AMETEK Mocon

Oxygen Transmission Rate Tester is optimized for sensitivity.
Laboratory and Research Supplies and Equipment

Oxygen Transmission Rate Tester is optimized for sensitivity.

Able to measure barriers to 5x10-4 cc/(m-² x day) for oxygen permeation testing of films or packages at precise temperature and RH conditions, OX-TRAN-® Model 2/21 10x module complies with ASTM D3985 and employs COULOX-® coulometric sensor. Electronics reduce system noise, while TruSeal™ film cell design eliminates edge-leakage and ensures perfect seal every time. Each module contains- 2...

Read More »
Food Safety System offers rapid indicator organism testing.
Test & Measurement

Food Safety System offers rapid indicator organism testing.

In addition to total count testing capability, GreenLight-® Microbial Detection Platform can simultaneously test for enterobacteriaceae and total coliform counts using oxygen depletion sensor and automated reader. System is configured to allow quantitative data and pass/fail testing in fully automated mode, enabling extensive quantitative test results in 10 hours or less, vs 24 hours required by...

Read More »
WVTR Instrument measures ultra-high barrier films.
Sensors, Monitors & Transducers

WVTR Instrument measures ultra-high barrier films.

Using proprietary technology to measure- water vapor transmission rate- down to 5x10-5 g/(m-²-day), AQUATRAN-® Model 2 targets ultra-high barrier structures such as flexible films for OLEDs. Instrument utilizes AquaTrace-® Gold coulometric sensor which is based on Faraday’s Law. Every water molecule entering sensor is directly converted to measureable charge. No calibration is necessary,...

Read More »
Conditioning System accelerates oxygen permeation testing.
Electronic Components & Devices

Conditioning System accelerates oxygen permeation testing.

Developed for use with OX-TRAN-® Model 2/61 Oxygen Permeation Test System, RACK-6™ offers separate 6-cell conditioning unit which enables flexible or rigid packages to be brought to equilibrium offline before moving them to OX-TRAN Model 2/61 for final test results. Container Transfer Units allow individual package transfer from conditioning unit to testing unit. Supplied with 12 CTUs, RACK-6...

Read More »
Oxygen Test System gains functionality via 3 accessories.
Laboratory and Research Supplies and Equipment

Oxygen Test System gains functionality via 3 accessories.

Serving food and pharmaceutical applications, OpTech-® system uses optical sensor that gives off light directly related to amount of oxygen present in package headspace or dissolved oxygen in liquid product. Available accessories include portability kit to enable mobile testing away from lab; needle attachment, with fluorescing sensor material applied to its tip, for testing packages...

Read More »
Dairy/Milk Testing Instruments measure bacterial levels.
Agricultural & Farming Products

Dairy/Milk Testing Instruments measure bacterial levels.

GreenLight-® instruments use oxygen-depleting technology to measure aerobic bacterial levels and can provide results for raw milk within 30 min to 5 hr. When fully automated GreenLight 930 is used, bar-coded APCheck(TM) vials (which has built-in sensor material) can be batch loaded onto 48-position carousel or individually loaded at any time during continuous mode. GreenLight 910 is sized to...

Read More »
All-in-One Tester analyzes packages with degassing valves.
Laboratory and Research Supplies and Equipment

All-in-One Tester analyzes packages with degassing valves.

As combination testing system for packages with one-way degassing valves, MultiCheck-® 425 measures headspace carbon dioxide (CO2) and oxygen (O2). System also performs pressure decay leak test, seal strength burst test, and one-way degassing valve performance test via Valve Test Unit(TM) (VTU). By combining 5 tests in one unit, product conserves time, labor, and samples needed to conduct...

Read More »
Non-Invasive Analyzer examines O2 in pharmaceutical blisters.
Laboratory and Research Supplies and Equipment

Non-Invasive Analyzer examines O2 in pharmaceutical blisters.

With optical sensor that gives off light directly related to amount of oxygen present, OpTech-® - O2 system enables non-invasive, non-destructive thermoformed blister package testing. System complies with ASTM F2714, is stable in ambient light, and can determine oxygen headspace, dissolved oxygen, ingress, and permeation rate in flexible and rigid packaging under real-life conditions. Values are...

Read More »
Fully Automated Tester measures bacterial aerobic plate count.
Test & Measurement

Fully Automated Tester measures bacterial aerobic plate count.

Targeting companies and laboratories dealing with food, GreenLight(TM) 930 provides aerobic plate count (APC) or total viable count (TVC) of food sample's microbial load using sensing assay or vial. Results, depending on bacterial load, can be obtained between minutes and 8 hr, and process is automated via 48-position carousel inserted into main unit. System feeds bacterial information to PC via...

Read More »
Package Integrity Tester addresses degassing valve issues.
Test & Measurement

Package Integrity Tester addresses degassing valve issues.

MultiCheck(TM) 400 combines O2 headspace, pressure decay leak, seal strength burst, and valve (leak and seal strength) tests, decreasing time, labor, and samples required to conduct individual assessment of packages with one-way degassing valves. Single package cycles through all of analyses on one unit, and included Valve Test Unit(TM) (VTU) measures values to tenths of pound/in.-² System is...

Read More »

All Topics