Transmitter comes in integral and remote configurations.

Transmitter comes in integral and remote configurations.

U Series Non-Contact Ultrasonic Transmitter provides accurate level measurement in applications such as sump pit monitoring, gypsum silo level, fly ash silos, and steam, and condensation. It offers automatic gain and low frequency sensors, which penetrate dust, fog, and foam. Its programming allows transmitter to adapt to real-time conditions.

Read More »
Level Probe works with radar transmitter.

Level Probe works with radar transmitter.

Sanitary, 3A Authorized Single Rod Probe for Eclipse(R) Guided Wave Radar transmitters is made of 316 stainless steel with 20 RA surface finish. Probes are available in lengths up to 20 ft, in 2, 3, or 4 in. sizes, with Tri-Clover style 16 AMP sanitary fitting. Applications include food, pharmaceutical, and bio-tech industries.

Read More »
Density Transmitter checks liquid concentration.

Density Transmitter checks liquid concentration.

DT301 Touche transmitter performs continuous, on-line measurements. Capacitive, differential-pressure transmitter is coupled to pair of pressure repeaters immersed at different levels in process. Integral temperature sensor compensates for temperature variations. Software calculates fluid density. DT301 provides accuracy of +/-0.0004 g/cm3, with range of 0-0.5 to 0-5 g/cc. Models are available...

Read More »
Two-Wire Transmitters mount on DIN rail.

Two-Wire Transmitters mount on DIN rail.

200-Series 2-wire transmitters have 1 3/4 in. dia housing that fits most standard thermocouple heads, or may be surface mounted using two screws. Thermocouple, RTD, potentiometer and millivolt versions are available, including field-rangeable thermocouple and RTD models. It has low-drift circuitry, in-terminal cold junction compensation, Quick Check output LED, and -40 to +80 deg C ambient...

Read More »
Non-Isolating Transmitters are loop powered.

Non-Isolating Transmitters are loop powered.

LPN-P 3-wire potentiometer provides LED indication of loop current, reverse polarity protection, and corrosion proofed circuit boards and components. LPN-R linearized 3-wire RTD transmitter features Pt100 RTD standard input and 40-200mV output test signal. LPN-R-H linearized in-head, 3-wire transmitter fits RTD connection heads. Compact DIN rail mount enclosure facilitates installation.

Read More »

Pressure Transmitter works in hazardous environments.

NEMA 4 rated PT-420 GP has solid state transducer element, 4-20 mA output, and accuracy to +/-0.25%. Transmitter is available in intrinsically safe and flame proof models to meet Class I, Div. 1, Groups B, C, D; Class II, Groups E, F, G; and Class III, Type 4X environments. It is digitally temperature compensated for accuracy and long-term stability. Applications include hydraulics, pneumatics,...

Read More »
Pressure Transmitters offer 0.1% accuracy.

Pressure Transmitters offer 0.1% accuracy.

Based on silicon piezoresistive sensors, DTE1000 digital transmitters have welded stainless-steel construction for media compatibility. Pressure read-out and all control functions are accessible via RS485 interface. Programmable transmitters can measure pressure on request or continuously, and store values taken at preset intervals in internal memory for later retrieval. Pressure ranges are from...

Read More »

Transmission System transmits 4 independent audio channels.

Pure Digital FiberlinkÂ-® 4040 Series fiber optic transmission system offers all digital transmission of 4 audio channels over single-mode or multi-mode fiber. Channels may be used to transmit 2 sets of stereo signals, or to support 4-channel surround sound. Audio channels may be configured for either balanced or unbalanced input and output, with or without input termination. System operates...

Read More »
Pressure Transmitter measures vacuum.

Pressure Transmitter measures vacuum.

NIST-traceable Model FPV provides vacuum pressure measurements from 10 in. water to 15 psiv. Selectable parameters include choice of 0.1% or 0.25% accuracy, 6 electrical terminations, 6 pressure ports, and 0-5 Vdc, 0-10 Vdc, 2-wire 4-20 mA, or mV/V output. Long-term stability is 0.04% FS for 30 months. Certifications are available for CE and for intrinsically-safe installations.

Read More »

All Topics