ThomasNet News Logo
Sign Up | Log In | ThomasNet Home | Promote Your Business
 Journals
Industry Market Trends ®
Fluid & Gas Flow Journal
Machining Journal
Procurement Journal
Tech Trends Journal
 Industry News
Latest New Product News
Association & Government News
Thought Leaders
 Product News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Green & Clean
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Newsletter Archive
SME
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
Call for Contributors, Guest Writers and Submissions
How to Write an effective Press Release
Trade Associations
Electronic Components & Devices -> Signal Generators


Signal Generators







(Showing headlines 1 - 20)   more ....

Arbitrary Waveform Generator offers 65 GSa/s max sample rate.

Keysight Technologies    New Delhi 110025  India
Sep 16, 2014 Featuring up to 16 GSamples of waveform memory and instantaneous bandwidth from DC to 20 GHz, Model M8195A allows engineers to generate digital, multilevel signal scenarios and test electrical and optical links with complex modulated signals up to 32 GBaud and beyond. Unit offers up to 2 Vpp differential output voltage and adjustable DC offset in -1 to 3.3 V window. Multiple M8195A modules can be combined in system with up to 16 synchronous channels in single 5-slot AXIe chassis.

Audio Analyzer provides AES3 and S/PDIF digital I/O.

Audio Analyzer provides AES3 and S/PDIF digital I/O.

Audio Precision, Inc.    Beaverton, OR 97075
Sep 15, 2014 With typical residual THD+N of -120 dB, two analog channels of Model APx555 feature low noise and distortion, allowing sensitive measurements to be made. Unit provides 1 MHz bandwidth (mono) and FFT resolution of 1.2 million points. Generator is capable of producing low distortion sine wave signals up to 204 kHz, at high-level amplitudes up to 26 Vrms. Providing multi-mode user interface, APx500 v4.0 software allows switching between Sequence Mode and Bench Mode.

Voltage Controlled Oscillator features linear tuning.

Voltage Controlled Oscillator features linear tuning.

Z-Communications, Inc.    San Diego, CA 92126
Sep 08, 2014 Operating at 4,100–4,300 MHz with tuning voltage of 0.5–4.5 Vdc, Model V844ME36-LF provides better than 1.1:1 tuning linearity, typical tuning sensitivity of 93 MHz/V, and spectrally clean signal of -110 dBc/Hz at 100 kHz offset. Unit delivers 3 dBm of output power into 50 Ω load while operating off 5 Vdc supply and drawing 15 mA of current. Housed in MINI-14S-L package measuring 0.5 x 0.5 x 0.13 in., RoHS-compliant VCO features extended commercial temperature range of -40 to +85°C.

Ultrasound System targets research and clinical applications.

Alpinion Medical Systems    Bothell, WA 98021
Sep 08, 2014 Featuring software beamforming technology and frame rate of over 9,000 fps, E-CUBE 12R can acquire high-resolution raw RF data in real-time. System offers arbitrary waveform generation and highly customizable sequence programmability that allows researchers to manipulate all parameters, including transmit level, receive level, and transducer settings. Users can also freely process and reconstruct pre-beamformed and post-beamformed non-decimated pixel RF data in system environment.

Voltage Controlled Oscillator operates at 1,680 MHz.

Voltage Controlled Oscillator operates at 1,680 MHz.

Crystek Corp.    Fort Myers, FL 33913
Sep 05, 2014 Operating with control voltage range of 0.5~4.5 V, Model CVCO55CC-1680-1680 features typical phase noise of -117 dBc/Hz at 10 KHz offset and typical output power of +2.5 dBm. Input voltage is 5 V, with max current consumption of 20 mA. Pulling and pushing are minimized to 2 MHz and 1 MHz/V, respectively. Housed in 0.5 x 0.5 in. SMD package, oscillator is suited for digital radio equipment, fixed wireless access, satellite communications systems, and base stations.

Voltage Controlled Oscillator operates from 200-239 MHz.

Voltage Controlled Oscillator operates from 200-239 MHz.

Crystek Corp.    Fort Myers, FL 33913
Aug 12, 2014 Operating with control voltage range of 0.5~4.5 V and typical output power of +8.5 dBm, Model CVCO55FL-0200-0239 features typical phase noise of -123 dBc/Hz at 10 KHz offset. Input voltage is 5 V with max current consumption of 25 mA, and pulling and pushing are minimized to 0.5 MHz and 0.5 MHz/V, respectively. Housed in 0.5 x 0.5 in. SMD package, VCO is suited for digital radio equipment, fixed wireless access, satellite communications systems, and base stations.

