Module (PMM) system integrates isolation, conditioning, electronic grade grounding, and power management and distribution for up to 252 output breakers. It monitors main and sub-main breakers as well as all branch circuit breakers. Monitor instantly alerts operators via LCD display and audible alarm before breakers are at risk of tripping. It also handles current distortion...

Read More »
Power Distribution Systems

Power Distribution Systems deliver high current in small size.

Rack-mounted X8340-S08 accommodates up to 8 circuit breakers and protects equipment from short circuits and current overloads. It distributes up to 800 A of DC power in 2U 19 in. chassis. Interruption capacity is 3500 A at 80 Vdc. Model X8340-S08 has four 200 A DC power inputs, each distributing power to two 100 A circuit breakers. Model X8340-S07 provides up to 175A via seven 25 A circuit...

Read More »
Power Distribution Systems

Power System fits telecommunications applications.

X482 telecom power distribution solution fits in 1U chassis, yet distributes up to 900 A. It allows up to 20 circuit breakers to be mounted in 19 or 23 in. racks. Power fed to system input is divided into branch circuits that include protection for individual loads. Circuit breakers have plug-in terminals to permit swapability and front access, and are available in ratings from 100 mA to 50 A at...

Read More »
Power Distribution Unit offers series mode technology.
Power Distribution Systems

Power Distribution Unit offers series mode technology.

Available as 19 in. rack mount or 17 in. modular, PDU features total of 10 outlets, 4 sequentially switched, 4 normally switched, and 2 always on. It includes switch selectable delay, power failure reset latch, remote control capabilities, and daisy chaining. Low voltage shut-down function will automatically shut down in opposite sequence of start-up if voltage drops below 95 V. 15 and 20 A...

Read More »