Fluid & Gas Flow Equipment
(Showing headlines 3601 - 3620) << 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 ...
|
 Side Access Filter Housing offers leak-free performance.Camfil Farr
Riverdale, NJ 07457
Nov 03, 2003 With compact design, 5P Glide/Pack® air filtration housing accommodates 2 in. HVAC grade prefilter and 4 or 6 in. deep HVAC grade final filter. Fin seal on filter track limits leakage of unfiltered air across filter assembly to less than ½ of 1% at rated airflow. Neoprene door gasket and UV-resistant, star-style door handles ensure housing-to-filter seal. Unit's 16-gauge galvanized steel construction has dual-access, swing-open doors. |
 Flow Control Valves offer dual metering capability.Lee Company, The
Westbrook, CT 06498 0424
Nov 03, 2003 Dual Metering Flow Control Valves are available in .187 and .281 in. diameter models with nominal weight of 1.5 and 5 g, respectively. Different metered flow rates for forward and reverse flow directions, within specific range, can be specified. All metal components are stainless steel. |
 Isolation Valves integrate with manifold assemblies.KIP Incorporated
Farmington, CT 06032 3140
Oct 31, 2003 Available in 2-way NC configuration, isolation valves employ elastomer diaphragms and are suited for control of corrosive and aggressive media. Able to be equipped with low-wattage (0.65 W min) coils, 2 valves may be combined on common base for 3-way operation. Custom manifold assemblies include fittings, tubing, and other accessories. Valves may be combined on manifold block to simplify pneumatic or liquid circuit. |
 Port Connectors suit 37° male end fittings.Adaconn & Inserta Products, Inc.
Blue Bell, PA 19422
Oct 31, 2003 ADACONNâ„¢ Port Connectors, when used with ADAFLANGEâ„¢ adapters and/or ADAFLANGEPORTâ„¢ adapters, give flexibility in plumbing compact SAE Four Bolt Flange connected systems without welding. Fluid is confined to inner bore where supporting wall thickness is greatest. Connectors are proof tested with Code 62 ADAFLANGEâ„¢ and ADAFLANGEPORTâ„¢ adapters to proof pressure of 18,000 psi and are offered in sizes up to 3½ in. |
 Diaphragm Pump is constructed of stainless steel.ARO - Ingersoll-Rand Fluid Products
Bryan, OH 43506
Oct 27, 2003
Air-operated EXP delivers up to 123 gpm and has 1½ in. fluid ports. Unbalanced major shift valve provides stall-free operation, and air-motor design features corrosion-resistant housing with anti-ice and trip-rod valve designs to avoid pump stall-out while insuring positive shift. Suited for use in corrosive applications and environments, pump incorporates stainless steel wetted materials and corrosion-resistant polypropylene air section.
|
 Dry Vacuum Pump System works with rotary evaporators.Gardner Denver Welch Vacuum Technology, Inc
Skokie, IL 60077
Oct 27, 2003 Self-Cleaning Dry Vacuum Systemâ„¢ features diaphragm pump that resists chemical vapors by using fluorinated plastics on all wetted surfaces. Pump operates without oil, delivering vacuum to 12 mbar with free air displacement of 1.2 cfm. Self-cleaning purge automatically runs for 2 min at shutdown to rid pump of residue. Adjustable bleed valve allows regulation of vacuum level. Glass inlet separator helps prevent pump from ingesting liquids or particulates. |
 Air Filtration Systems remove dust particulate and fumes.Henkel Loctite Corporation
Rocky Hill, CT 06067
Oct 27, 2003
Benchtop systems, available with/without 2 x 24 in. flexible arm, operate as open plenum for working area to 12 in. wide. Units feature bi-colored LED light and deep bed activated carbon fume filter. Freestanding systems are offered in 115 V, 60 Hz; 230 V, 50 Hz; and explosion-proof models. They offer 14 x 18 in. filter, differential pressure gauge, multi-stage filtration, and deep bed, 20 lb activated carbon fume filter.
|
 Diaphragm Pump is suited for process industries.Ingersoll-Rand Productivity Solutions
Annandale, NJ 08801
Oct 22, 2003 With 1½ in. fluid ports, non-metallic, air-operated EXP incorporates stall-free valve design. Main air motor features corrosion-resistant construction with anti-ice valve configuration and trip-rod design to ensure positive shift. Body has natural PVDF/Polypropylene wetted parts for chemical/fluid compatibility. Capable of flows to 170 gpm, it includes 4-piece major air valve block and side-mounted inlet/discharge. |
 Check Valve is not dependent on gravity for sealing.Plast-O-Matic Valves Inc.
Cedar Grove, NJ 07009
Oct 22, 2003 Able to maintain bubble-tight seal when mounted in any position, valve diaphragm automatically positions itself against valve seat in identical location each time. With no internal sliding or loose parts to slam or vibrate, chattering is eliminated, and operation is silent. Available in ½, ¾, and 1 in. NPT sizes, body materials are PVC, Polypropylene, PVDF, and Teflon®. Diaphragms are Buna-N, EPDM, or Viton®. |
Fusible Link Assemblies offer 3 different torque ratings.Marwin Ball Valves, Div. Of Richards Industries, Inc.
Cincinnati, OH 45209
Oct 20, 2003 Fusible Link Assemblies, for Series 3000 Valves, utilize cam placed on top of spring pack rather than fixed loaded arm. Low Torque Series, ranging from 0–150 lb-in., uses valve handle to arm fusible link assembly. Mid Torque Series, ranging from 160–830 lb-in., uses detachable arming handle to arm link assembly, and High Torque Series, ranging from 835–21,000 lb-in., uses declutchable manual override gear operator to arm assembly. |
 Integrated Pump/Valve offers alternative to syringes.Upchurch Scientific, Inc.
