Flow Transmitters

Loop-Powered Transmitters feature 2-wire output.
Flow Transmitters

Loop-Powered Transmitters feature 2-wire output.

Offered with or without dial, Differential Pressure and Flow Transmitters feature input voltage range of 9-35 Vdc and 2% FS accuracy. Users can select from differential pressure ranges of 0-5 in. H2O to 0-1,000 psi and flow ranges of 0-1 gpm to 0-10 gpm. Built for harsh industrial applications, transmitter electronics are protected by weatherproof enclosure with Class 1, Div. 1 and 2, NEMA 4X and...

Read More »
Flow Transmitters

Emerson's Smart Wireless Network Enables UK Power Generator to Monitor Treated Water Usage

AUSTIN, TEXAS (January 21, 2009) - Emerson's Smart Wireless technology is helping E.ON UK to accurately monitor and measure treated water usage, thus allowing trending and analysis to formulate target values at its Kingsnorth dual-fired power station. Using Emerson's RosemountÂ-® wireless transmitters, E.ON is now able to collect flow measurement data from new flowmeters installed throughout...

Read More »
Flow Transmitters

Flow Transmitter provides liquid, gas, and steam metering.

Designed to mount directly to most MEMFlow flow meters ranging from Â-¾-4 in. pipe sizes, non-contacting MEMFlo MFT Transmitter provides flow rate and total display, as well as 2-wire output. Electronics are completely isolated from process to provide nearly maintenance-free flow metering system. In addition to steam and gas, transmitter is suited for measuring water, sewage, brine, and...

Read More »
Bi-Directional Flow Transmitter delivers total indication.
Flow Transmitters

Bi-Directional Flow Transmitter delivers total indication.

Model 286 offers 2-phase, quadrature output that can be used to monitor flow direction. In combination with Model 121 MPU-based indicator, any of Max Machinery's 11 sizes of flow meters can create bi-directional flow metering systems. High-resolution output, with up to 1,000 ppr, combines with Max flow meters ability to operate below 1 rpm, enabling near zero flow measurement and zero crossing...

Read More »
Flow Electronics feature modular architecture.
Flow Transmitters

Flow Electronics feature modular architecture.

CAT Series accepts up to 3 different circuit boards to offer options for signal conditioning, amplification, and transmission. Microprocessor-based devices include CAT1 intelligent loop powered 4-20 mA transmitter with linearization; CAT2 signal conditioner with various output options and optional High and Low flow rate alarms; and CAT3 intelligent signal conditioner with optional alarms and...

Read More »
Flow Transmitters

Transmitter includes FOUNDATION(TM) fieldbus technology.

RosemountÂ-® 3095 MultiVariable(TM) Transmitter delivers 4 measurements from 1 device, including pressure, differential pressure, temperature, and fully compensated mass flow. Mass flow function block applies measured pressure and temperature to perform real-time flow compensation for all flow variables that could contribute to flow errors, including density, discharge coefficient, gas...

Read More »
Flow Transmitters

Transmitter measures air velocity, temperature, and volume.

Using hot film sensor element based on thin film technology, EE75 measures air speed and gas flow from 0-8,000 fpm. Unit features integral temperature compensation, and construction of sensing head minimizes impact of mounting angle on measurement results. Configuration software enables user to input duct diameter, enabling gas velocity, temperature, and volume flow to be available as analog...

Read More »
Flow Transmitters

Multivariable Transmitter measures natural gas flow rate.

Available with Modbus digital communications for remote monitoring, configuration, and calibration, Model IMV25 combines static pressure, differential pressure, and temperature measurements. Transmitter uses PCMM configurator software for setup and communicates with host processors using Modbus RTU mode through 2-wire RS-285 multidrop serial connection. Unit is configurable for DP spans up to 840...

Read More »
Flow Transmitter supports up to 14:1 flow turndown.
Flow Transmitters

Flow Transmitter supports up to 14:1 flow turndown.

Based on SuperModuleÂ-® platform, RosemountÂ-® 3051S Ultra for Flow supports scalable performance and up to 14:1 flow turndown with better than 0.5% of reading accuracy. Hermetic, all-welded SST housing meets operating requirements for harsh environments, and Coplanar(TM) process isolators allow sensor to float freely, eliminating effects of installation-induced errors.

Read More »

All Topics