Company News

Bridgeport Fittings, Inc.

705 Lordship Blvd., Stratford, CT, 06615, USA

  • 203-377-5944

Latest New Product News from
Bridgeport Fittings, Inc.

Electrical Equipment & Systems

Conduit Bodies are UL compliant.

Dec 05, 2008

Manufactured with die cast copper free aluminum with gray enamel finish, Combination Type LLR conduit bodies are UL Listed rain tight when used with threaded Rigid/IMC conduit and Rain tight EMT connectors. Units come preassembled with cover and gasket, and are available in ½-2 in. trade sizes. Read More

Electrical Equipment & Systems

Cable Connectors feature Whipper-Snap® or E-Z Lock® design.

Aug 27, 2008

Designed for use with aluminum interlocking armored all purpose MC Cable, MCI-A line of cable connectors includes Whipper-Snap single-screw, strap-type connectors to connect 14/2 to 10/4 MCI-A cable to box or enclosure. It also includes Whipper-Snap 2-screw, strap-type connectors for use with 14/2 to 10/3 MCI-A cable, Whipper-Snap snap-in, U-shaped strap connectors for use with MCI-A cable 14/2... Read More

Electrical Equipment & Systems

Conduit Couplings feature watertight design.

Aug 11, 2008

Available in ½-4 in. sizes, Raintight 3-piece, self-aligning conduit couplings join 2 lengths of threaded rigid or IMC conduit. Units feature malleable iron construction and zinc electroplating, with mating components to which threaded conduits are securely joined in telescoping fashion. Oversized O-ring prevents water entry and self-aligning feature on UL-listed couplings allows smooth wire... Read More

Electrical Equipment & Systems

Connector secures square locked flexible metal conduit.

Jun 10, 2008

UL recognized for use within listed assemblies, USL-120 is provided with set screw that secures conduit without damaging conductors. Flexible Steel Conduit Connector can be used with assemblies including office partitions, showcases, merchandising displays, lighting fixtures, range tops, and other appliances. Read More

Electrical Equipment & Systems, Mechanical Power Transmission

Combination Coupling allows joining of EMT to 2 AC/MC cables.

Apr 01, 2008

Model 4157-DC is duplex AC/MC connector with cable range from 14/2 to 10/3 metal clad cable and ¾ in. electrical metallic tubing (EMT). Couplings' internal dimension allows conductors to pass through to EMT conduit without damaging conductor insulation. Transition fitting is suited for new construction and retrofit applications in schools and commercial buildings. Read More

Electrical Equipment & Systems, Fasteners & Hardware, Fluid & Gas Flow Equipment

Fire Alarm Boxes and Fittings provide visual identification.

Mar 13, 2008

Available in variety of sizes, Red Steel Fire Alarm Boxes and Fittings withstand harsh environmental conditions. Boxes are designed for use with Red(TM) connectors and couplings. Set screw connector joins red EMT to box, while set screw coupling joins 2 lengths of red EMT. Both concrete-tight fittings are furnished with Tri-Drive slot/Phillips/Robertson head screws and can be used for emergency... Read More

Electrical Equipment & Systems

Colored Connectors match lines of EMT conduit.

Jan 16, 2008

Complying with UL and NEC requirements, Colored EMT Fittings and Couplings allow positive visual inspection of color from inside or outside electrical box. Installers can assign colored fittings to runs with specific applications such as silver for traditional wiring systems, red for emergency circuits, blue for low voltage electronics, black for dark colored areas, orange for... Read More

Electrical Equipment & Systems

Lighting Fixtures feature vaporproof design.

Nov 09, 2007

Vaporproof Lighting Fixtures offer rugged, seamless die-cast aluminum construction that prevents moisture entry. Configurations include VAX Series box mount fixtures, VAT Series surface mount units, VAP Series right angle units, VAS Series pendant mount fixtures, and VPX Series wall mount units with box. All fixtures operate on 110/120 Vac and are rated 100 W when installed with glass globe and... Read More

Electrical Equipment & Systems

Raintight Fittings are available in steel and zinc.

