|
|
Advertisement
|
|
Plant Furnishings & Accessories ->
Equipment Enclosures
Equipment Enclosures
(Showing headlines 121 - 140) 1 2 3 4 5 6 7 8 9
|
 Clean Air Enclosures suit high-volume robotic applications.Baker Co., The
Sanford, ME 04073
Oct 31, 2003 BioPROtect® II and BioPROtect® Jr. are Class II-style clean air and containment enclosures that provide HEPA-filtered, particulate-free airflow throughout work area, protecting personnel, product, and environment. Enclosures accommodate robotic systems, ultra-centrifuges, flow cytometers, aerosol generators, and other pieces of laboratory equipment. Applications include high-throughput screening, combinatorial chemistry, immunology, and clinical research. |
Baghouse Winterizing Kits are available for retrofit.Industrial Accessories Company
Mission, KS 66202
Oct 31, 2003 Kits protect baghouse compressed air system's pulse valves and air headers from snow, ice, and freezing weather, guarding against production interruptions and plant downtime. They are custom-designed for each baghouse pulse valve header assembly and include insulated enclosure, top removal quick-release lid for service access, and heat tape. integrated thermostat maintains header/valve assembly above 32°F. |
 Window Kits suit heavy-duty electronic enclosures.Adalet
Cleveland, OH 44135 3301
Sep 18, 2003 Tempered-plate-glass window kits, offered with 304 and 316L stainless steel frames, are available for use in company's Increased Safety Terminal Enclosures (protection type e) and general-purpose NEMA Type 4, 4X, 12, and 13 enclosures. Glass window offers impact resistance. Silicone gasket provides protection against oil and water and provides dust-tight seal around perimeter of window and frame. Sizes range from 3 x 3 in. viewing area to 24 x 24 in. |
 Multi-Purpose Enclosure provides Type 1 protection.Hoffman
Anoka, MN 55303 7504
Aug 28, 2003 Offered with integral 10-gauge steel base, free-standing enclosure acts as housing solution for PLC/main control panels, power distribution cabinets, and HVAC applications in clean environments. It is available in 11 sizes from 48 x 25 x 12 in. to 84 x 36 x 24 in. Component mounting options include panel and 19 or 23 in. rack angle mounting. Offerings include removable back cover and reversible doors designed with 3-point latch and padlocking handle. |
 Custom Enclosures protect industrial equipment.Porta-King Building Systems
Earth City, MO 63045 1211
Jul 22, 2003 Suited for industrial applications, custom-designed equipment enclosures feature bi-parting door that opens in corner to facilitate moving of large equipment. Panel includes fiberglass reinforced plastic finish on lower panel sections which protects against damage and scratches from pallet jacks and other moving equipment. A solid core panelized roof improves insulation and sound control. |
 Wall Housings suit fans from 18 to 84 in.American Coolair Corp.
Jacksonville, FL 32203 2300
Jul 15, 2003 Wall Housings for CBH, CBHX, and CBC fan models are completely reversible for supply or exhaust use. They are offered with inlet hoods, discharge hoods, and shutters and come in galvanized steel, galvanized steel with 6 mil epoxy, stainless steel, and all aluminum. |
 Instrument/Meter Enclosure suits hazardous locations.EGS Electrical Group
Skokie, IL 60077
Jun 23, 2003 UL Listed and CSA Certified, Model AGUB is made of copper-free cast aluminum with corrosion-resistant finish. Precision-threaded flame path is provided between box and cover. Large cover opening allows access to electrical devices and permits fast wire splicing and pulling. O-ring gasket seals out moisture, dust, oil, and dirt for interior and exterior locations. Cover is offered with sight glass to permit viewing of instrument dial or setting. |
Rackmount Enclosure withstands shock and vibration.One Stop Systems
Escondido, CA 92029
May 13, 2003 Housing 6 hot swappable, 3.5 in. drives and two 5.25 in. drives, 2U high PCI rackmount enclosure includes vertically mounted backplane that supports PICMG-based SBC and up to 4 full-length PCI boards. Its 320 W, ATX-style power supply provides +5, +3.3, +12, and -12 V outputs, while 2 fans blow cooling air through card cage. Construction includes reinforced corners, power supply hold-downs, flush-mounted LEDs, and completely secured cables. |
 Card Cage reduces G-loads by factor of ten.Parvus Corp.
Salt Lake City, UT 84115 2913
Apr 28, 2003 Clear-anodized aluminum DuraChassis™ PC/104 enclosures integrate removable railed card cage sub-assembly designed for shock mitigation and card removal. Design secures PC/104 modules in card cage with 4 solid points of attachment. Units provide protection against shock and vibration through 59 durometer Silastic® silicone shock absorbers. Products come in 6.0, 8.0, 10.0, and 12.0 in. lengths to accommodate up to 5, 8, 11, and 14 PC/104 cards respectively. |
 Carrying Case accommodates large portable electronic devices.RoadWired, Division of Three Point Ventures, LLC
Henrietta, NY 14467
Apr 22, 2003 Podzilla is made of 1050 denier ballistic Nylon, and features winged compartment design with 3 multipurpose accessory organizers surrounding main compartment. Wings contain over 12 storage and protection elements, including elasticized slots for flash memory/media cards, bungees to secure USB or other cords, loops for batteries and film, and pockets for PC cards. Central, main compartment is fully padded on all sides and protected by oversized weather flap. |
 Instrument Housings offer expanded viewing windows.Adalet
Cleveland, OH 44135 3301
Apr 09, 2003 Series XIHMK Explosionproof Instrument Housings suit large diameter assemblies, multi-level circuit boards or wide-angle readouts and displays and have 3-9/16 in. ID. Housings are precision machined from sand-cast, copper-free aluminum, or 316 stainless steel and feature 3/4 in. NPT conduit feed-through hubs, 7/16 in. thick base for blind tapped instrument mounting holes, and 2-1/2 in. dia. glass cover. Units meet multiple certification agency requirements. |
 Air Conditioned Enclosures suit indoor/outdoor applications.EIC Solutions Inc.