Oak Harbor, WA 98277
Oct 17, 2003 Confluent IPV Integrated Pump and Valve, available to laboratory and diagnostic equipment OEMs, provides direct plug-in replacement for use on Cavroâ„¢ XP-3000 drivers. It delivers comparable precision and accuracy to glass barrel/Teflon® syringes. |
 Centrifugal Pumps provide corrosion-resistant design.Wanner Engineering, Inc.
Minneapolis, MN 55403
Oct 17, 2003 Stan-Cor Teflon® Series non-metallic, ANSI Pumps feature solid Teflon® pump head for chemical compatibility and corrosion/abrasion resistance with fluid temperatures up to 325°F. They provide total dynamic head to 90 ft and flow rates to 500 gpm. Heavy-duty drive shaft and duplex contact thrust bearings ensure low maintenance. Pumps are suited for dirty, abrasive, corrosive, and reclaim process fluids in harsh, industrial applications. |
 Low-Emission Tube reduces vapor permeation.Norma Products, Inc.
Wixom, MI 48393
Oct 16, 2003 Able to reduce permeation in automotive vapor lines by up to 80%, NORMAFLEX® LET 10 features 3-layer, polyester-based design. All materials are flourine-free. Product is thermoformed to customer's desired length and diameter. NORMAQUICK® 2K (2-shot) spigot can be incorporated into assembly instead of HDPE spigot when low permeation is important. Corrugated tubing is available for applications requiring routing flexibility. |
 Fill Manifolds provide safe cylinder filling.Acme Cryogenics, Inc.
Allentown, PA 18103
Oct 15, 2003 EZ Block Carbon Dioxide and Nitrous Oxide Fill Manifolds, made of one-piece machined brass barstock, offer alternative to traditional pipe header configurations. Modular design facilitates set-up, reconfiguration, and expansion for changing needs. EZ Blocks can be connected together using flexhose or pipe nipple. Accessories include wall mount bracket and floor stand. |
Poppet Valves offer flow rates up to 40 Cv.Norgren
Littleton, CO 80120
Oct 15, 2003 Prospector® Poppet Valves, available in solenoid and pilot actuated formats, feature operating pressure to 290 psi with pilot air supply pressure ranging from 14–290 psi bar. Operating temperature is -84 to +129°F for solenoid pilot version and -84 to +174°F for air pilot version. Manufactured from die cast aluminum, 2/2 and 3/2 inline valves are suited for filtered and lubricated compressed air environments. |
 Flow Conditioner guards analyzers from liquid damage.Welker Engineering Co.
Sugarland, TX 77478
Oct 14, 2003 Able to remove liquids and particulates during gas sampling operations, stainless steel Guardian combines Automatic Liquid Shut-Off and Liquid Eliminator. Gas sample enters concavity where free liquids and aerosols are flushed through bottom and drained off, while conditioned gas flows through membrane separator to analyzer. Compact unit measures 2¼ x 4½ in., and installs into chromatograph, calorimeter, moisture analyzer and stack sampling systems. |
 Positive Displacement Pumps feature oil level monitor.Wanner Engineering, Inc.
Minneapolis, MN 55403
Oct 13, 2003 Hydra-Cell Series D35 Pumps use monitor to detect oil level changes, minimizing process interruptions and potential damage. Five Hydra-Cells in pentaplex design allow pumps to provide steady, pulse-free flow. Seal-less, self-priming units include Timken® roller bearings and can run dry without damage. They are suited for remote or critical pumping applications, such as automotive plants, oil refineries, chemical processing plants, and paper mills. |
 Pressure Relief Valves handle air, gas, steam, and liquid.Spirax Sarco, Inc.
Blythewood, SC 29016
Oct 10, 2003 Series 211 and 632 Safety Valves provide over-pressure protection in air or gas compressors, pressure vessels, piping, boilers, and cleaners. Disc, seat, and stainless steel spring provide bubble-tight seal. Certified for ASME Section I or Section VIII Code applications, valves serve operating pressure from 5–250 psi, with 250 psig max set pressure at 406°F. Relief performance is 39-7,810 scfm for air, gas, or vapor; 111-22,148 lb/hr for steam; and 9-478 gpm for liquid. |
 Tri-Wing Pump handles low-viscosity fluids.Viking Pump Inc., A Unit Of IDEX Corp.
Cedar Falls, IA 50613 0008
Oct 10, 2003 AccuLobeâ„¢ pump utilizes tri-wing rotor, constructed of nickel-based non-galling alloy, to provide sealing surfaces and clearances that minimize slip on water-like fluids. Casing design incorporates 4 beveled cusps that allow pump to self-drain. With capacities to 9.2 gpm and pressures to 175 psi, pump conforms to 3-A standards and is EHEDG certified for CIP applications. It offers foot or bulkhead mounting or close coupling to NEMA C-face or IEC flange motors. |
 Ring Seal Assemblies handle temperatures up to 608°F.Parker Hannifin Corp., Seal Group
Irvine, CA 92612 1073
Oct 10, 2003 KF-Type assemblies are available in NW flange sizes from ½â€“12 in. Offered in 7 elastomer seal materials, products consist of aluminum or stainless steel centering ring with integral elastomer o-ring seal. O-ring provides conformability for static sealing, while centering ring holds seal in correct position against mating flanges. Products exhibit resistance to compression set and temperatures to 608°F, depending on material. |
(Showing headlines 3601 - 3620) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231
|
|
|