RF Reference Sources calibrate spectrum analyzers.

RF Reference Sources calibrate spectrum analyzers.

Fluke Calibration    Everett, WA 98203
Aug 08, 2014 Designed specifically for RF calibration, Models 96270A and 96040A provide accurate signal delivery direct to UUT input. Units feature integrated frequency counter rated at 300 MHz and 50 MHz, respectively, while Model 96270A also includes dual power meter readout, eliminating need for additional instruments. Model 96270A covers more than 80% of test points required for calibrating spectrum analyzer models below 27 GHz, and nearly all spectrum analyzers of any frequency range.

Crystal Units offer optimized frequency tolerance.

Crystal Units offer optimized frequency tolerance.

Murata Electronics North America, Inc.    Smyrna, GA 30080
Aug 04, 2014 With frequency tolerance of ±20 ppm at +25°C, and frequency shift by temperature of ±20 ppm max from -30 to +85°C, XRCGB-F-P Series is suitable for use in 802.1 wireless connectivity designs using protocols such as Bluetooth Low Energy and ZigBee. Units are constructed in 2016 package, making them ideal candidates for second sourcing.

Waveform Monitors, Rasterizers support 4K requirements.

Waveform Monitors, Rasterizers support 4K requirements.

Tektronix, Inc.    Beaverton, OR 97077
Jul 31, 2014 Eliminating need to procure hardware replacements in order to shoot, prepare, and deliver 4K programming, WFM8200 and WFM8300 waveform monitors and WVR8200 and WVR8300 rasterizers can be upgraded via software to support 4K. Products can perform range of 4K measurements, including 4-tile displays of waveform, picture, vector, gamut, and eye diagram for YPbPr formats. Measurement capabilities lets users reduce time required to isolate, diagnose, and remedy system issues and design faults.

Voltage Controlled Oscillator operates at 2,756 MHz.

Voltage Controlled Oscillator operates at 2,756 MHz.

Crystek Corp.    Fort Myers, FL 33913
Jul 25, 2014 With output power of +4 dBm and control voltage range of 0.5~4.5 V, Model CVCO55CC-2756-2756 features typical phase noise of -116 dBc/Hz at 10 KHz offset. Input voltage is 5 V, with max current consumption of 28 mA. Pulling and Pushing are minimized to 1 MHz and 0.2 MHz/V, respectively. Housed in 0.5 x 0.5 in. SMD package, oscillator is suited for digital radio equipment, fixed wireless access, satellite communications systems, and base stations.

Tight Stability Clock Oscillators come in two package sizes.

Tight Stability Clock Oscillators come in two package sizes.

IQD Frequency Products    San Jose, CA 95131
Jul 22, 2014 Respectively supplied in 2.5 x 2.0 mm and 3.2 x 2.5 mm ceramic packages, IQXO-445 series and IQXO-430 series deliver frequency stabilities as low as ±10 ppm over full -40 to +85°C range. Both series are available over 4–54 MHz range, consume 3.1 mA at 40 MHz, and offer phase noise performance of -145 dBc/Hz at 10 kHz offset. Output is CMOS-compatible with up to 15 pF load, and both models include tri-state capability. Available supply voltages are 2.5, 3.0, or 3.3 V.

Clock Generators suit networking and storage applications.

Microsemi Corporation    Irvine, CA 92614
Jul 21, 2014 Supplied in 5 x 5 mm package, Models ZL30250 and ZL30251 offer ultra-low jitter of 160 fs and any-to-any frequency conversion with 0 ppm error. Generators feature up to 3 differential outputs, up to 6 CMOS outputs, and 3 universal clock inputs that connect to any signal format at any voltage. Devices can generate PCIe clock signals with or without spread-spectrum modulation. In numerically controlled oscillator mode, output frequencies can be controlled with high resolution by software.

Voltage Controlled Oscillator delivers +5.5 dBm output.

Voltage Controlled Oscillator delivers +5.5 dBm output.

Crystek Corp.    Fort Myers, FL 33913
Jul 18, 2014 Housed in industry-standard 0.5 x 0.5 in. SMD package, Model CVCO55BE-1000-2000 operates from 1,000–2,000 MHz with control voltage range of 1.0~20 V, and features typical phase noise of -95 dBc/Hz at 10 KHz offset. Input voltage is 10 V with maximum current consumption of 25 mA. Pulling and Pushing are minimized to 7.5 MHz and 2.5 MHz/V, respectively, and second harmonic suppression is -10 dBc typical.