Warminster, PA 18974
Apr 03, 2003 ACE Enclosures combine Thermoelectric Air Conditioners with NEMA 12, 4, and 4X enclosures that are wall, floor, and pole mounted. Enclosures keep electronics and control systems cool while protecting them from dust, dirt, and moisture. Cabinets come in 50 different sizes, plus custom sizes, in either powder coated steel or stainless steel. Fiberglass and aluminum enclosures are also available. |
Operator Interface Enclosure withstands harsh environments.Rittal Corporation
Springfield, OH 45504
Apr 01, 2003 Made of Type 304 brushed stainless steel, Premium Panel is suited for applications where high-pressure wash downs are required. With IP69K rating, enclosure provides protection against ingress of dust, jet steam cleaning from 1,160–1,450 psi, liquid temperatures to 176şF, and nozzle distances of 3.9–5.9 in. from enclosure surface. Offered with or without keyboard housing, product is available in depths of 4.72 or 8.66 in. |
 Machinery Enclosures protect sensitive equipment.Porta-King Building Systems
Earth City, MO 63045 1211
Mar 20, 2003 Using extra tall panels, modular enclosures are suited for housing large calibration or processing equipment. Environmentally cooled enclosures protect against harsh plant environments, while solid, panelized ceiling system sits directly atop walls to provide sound and climate control. Over-sized doors offer convenience in transporting materials in and out of controlled environment. Layouts can be reconfigured and moved due to enclosures' modular nature. |
 Multi-Functional Cases feature integral EMC shielding.Schroff, Inc.
Warwick, RI 02886
Feb 26, 2003
Schroff® RatiopacPRO Series, designed to IEEE1101.10 specifications, provide system designers with enclosed 19 in. sub-rack solutions. Internal framework consists of extruded aluminum rails mounted between aluminum side panels and support brackets. EMC attenuation is greater than 25 dB at 1 GHz. Symmetric design enables users to plug in modules from front or back without removal of cover plates. Units come in 3U, 4U, 6U sizes, and units with integral ventilation come in 4U, 5U, or 7U sizes.
|
 Chassis mounts in standard 19 in. racks.CyberResearch, Inc.
Branford, CT 06405 2932
Feb 18, 2003 Short-length MicroBox™ chassis offer rack-mount flanges on 3- and 5-slot units. Also mountable to any stable horizontal or vertical surface, 3-slot chassis come with 3 ISA or 2 PCI plus one PISA slot, while 5-slot models come with 5 ISA slots: 3 PCI, one PISA, and one ISA. Less than 2 RU high, 3-slot chassis come with one 3.5 in. drive bay. Measuring less than 3 RU high, 5-slot chassis come with one external and one internal 3.5 in. floppy drive bay. |
 Vibration Isolators protect embedded PC/104 electronics.Parvus Corp.
Salt Lake City, UT 84115 2913
Feb 14, 2003 Shock Rocks™, made of 59-durometer Silastic® silicone rubber material, reduce g-force frequencies on 3 axes by up to a factor of 10. Designed to attach to outside perimeter of 4 x 4 in. PC/104 railed card cage, Shock Rocks isolate all points of contact between removable aluminum card cage and surrounding enclosure, eliminating need for PCB standoffs/spacers. Up to 14 PC/104 modules can be securely held in shock/vibration-dampened card cage. |
 Enclosure suits corrosive and sanitary environments.Moore Industries International, Inc.
North Hills, CA 91343
Feb 07, 2003
Model SB Stainless Steel Enclosure offers protection for field-mounted hockey-puck units. NEMA 4X and IP66 rated, it meets standards for enclosing indoor and outdoor electric instruments in explosion-proof, dust-ignition proof, and intrinsically safe locations. Model SB installs on any surface or pipe. It is available with solid cover or glass cover for viewing instrument displays and indicators. Metric and NPT versions are available.
|
 Gas Cylinder Enclosures provide indoor and outdoor security.Atlas Welding Accessories, Inc.
Troy, MI 48099
Jan 27, 2003 Compressed Gas Cylinder Enclosures come in 3-sided wall mount unit or 4-sided floor mount unit, which are 7 ft high with roof panel. They feature 3˝ in. sweep gap and 3 ft wide door with built-in key lock. Standard sizes are 5 x 3 ft or 10 x 3 ft. Enclosures are constructed of 1 x ˝ x 1/8 in. channels and 10 gauge wire, woven into 1 x ˝ x 1˝ in. diamond mesh, and securely clinched into channel frames. Custom sizes can be supplied. |
 Explosion Proof Enclosures come with bolt-on mounting lugs.Adalet
Cleveland, OH 44135 3301
Jan 23, 2003 IP66/NEMA 4 rated units are offered with bi-directional mounting lugs that permit vertical or horizontal mounting orientation. Ductile aluminum alloy lugs adapt to irregular surfaces so lug bolts can be tightened without damaging enclosure. Offered as alternative to cast on lugs, certifications include UL Standard 1203, CSA Standard C22.2 No. 30, and ATEX 0539 Ex II 2GD. Additional certifications include Class I, Groups C, D; Class II, Groups E, F, G; and Class III. |
(Showing headlines 121 - 140) 1 2 3 4 5 6 7 8 9
|
|
|