Expanded Heat Exchanger Product Offering from Diversified

Expanded Heat Exchanger Product Offering from Diversified

Diversified Heat Transfer is a leading manufacturer of custom designed shell and tube heat exchangers. DHT has expanded its product offering to include plate & frame, and brazed plate heat exchangers for every heating and cooling application. Plate and frame heat exchangers are highly efficient; compact, easy to clean and economic. They are made from materials such as stainless, titanium or...

Read More »

Heat Exchanger tolerates thermal variances.

Suitable for applications involving high temperature and large temperature differentials, WPX Welded Plate Heat Exchanger can cover 6,000 square meter surface area and reach pressures up to 1,015 psi. Heat transfer elements allow minor local movements to relieve thermal stresses. Cross-counter-flow heat transfers through corrugated stamped sheets designed to optimize transfer coefficients. Heat...

Read More »

Paragon Airheater Technologies Announces Availability of High Performance Replacement Parts for Regenerative Airheaters

Innovative parts extend life, improve performance, and reduce maintenance costs of airheater CORONA, Calif., Dec. 11, 2006 - Paragon Airheater Technologies, the fastest growing manufacturer of high-performance seals and baskets for rotary, regenerative airheaters, has announced the availability of high performance replacement basketed elements for rotary, regenerative airheaters used in...

Read More »
Heat Recovery Unit provides free hot water.

Heat Recovery Unit provides free hot water.

Engineered to minimize water heating equipment load, Enviro-Pak hot water maker and heat recovery unit uses excess refrigeration energy of existing or newly installed air-conditioning or refrigeration systems in 1.5-5 ton range. Unit can be used with R-22 or R410a applications, and can provide increase in SEER for older systems up to 3 SEER points. Offered with white powder coat paint or...

Read More »

Heat and Mass Exchanger provides energy efficient cooling.

Requiring no compressor or chemical refrigerants, HMX Heat and Mass Exchanger enables water-fueled air conditioners to cool homes, office buildings, and industrial spaces without generating greenhouse gas emissions. System capitalizes on thermodynamic M-Cycle, which harnesses endless supply of atmospheric energy to drive cooling. Cooling capacity and Energy Efficiency Ratio increase along with...

Read More »

Single-Use HME Device works with tracheostomy tubes.

PortexÂ-® ThermoventÂ-® T2 Heat and Moisture Exchange (HME) Device provides humidification for spontaneously breathing patients whose upper airways are bypassed by tracheostomy tube. It includes easy-opening port for suctioning, and oxygen line connection port for supplementary oxygen. Oxygen reservoir end caps are rounded for patient comfort, while clear housing allows visualization of...

Read More »
Graphite Heat Exchanger utilizes multiple bundles.

Graphite Heat Exchanger utilizes multiple bundles.

Allowing operation in countercurrent flow regime, Model RM Multi-Tube Bundle Exchanger handles applications with close temperature approaches or temperature crosses. Bundle modules can be removed for cleaning, inspection, or replacement. Impervious graphite exchangers are used for heating and cooling corrosive chemicals such as hydrochloric acid, sulfuric acid, and phosphoric acid.

Read More »

Heat Exchanger cools computer room hot spots.

Designed for IBM 7014-T42 rack, Model 6858 Rear Door Heat Exchanger enables server density to be increased without increasing cooling requirement in computer room. Water-cooled unit removes up to 50,000 Btu/hr of heat from air exiting back of fully populated rack before it enters room. Rear door design attaches to customer-supplied water, using industry-standard fittings and couplings.

Read More »

Plate Heat Exchanger handles capacities to 15,585 gpm.

Measuring approximately 13 ft, Model T50 has 20 in. port on plate with 38 sq-ft of heat transfer area and is suited for sea cooling applications in large plants. Plate is available in low-theta, medium-theta, and high-theta versions that can be combined in 5 channel combinations to provide optimized design for specific temperature programs. Unit can be supplied with options such as reinforced...

Read More »
Heat Exchanger has door-mount design.

Heat Exchanger has door-mount design.

Able to increase server density without increasing cooling requirements, Rear Door Heat eXchanger is designed to dissipate heat generated from back of computer systems. It attaches to customer supplied water and can dissipate up to 50,000 BTUs of heat from air exiting from back of full rack of servers before it enters room. Unit fits on IBM Enterprise 42U racks.

Read More »

All Topics