Waveform Creation Software accelerates device development.

Agilent Technologies, Inc.    Santa Clara, CA 95051
Jul 10, 2014 Targeting developers of radars, satellite communications, military radios, and next generation of DOCSIS 3.1 cable modems, M9099 Waveform Creator v2.0 provides waveform segment types that can be combined into multiple tracks and aggregated into one composite waveform. Capabilities let users build or import various signals, mix them together, and add IQ impairments and noise to simulate real-world environments. Drag-and-drop interface facilitates creation of complex composite waveforms.

Function/Arbitrary Waveform Generator has 2 independent channels.

Function/Arbitrary Waveform Generator has 2 independent channels.

B&K Precision Corporation    Yorba Linda, CA 92887
Jun 24, 2014 Dual-channel models 4063, 4064, and 4065 respectively generate sine waveforms up to 80, 120, and 160 MHz. Featuring pulse generator and 512k-point arbitrary waveform generator on one channel, these instruments can generate pulses with <100 ps jitter and output 12 nsec width pulses at frequencies as low as 0.1 Hz. Other features include adjustable rise and fall times, rotary control knob, numeric keypad, function keys, built-in counter, Sync output, and trigger I/O terminal.

Digital Delay Pulse Generators have compact, wireless design.

Quantum Composers, Inc    Bozeman, MT 59718
Jun 24, 2014 Along with Bluetooth® wireless technology, plug-and-play Emerald 9250 Digital Delay Pulse Generators feature 5 psec timing resolution, 15 psec channel to channel jitter, and low Period Jitter of <40 psec RMS. Custom software application, included, lets users program instrument using GUI on PC. With full functionality offering range of complex pulse trains, these reusable products serve such applications as LIDAR, LIBS, PIV, and university physics/chemistry labs.

All-in-One Instrument suits circuit debugging and validation.

National Instruments Corp.    Austin, TX 78759-3504
Jun 24, 2014 Featuring 10 x 7.5 x 2.9 in. benchtop design, VirtualBench integrates mixed-signal oscilloscope, function generator, digital multimeter, programmable DC power supply, and digital I/O. Users interact with VirtualBench through software applications that run on PCs or iPads. In addition to wireless connectivity, system offers consolidated view of multiple instruments, visualization on large multitouch display, and quick functionality to save data and screenshots.

Analog Radio Test Set uses digital measurement technology.

Rohde & Schwarz GmbH & Co      Germany
Jun 20, 2014 Designed for 100 W continuous input power and 150 W peak input power, R&S CMA180 enables manufacturers and service technicians to test analog radios in 100 kHz to 3 GHz frequency range. Unit uses integrated ARB generator for software implemented test signal generation and enables users to generate any output signal with bandwidth up to 20 MHz. Engineers can also use instrument's integrated sequencer to configure and run automatic test sequences.

OCXO delivers ±0.2 ppb frequency stability.

OCXO delivers ±0.2 ppb frequency stability.

IQD Frequency Products    San Jose, CA 95131
Jun 13, 2014 Covering 10–40 MHz range, IQOV-164 series comes in 5-pin euro package measuring 36 x 27 x 13.5 mm and delivers ±0.2 ppb frequency stability from -20 to +70°C or ±0.5 ppb from -30 to +75°C. Frequencies are available up to 100 MHz with stability of ±10 ppb from -30 to +75°C. Consuming 7.0 W max during 3 min warm up, series operates from 3.3 V supply and offers output that can be specified as HCMOS, 15 pF load, or Sinewave into 50 Ω load. Phase noise is typ -158 dBc/Hz at 100 kHz offset.

RF Upconverter extends frequency of vector signal generator.

Rohde & Schwarz GmbH & Co      Germany
Jun 12, 2014 Available as pure CW upconverter or as upconverter for I/Q-modulated signals, R&S SGU100A extends frequency range of R&S SGS100A vector signal generator from 12.75 GHz to 20 GHz. By combining instruments, users can generate vector signals continuously from 80 MHz to 20 GHz. Devices act as single unit with one I/Q input and one RF output, and can be controlled remotely or manually. When using CW version, combination is optimal for multitone applications requiring phase coherence.




(Showing headlines 1 - 20)   more ....


Home  |  My ThomasNet News®  |  Industry Market Trends®  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2014 Thomas Publishing Company. All Rights Reserved.
Terms of Use - Privacy Policy