Logic Analyzer Probe has 7 x 22 mm footprint .

Logic Analyzer Probe has 7 x 22 mm footprint .

Model E5396A is 17-channel, single-ended connectorless soft-touch probe compatible with company's logic analyzers that use 40-pin connector interface. Model E5398A soft-touch probe is compatible with logic analyzers that use 90-pin connector interface. Spring-pin technology ensures reliable connection without need for special cleaning or surface finishes of probe pads. Probes suited for...

Read More »

Logic Analyzer offers 3 modular mainframe choices.

Series 16900, powered by Windows(TM) XP, offers 3 modular mainframes that feature user interface and debug support for microprocessors and buses. Hosted mode allows users to host logic analysis application software and provides remote access and control. Models 16900A and 16902A mainframes can operate in stand-alone or multi-frame configurations. Module provides 4 GHz timing, 250 ps sampling...

Read More »
Analyzer detects hydrogen sulfide from 0-100 ppm.

Analyzer detects hydrogen sulfide from 0-100 ppm.

Model 4400 In-Stream Analyzer continuously verifies Hydrogen Sulfide content of natural gas streams to help guard against corrosive effects of H2S on compressors, pipelines, and process equipment. There are no tapes to replace, no conditioning solutions, no mechanical stream blenders to calibrate, and no hazardous material to dispose. Calibration requires only external application of span gas and...

Read More »

Blade tests signal breaks and router stress.

Eight-port T1, E1, J1 Blade, for modular IntellaPatch physical layer switch system, allows network management engineers to run interoperability and automation tests on T1 equipment, as well as European and Japanese standards. Engineers can utilize T1 blade to simulate specific carrier signal breaks and monitor effect they produce on front-end equipment. Multicasting abilities are suited for...

Read More »
Field-Portable Analyzer troubleshoots optical networks.

Field-Portable Analyzer troubleshoots optical networks.

Utilizing Jones Matrix Eigenanalysis method, Model N3909A measures polarization mode dispersion and differential group delay to provide information about optical fiber's useable bandwidth. By knowing DGD behavior, faults can be identified and isolated, cutting time required to fix network problems. Analyzer works over wavelength range of 1,520-1,630 nm with PMD accuracy of 50 fs. It exhibits...

Read More »
Serial Protocol Tester features graphical user interface.

Serial Protocol Tester features graphical user interface.

Model E2960A uses GUI to reduce setup time of PCI Express transactions to test designs. GUI offers menu display of exerciser's CAPI capabilities, and allows users to select experience level that limits number of capabilities displayed. Users can set up single packets or sequences or blocks of packets, I/O memory reads and writes, configuration reads and writes, and any type of message.

Read More »
Gas Analyzers feature dual ADC architecture.

Gas Analyzers feature dual ADC architecture.

Titan FTIR Systems provide real-time, multi-component extractive gas phase analysis. Spectrometer is packaged with externally-mounted, corrosion-resistant gas cells, with cell pathlengths ranging from 1 cm to 30 m. Thermal isolation from spectrometer allows operation from ambient to 240Â-

Read More »
Moisture Analyzer offers 250 ppt sensitivity.

Moisture Analyzer offers 250 ppt sensitivity.

Tunable Diode Laser Absorption Spectroscopy Moisture Analyzer measures moisture levels in gaseous hydrochloric acid with lowest detection level of 1.0 ppb. Governed by Beer's Law, measuring intensity of laser before and after absorption by moisture allows user to determine number of moisture molecules in sample. HCI does not interfere with measurement and there is no beam splitting for reference...

Read More »
NIR System suits powder blending applications.

NIR System suits powder blending applications.

Fully Integrated NIR System monitors blend homogeneity and end-point determination during powder blending operations in real-time. Fully closed, turnkey system eliminates physical sampling requirements and incorporates NIR spectroscopy with 21CFR Part 11 compliant software that remotely transfers immediate, reliable data to PC. System employs vibration-resistant design and prevents contact with...

Read More »
Process Oxygen Analyzers utilize coulometric sensors.

Process Oxygen Analyzers utilize coulometric sensors.

Platinum Series DF-310 general-purpose analyzer can be separated into components or housed in one enclosure. Unaffected by temperature, it is available in ranges from 0-500 ppb to 0-25% and includes RS232 and RS485 communication capabilities and non-depleting coulometric sensor. Model DF-320 has electronics that meet Class 1, Div. II requirements, while DF-330 uses solid-state coulometric sensor...

Read More »
Fresh Air Intake Designed to Meet ASHRAE 62.2 standards
Sponsored

Fresh Air Intake Designed to Meet ASHRAE 62.2 standards

Alan Manufacturing has a long history of developing innovative solutions for HVAC applications. With over 1,000 product designs under our belt, we have gained a reputation as the go-to source for HVAC dampers, hardware, duct supports, zone control systems, and much more. Adding to this extensive list of achievements we now announce the release of our new line of Fresh Air Intake products. Designed to meet ASHRAE 62.2 standards, they are the most robust and high-performance product of their kind. See our video to learn more.

Read More »