Schneider Electric

Circuit Monitor offers web-enabled forecasting functions.
Communication Systems & Equipment

Circuit Monitor offers web-enabled forecasting functions.

POWERLOGIC-® Series 3000 Circuit Monitor (CM3000) collects and logs energy usage, then analyzes data to forecast trend plots, averages, and demand metering in real time. Processor, open protocol Ethernet communications card, and on-board memory can capture data in standard web browser. Information is served to host circuit monitor, and transparently for other devices connected downstream....

Read More »
Surge Protection Device suits critical power applications.
Electronic Components & Devices

Surge Protection Device suits critical power applications.

SURGELOGIC(TM) LC provides surge suppression and broadband noise filtration. Its series inductors provide surge protection to 40,000 A, while sine wave tracking and filter capabilities provide up to - 75 dB noise filtration. Thermal fuse protects against extreme surge currents and prevents thermal runway conditions. It meets IEC requirements and prevents interruptions in production and data...

Read More »
Nano Drive suits small machine applications.
Controls & Controllers

Nano Drive suits small machine applications.

ALTIVAR-® 11 AC drive is designed for -¼ to 3 hp motors, making it replacement for electromechanical controls in 2-speed motor or DC applications. Available in 115 and 230 V single phase and 230 V 3-phase, drive includes built-in drive motor thermal protection. It features 2- or 3-wire control and has 4 logic inputs, 1 fault relay, and 1 digital output. Switching frequency is adjustable from 2...

Read More »
Surge Protector mounts on DIN rail.

Surge Protector mounts on DIN rail.

MERLIN GERIN-® Multi 9 SPD protects terminal connected devices against transient voltages up to 80,000 A. Plug-in module enables module replacement without unwiring electrical connections. Thermal fuse protects against extreme surge currents and prevents dangerous thermal runway conditions. Surge protectors are available in one-, two- and four-pole models, and most international voltages for...

Read More »
Circuit Breakers have built-in open communication platform.

Circuit Breakers have built-in open communication platform.

POWERPACT-® P and POWERPACT-® R circuit breakers are available with I-LINE-® panelboards and POWER-STYLE-® QED-S and QED-2 switchboards. P-frame circuit breakers measure 9 in. wide, while R-frames measure 15 in. wide. Both breaker styles are available with 80% or 100% rating (up to 1,200 A for P-frame and 2,500 A for R-frame). Built-in MODBUS-® protocol provides open communications platform.

Read More »
Soft Starter protects motor and machine.

Soft Starter protects motor and machine.

ALTISTART-® 48 line works with asynchronous motors with ratings from 208 to 690 Vac. Torque control during acceleration and deceleration limits stress on drive chain and reduces hydraulic transients. Starter monitors for overloads and underloads, and limits current and voltage drops when starting. It has Modbus and Ethernet TCP/IP, with FIPIO, Profibus DP, and DeviceNet available as options....

Read More »
Architectural & Civil Engineering Products

Power Distribution Bus is easy to install at job site.

POWERBUS 225 Low-Amp Busway is designed to specifications, built, and then tested at plant, so end-users avoid complicated conduit bending, working, and then reworking on job site. Rated at 225 or 100 A, it is suitable for use where conduit and cabling are typically installed. Bus makes it easy for user to relocate equipment such as workstations, small machinery, refrigerated display cases, and...

Read More »
Power Meter checks tenant energy consumption.
Test & Measurement

Power Meter checks tenant energy consumption.

POWERLOGIC(R) 480V monitors 240 to 480 V applications and allows commercial contractors and building managers to decide how to charge tenants based on real-time energy consumption. It is suitable for commercial and industrial submetering projects, including residential and commercial multi-tenant facilities. Palm OS interface and kYZ pulse output contact provide control systems and building...

Read More »
Power Correction System uses active harmonic filtering.
Communication Systems & Equipment

Power Correction System uses active harmonic filtering.

MCC-mounted ACCUSINE(R) Power Correction System (PCS), with expandable, scalable filter, quickly reacts to harmonic waveforms to produce harmonic cancellation waveforms. System decreases harmonic-related overheating of cables, switchgears, and transformers. Response to load fluctuations begins in 40 microseconds, with 8 milliseconds for full response to step load changes. Device filters to 50th...

Read More »
Circuit Monitor provides power system surveys.
Communication Systems & Equipment

Circuit Monitor provides power system surveys.

POWERLOGIC Series 4000 has sealed case design, allowing it to be transported to various locations within facility. Portable unit is suitable for temporary monitoring, or where existing switchgear will not accommodate permanent installation of circuit monitors. Base unit includes detachable display and necessary cables. Upgrade option adds high-speed transient-detection. Optional Ethernet...

Read More »

All Topics