Quantcast
 
Search for: Search what?
Nov 26, 2009  
 Sections
Latest New Product News
Industry Market Trends
Green & Clean News
Association & Government News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP

Advertisement
Welding Equipment & Supplies -> Welding Supplies & Accessories -> Shutoff Valves


Shutoff Valves


   Add to Google      PDF icon

(Showing headlines 21 - 31)   1 2
Valve performs three functions.

Valve performs three functions.

Bell & Gossett
Morton Grove, IL 60053
Sep 03, 2003 Triple Duty® Valve consists of calibrated balance valve, which provides precise flow with 8–9 turns; non-slam check valve, which assures positive shut-off without water hammer or valve chatter; and shut-off valve which includes memory button that allows entire valve to be returned to initial balanced position after shut-off. Triple Duty® Valve comes in straight pattern flange design, and resists harsh operating pressures, high temperatures, and aggressive liquids.

Butterfly Valve resists vibration.

Butterfly Valve resists vibration.

Dwyer Instruments, Inc.
Michigan City, IN 46361 0373
Dec 11, 2002 Series SAE hydraulic reservoir shut-off valve, for fluid-power industry, includes O-ring flange face seal that eliminates hydraulic fluid connection leaks. Design provides bubble-tight reservoir shut-off up to 25 psi and max temperature of 180°F. Optional Viton® O-ring seal provides max temperature up to 300°F. Flange sizes include 2, 2½, 3, 4, and 5 in. Open/close detent position lock can be infinitely positioned to achieve desired flow rate.

Butterfly Valves resist vibration.

Butterfly Valves resist vibration.

Dwyer Instruments, Inc.
Michigan City, IN 46361 0373
Dec 09, 2002 Series SAE hydraulic reservoir shut off valves offer O-ring flange face seals that comply with S.A.E. J518 dimensional requirements. Products provide bubble tight reservoir shut off up to 25 psi and maximum temperature of 180°F (up to 300°F with optional Viton® O-ring seal). Flange sizes include 2, 2½, 3, 4, and 5 in. models. Suited for fluid power industry, units allow for adjustment by incorporating open/close detent position locks.

Control Valve permits shutoff up to 750 psi.

Control Valve permits shutoff up to 750 psi.

Leslie Controls, Inc.
Tampa, FL 33637
Dec 06, 2002 DigiValve Series consists of electric actuator mounted on high-capacity control valve. High-thrust, stall-proof motor provides positive positioning and prevents burnout. Digital Actuator Control allows automatic adaptation to valve stroke, characteristic adaptation and manual operation with input keys. DigiValve Series operates with analog signals 4-20 mA, 0–10 Vdc or Profibus DP. Manual handwheel is standard.

Shutoff Valve closes as temperature rises.

Shutoff Valve closes as temperature rises.

Waters Equipment Co.
Lansdale, PA 19446 0576
Jun 11, 2002 Hi-Temp Shut-Off Valve for sampling systems responds automatically to temperature, requiring no reset or operator involvement. If temperature reaches 120°F, valve begins to close inlet orifice, and at 130°F, inlet orifice fully closes. Ram-type plug provides tight seal upon shutoff, and valve automatically opens when temperature cools. Valve is made of stainless steel and Teflon and is rated for 3000 psi.

Ball Valve provides easy access.

Ball Valve provides easy access.

Parker Hannifin Corp., Brass Products Div.
Otsego, MI 49078 1472
Apr 30, 2002 Three-Piece Swing-Out Ball Valve provides direct access to internal seals without disturbing pipe alignment. Seal replacement is performed by removing one body bolt, loosening other three, and swinging out center section. Valve body is made from CF-8M stainless steel and is available in female pipe sizes from 1/4 through 2 in. Working pressure is 1000 psi and temperature range is 0 to 400 deg F.

Mini Ball Valves for use in confined spaces.

Mini Ball Valves for use in confined spaces.

Parker Hannifin Corp., Brass Products Div.
Otsego, MI 49078 1472
Apr 26, 2002 Brass mini ball valves are rated at 300 psi and have working temperature range of 0 to 250 deg F. Extruded brass body is nickel plated with 1/4 turn handle for positive full shutoff. Valves have blowout proof stem, hard chrome plate ball, and Teflon seats. They are available in 1/4, 3/8, and 1/2 in. female/female sizes.

Gas Shutoff Valves incorporate single aluminum bodies.

Gas Shutoff Valves incorporate single aluminum bodies.

ASCO (Automatic Switch Co., Valve Div.)
Florham Park, NJ 07932
Apr 22, 2002 H113 Series double block gas shutoff valve contains 2 distinct shutoff valves and one watertight Hydramotor(R) actuator. Optional Posi-Prove system tests valve seal tightness, and conducts self-check automatically upon system startup. Two independent operating shafts accomplish valve closure, while inlet screen prevents debris from obstructing valve closure. Pipe sizes range from 3/4 to 3 in. Maximum operating pressure differential is rated to 25 psi.

Control Valves suit light industrial applications.

Control Valves suit light industrial applications.

Leslie Controls, Inc.
Tampa, FL 33637
Feb 20, 2002 DKLO Series Control Valves offer Class IV shutoff up to 400 psig, and stainless steel trim. Single seat bronze model has union end connections and is available in 1/2 through 2 in. sizes. Single seat cast iron model with flanged connections is available in 2 1/2 through 4 in. sizes. Epoxy coated pneumatic actuator has multi-spring design. Live loaded V-ring packing assembly is self-adjusting, minimizing maintenance.

Ball Valves and Actuators suit severe duty applications.

Ball Valves and Actuators suit severe duty applications.

High Pressure Equipment Co.
Erie, PA 16505 3522
Feb 05, 2002 Trunion style ball valves and actuators are specifically designed for shut-off of liquid and gas flow up to 20,000 psi. Two 3-way and 3-way diverter ball valve configurations are available in orifices of .187 or .375 in. Valves incorporate 316 stainless steel construction, Viton 0-rings, Arlon ball seats and peek bearing washers. They have 1 1/16 in. dia hole for panel mounting. Air-operated actuators accommodate remote operation.

High-Pressure Valves provide positive leak-free shut-off.

High-Pressure Valves provide positive leak-free shut-off.

Springer co-ax Inc.
Penndel, PA 19047
Jan 30, 2002 Co-ax(R) valves are available for pressures up to 7,500 psi, actuation speeds of 30 msec, and in wide range of sizes, seal and construction materials. They handle high pressure applications, such as gas turbine fuel systems, cylinder filling, cryogenic pumps and vacuum furnace quench gas supply systems. Units come in 2/3- and 3/2-way versions, and in normally-opened or normally-closed configurations. Standard orifice sizes range from 2 to 15 mm.




(Showing headlines 21 - 31)   1 2


Category Advertisements
ThomasNet News Advertisers



APS' Pre-Mixed & Frozen Syringes or Cartridges eliminate the need to weigh and mix reactive resin optic materials






Home  |  My ThomasNet News  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2009 Thomas Publishing Company
Terms of Use - Privacy Policy