Nitrogen Analyzers permit simultaneous analyses.

Nitrogen Analyzers permit simultaneous analyses.

Total Nitrogen Modules (TNM) permit simultaneous analysis of Total Nitrogen (TN) and Total Organic Carbon (TOC) in liquid samples. TNMs are available for laboratory TOC-V units or process on-line TOC-4100. Analysis time is ~4 minutes per analysis. TNM measuring range is 50 ppb to 4000 ppm for laboratory unit. Optional ASI-V autosampler holds up to 93 samples, and optional SSM-5000A Solid Sample...

Read More »
Analyzer has 3 oxidization methods.

Analyzer has 3 oxidization methods.

TOC-VW can be operated as UV/Persulfate TOC, Heated/Persulfate TOC, or as Heated-UV-Persulfate TOC system. Three oxidation methods promote rapid breakdown of difficult to oxidize compounds. Analyzer can handle particulates up to 1.6 mm in diameter, and has 0.5 ppb detection limit. NDIR detector has 5 orders of magnitude linearity. Over-range samples can be compared with up to 3 calibration curves...

Read More »
Network Tester pings LANs to check connectivity.

Network Tester pings LANs to check connectivity.

Handheld Pinger Model 60 tester can be used for installing and maintaining computer Local Area Networks running TCP/IP protocol. It uses Ping function to verify connectivity, check transmitted and received data integrity, indicate network traffic loading by measuring round trip time, and notify of duplicate IP address responses. It also provides MAC address of IP address, and warns user when...

Read More »
Oxygen Analyzer incorporates non-depleting sensor.

Oxygen Analyzer incorporates non-depleting sensor.

DF140 Oxygen Analyzer is available in ranges from 0-10 ppm to 0-25%. Sensor is fully calibrated to NIST standards, does not require frequent recalibrations, and never has to be rebuilt or replaced. Analyzer has optional NEMA 4X and NEMA 7 remote sensor enclosures for installation in Class 1, Div 1 and 2 areas. Accuracy is rated at Â-

Read More »
Aggregate Classifier is fully automatic.

Aggregate Classifier is fully automatic.

GRADEX(TM) 3000 Particle Size Analyzer provides sieve analysis for gradation of aggregate material. It eliminates transposition and calculation errors by automatically classifying and weighing each sieve fraction, and calculating and storing weight values. Data is reported to PC. GRADEX 3000 analyzes up to 13 fractions utilizing stack of standard, 12 in. diameter, half-weight, round test sieves.

Read More »

Analyzer checks amount of water in oil.

H20il Analyzer System for upstream and midstream operations offers continuous measurement of water from 0 to 100%. Knowing and controlling water/oil content improves efficiency of oil recovery, maximizes oil quality by improving dehydration process, and minimizes transport of water. System is available in 2 to 8 in. models, all with FM approval. Applications include well testing, flow station,...

Read More »
Electrochemical Sensors monitor CO, H2S and O2.

Electrochemical Sensors monitor CO, H2S and O2.

XS-R Series has three-electrode design, providing greater specificity to target gases, resistance to over exposure, and stability in presence of changing temperatures, pressures and humidity. Sensors are available for carbon monoxide, hydrogen sulfide and oxygen.

Read More »
Particle-Size Analyzer reduces costs, increases capacity.

Particle-Size Analyzer reduces costs, increases capacity.

Handling up to seven samples simulataneously, Gradex Model 1000 automates sieve analysis of dry granular material, eliminating need for operator to weigh, calculate, and record of data. Analyzer uses same rotary shaking/tapping motion as manual shaker. It accommodates six full-height or nine half-height test sieves and provides same results as manual process.

Read More »
CO2 Analyzer mounts on wall in NEMA enclosure.

CO2 Analyzer mounts on wall in NEMA enclosure.

CEA 266 infrared C02 gas analyzer comes with water and dust tight NEMA 4X enclosure, digital display readout, 0-5 Vdc and 4-20 mA outputs, self-draining water trap and dust filter, and 2 user adjustable alarms and contact relays. It is available in ranges of 0-2000 ppm, 0-5000 ppm, 0-1%, 0-2%, 0-5%, 0-10%, or 0-20%. Sample gas is continuously drawn into unit through built-in air pump....

Read More »
UV Exposure Meter displays dosage and uniformity.

UV Exposure Meter displays dosage and uniformity.

Compact, self-contained IL393UV Light Bug radiometer measures total dosage and peak irradiance of UV illumination occurring in real-time inside equipment. LCD provides immediate graphic representation of light distribution or illumination uniformity, and it holds two sets of measurements for making comparisons in real-time. It withstands intense UV irradiance and temperatures found inside curing...

Read More »