Generator Coolers feature removable cover plates.

Generator Coolers feature removable cover plates.

Designed with plate fin technology, RCP(TM) Coolers remove heat from electrical generators. Removable, bolt-on cover plate facilitates access for cleaning while keeping cooler installed, without disturbing piping. Leak detector configuration is available to prevent catastrophic failure of motor or generator. Coolers are suited for new and existing power generation installations, from nuclear and...

Read More »

Horizontal Row Cooler suits high density computer systems.

Utilizing waterless pumped refrigerant technology, Liebert XDH is designed for data center applications where there is limited overhead space due to overhead cabling or low ceiling height. Unit fits within row of electronic equipment racks inside hot-aisle-cold-aisle arrangement. Able to cool more than 30 kW per rack, Liebert XDH features flexible piping with quick-connect fittings that allow...

Read More »

Fan Tray features cross-flow cooling technique.

Baffled fan tray utilizes cross-flow cooling fan and features adjustable depth as well as local and remote alarms. Due to its unique configuration, tray requires only 75 cfm. This low-wattage (6 W), 19 in. rack-mount fan tray assembly is CSA-, NEBS-, and UL-compliant. Applications include cooling of rack- and cabinet-mounted electronic equipment in telecommunications, commercial, military, and...

Read More »
Rack Mount Coolers come in 110 cfm and 375 cfm models.

Rack Mount Coolers come in 110 cfm and 375 cfm models.

Utilizing dual radial airflow ball-bearing fan systems, RMF Series is available in 1U and 2U high packages that provide rack heat extraction and system temperature control. Up and Out design draws heated air from rack up into fan system and out back of rack, drawing damaging heat away from sensitive system components. Optional front panel mounted, digital thermometer with remote probe enables...

Read More »
Side-Mount Cooling Units condition electronic enclosures.

Side-Mount Cooling Units condition electronic enclosures.

Offered in NEMA 12, NEMA 3R/4, and stainless steel NEMA 4/4X versions, DTS 3000 Series cools electrical and electronic enclosure applications in various industries. Capacities range from 4,000-20,000 BTU, and operating voltages are 115, 230, and 460 Vac. While stainless steel NEMA 4/4X unit is suited for all wash-down related applications, all units feature unobstructed airflow management for...

Read More »

Sanitary Sample Coolers allow safe taking of samples.

Designed for use in pharmaceutical plants and clean rooms, Sanitary Sample Coolers are constructed of polished 316L SS to take samples from steam or heated water systems for chemistry/TOC, conductivity, and microbiological studies. Available both fixed or portable, cooler includes bracket for wall mounting and can be steam sterilized or de-pyrogenated using a hot air process.

Read More »

Heat Sinks cool condensed electronic packages.

Fabricated from lightweight extruded aluminum, maxiFLOW(TM) heat sinks are utilized for cooling BGAs and hot components inside electronic systems. Featuring low profile spread fin arrays to enable convectional air cooling within restricted/low air flow conditions, they are available in lengths and widths ranging from 10 x 10 mm to 60 x 60 mm, and heights starting at 2 mm.

Read More »

Cooling System employs adaptive condenser system.

Available in 53, 70, 77, and 105 kW downflow units, Liebert DS system controls temperature, air quality, and humidity in areas such as data centers and computer rooms. It uses digital scroll compressors and Liebert Paradenser(TM), which can be installed using traditional refrigerants and transitioned to green refrigerants with no loss in capacity. Also included, iCOM(TM) control system enables...

Read More »