Jul 17, 2007

UL-Listed EMT concrete-tight, raintight connectors feature split-type gland ring that prevents conduit from turning when tightening hex nut. Fittings enable user to connect PVC Jacketed cable by stripping back cable, unscrewing hex nut, and pushing in cable and tightening. They are available in ½-3½ in. steel, ½-2 in. zinc, and 12/2 to 8/3 for PVD Jacketed MC cable. Read More

Materials & Material Processing

Protective Strip is suited for low-voltage cabling.

Apr 20, 2007

Able to be used in exposed or concealed locations, protector strip is designed to provide physical protection for nonmetallic sheath cables or low-voltage cabling hidden in shallow recessed walls. Product comes in 3 ft length sections made of zinc electroplated .063 in. thick steel and features slots to secure cables. Protective strips are designed in accordance with 2005 NEC article 300.4... Read More

Mounting & Attaching Products

Electrical Box Extender/Insulator corrects setbacks.

Mar 20, 2007

Models BXE-100/200/300 feature continuous, smooth, nonmetallic side walls that completely enclose devices, creating insulating barrier between them and their respective metal boxes. Extender does not interfere with wiring, so no trimming is required. Mounted completely flush with wall, products fit most metallic or nonmetallic electrical boxes and accommodate GFCIs. While BXE-100 and BXE-200... Read More

Electronic Components & Devices

Expansion Couplings provide secure connections.

Feb 06, 2007

Steel expansion couplings and bonding jumper assemblies provide secure connections and grounding, regardless of temperature changes or moving parts. Designed for EMT ¾-4 in. trade sizes, steel expansion couplings compensate for up to 2 in. of conduit movement in dry locations. Bonding jumper assemblies, designed for ½-4 in. trade sizes, handle up to 4 in. expansion on EMT in addition to... Read More

Construction Equipment and Supplies

Non-Combustible Sealant withstands 3,000°F for 8 hours.

Jan 18, 2007

Water-based Firestop fire, smoke, and draft sealant fills penetrations and construction voids in residential and commercial applications. Thermal barrier adheres to most construction materials, including ceramics, composites, masonry, metal, plastic, and wood. Applied with sealant gun, odorless intumescent compound is non-toxic, non-corrosive, and environmentally safe. It is unaffected by... Read More

Electrical Equipment & Systems

Cable Connectors allow for new or old work applications.

May 23, 2006

PVC non-metallic cable connector line is designed to allow contractors to run desired length of cable into electrical box before installing connector. Model 616-NMD accepts cable ranges of one 14/2-6/2 or two 14/2-12/2, and 617-NMD accepts one 8/2-6/3 cables. Both models are used with 1 in. knockouts. For new work, connector is inserted into knockout from outside of box, and, for old work,... Read More

Electrical Equipment & Systems

Steel Cord Grips feature color-coded construction.

Apr 25, 2006

Available in ½, ¾, and 1 in. sizes, steel cord grips incorporate color-coded grommet that indicates min/max cable diameter range for which connector can be used. These 105ºC-rated neoprene sealing grommets provide strain relief and protect internal wiring connections from tension on cable or cord. Also included, steel washer reduces friction between grommet and compression nut to provide... Read More

Electrical Equipment & Systems, Fluid & Gas Flow Equipment, Mounting & Attaching Products

Compression Connectors/Couplings have raintight design.

Nov 29, 2005

Raintight Compression connectors and couplings as well as PVC jacketed MC connectors and couplings are completely assembled, UL-listed, steel (½-2 in.) and zinc (½-4 in.) fittings. Connectors feature knockout gasket that prevents water seepage into box, while connectors and couplings utilize plastic sealing rings that protect water from entering conduit. PVC-jacketed MC cable connector is... Read More

Electrical Equipment & Systems, Fluid & Gas Flow Equipment

EMT Connectors suit fire alarm applications.

Oct 28, 2005

Steel-Red Color EMT Connectors and Couplings eliminate need to paint or otherwise color fittings. Units match EMT raceways for clean looking installations. Color does not affect grounding capability as required by NEC and UL. Read More

Electrical Equipment & Systems

Fittings feature snap-in design.

Aug 11, 2005

Made of die-cast zinc, WHIPPER-SNAP(TM) Connectors feature hardened spring steel locking ring that eliminates need for locknut and installs in seconds. Double locking tabs hold connector tight in box, while additional tension tabs provide continuity and clear wire path. Push-through design eliminates snags and wire damage. WHIPPER-SNAP(TM) connectors are UL listed for grounding when installed in... Read More