Steam Traps

Hot Trap extends pump maintenance intervals.
Steam Traps

Hot Trap extends pump maintenance intervals.

Designed to thermally decompose liquid diethyl zinc used in depositing some transparent conductive oxide films in thin film solar manufacturing, Hot Trap extends pump maintenance intervals from 1 week up to 6 months. Gases leaving process chamber pass through hot trap before entering vacuum pump. Heated to temperature that optimizes DEZ decomposition, trap's cartridges only require replacement on...

Read More »
Steam Traps

In-Line Condensate Trap prevents odors and insects.

Designed to optimize efficiency of all gravity-drained minisplit air conditioners, Model EZT-180 features rubber check valve that prevents unconditioned and unfiltered outdoor air infiltration into minisplit airstream. Straight transparent trap, measuring 2.75 in. long and 5/8 in. in diameter, is waterless and freeze-resistant. Unit comes with 9/16 in. diameter adapter, which enables it to fit...

Read More »
Steam Traps

Ball Float Steam Trap withstands high-pressure applications.

Series FTC80-FB serves process applications in chemical, hydrocarbon processing, and pulp and paper industries, where pressures can reach 1,160 psig. Body and cover are made of cast steel with all socket weld connections, and self modulation provides soft and continuous discharge. Main valve assembly has tight shut-off under no-load conditions, and all internals are stainless steel and have...

Read More »
Steam Traps

Float and Thermostatic Steam Traps are constructed of stainless steel.

Model FTS-150 steam trap has 0-150 psig operating range while FTS-300 operates from 0-300 psig. Manufactured with all stainless steel, units are available in Â-½ in. NPT pipe connections. They feature single-seated mechanism that offers 100% turn down ratio on pressure and flow, as well as tight shut-off on no load, allowing instantaneous response to condensate load changes. Rust- and...

Read More »
Steam Traps

Thermodynamic Steam Trap includes replaceable seat.

Engineered for pressure rating up to 3,190 psig, Model TD120M is suited for draining saturated and superheated steam mains in O.P.C. and power generation industries. Unit features distinct on-off cycle that facilitates testing, integral sintered stainless steel strainer, and replaceable hardened seat and disc, which enables in-line servicing. Available in Â-½, ¾, and 1 in. sizes,...

Read More »
Condensate Traps feature cleanable, transparent design.
Steam Traps

Condensate Traps feature cleanable, transparent design.

Suited for residential, commercial, and mini-split air conditioning equipment, EZ Traps® prevent introduction of unconditioned ambient air into airstream, and prevent energy loss due to conditioned air being expelled through drain line on positive pressure systems. Compliant with International Mechanical Code, waterless traps automatically drain bacteria-generating standing water and eliminate...

Read More »
Steam Traps

Hopper Bottom Hydraulic Trap Opener Kits

Hydraulically Powered Traps save time, reduce workplace injuries and they can even be remotely operated, reducing the need for extra personnel. These kits are easy to install & provide immediate Cost Savings. In today's market-place time is money, and improving the efficiency of redundant operations can have big effects to your customer's bottom line. The implementation of hopper bottom hydraulic...

Read More »
Steam Traps

Steam Trap Valve Station is available in left-handed version.

Big-Block Universal Mount Valve Station allows flexibility in installation and maintenance with access for testing and blowdown. It includes 2 isolation valves; integral strainer, blowdown valve, and test port; 304L SS body; adjustable grafoil packing; and universal, 2-bolt swivel trap mount that installs permanently and accommodates thermostatic, inverted bucket, and thermodynamic style traps....

Read More »
Steam Trap has thermodynamic design.
Steam Traps

Steam Trap has thermodynamic design.

Offered in 4 sizes that can be mounted in any position, W.E. Anderson® TDST Series controls steam and condensate movement to optimize removal of latent heat from steam for efficient system operation. Cyclic on-off operation is made possible by disk that pushes open from incoming condensate and closes tightly when steam tries to escape. When trap is mounted vertically, it self-drains for...

Read More »
Steam Traps

Thermostatic Traps suit receiver and air line drainage.

Featuring cast iron body, all stainless steel corrosion-resistant internal components, NPT pipe connections that are directly inline with no change in elevation, and plugged bottom drain, 1Â-½ in. NPT FAI-30 and FAI-200 are straight through, in-line float drainers with single seats and lever operation. Offered at 2 flow ratings, FAI-30 can handle up to 11,549 lb/hr at 30 psi and 450°F,...

Read More »
How SpinSelect Can Save You Time and Money
Sponsored

How SpinSelect Can Save You Time and Money

Thanks to the unique SpinSelect™ Multi-Pocket selectable quick change tool holder, it's time to rethink the range, complexity and volume of parts that your lathe can produce. Our Spin-Select™ tool was created to increase productivity and consistency by decreasing downtime associated with lathe cutting tool and insert setups or changeovers. This product is a game-changer for the industry and we're pleased to show you why.