Dwyer Instruments, Inc.

Differential Pressure Transmitter has explosionproof design.
Electrical Equipment & Systems

Differential Pressure Transmitter has explosionproof design.

Series 3100 Smart Pressure Transmitter is microprocessor-based device with flexible pressure calibration and push button configuration. Unit is programmable using HART® Communication and can be configured for differential pressure or level applications with zero and span buttons. In event of shutdowns or power loss, EEPROM stores configuration settings as well as sensor correction coefficients....

Read More »
Differential Pressure Transmitter has explosionproof design.
Electrical Equipment & Systems

Differential Pressure Transmitter has explosionproof design.

Series 3100 Smart Pressure Transmitter is microprocessor-based device with flexible pressure calibration and push button configuration. Unit is programmable using HART® Communication and can be configured for differential pressure or level applications with zero and span buttons. In event of shutdowns or power loss, EEPROM stores configuration settings as well as sensor correction coefficients....

Read More »
Carbon Monoxide Detector-Transmitters provide 60 sec response time.
Electrical Equipment & Systems

Carbon Monoxide Detector-Transmitters provide 60 sec response time.

Available in wall mount or duct mount configurations, Series CMT detects and transmits low concentrations of carbon monoxide inside parking garage or loading dock. Units feature 0-125 ppm range with ±2.5% accuracy and ±1% repeatability. Universal current and voltage outputs are field selectable and match most common building management controllers. Optional relay and alarm buzzers, offered on...

Read More »
Carbon Monoxide Detector-Transmitters provide 60 sec response time.
Electrical Equipment & Systems

Carbon Monoxide Detector-Transmitters provide 60 sec response time.

Available in wall mount or duct mount configurations, Series CMT detects and transmits low concentrations of carbon monoxide inside parking garage or loading dock. Units feature 0-125 ppm range with ±2.5% accuracy and ±1% repeatability. Universal current and voltage outputs are field selectable and match most common building management controllers. Optional relay and alarm buzzers, offered on...

Read More »
Vane Operated Flow Switch features magnetic linkage.
Electrical Equipment & Systems

Vane Operated Flow Switch features magnetic linkage.

Used to start and stop electronic operated equipment when flow or no-flow conditions occur, Series V7 has weatherproof (NEMA 4X) design, is UL 353-approved, and is rated to 250 psi and 250°F. Magnetic operation is dependable, with no mechanical linkages or seals to wear or leak, and Lower body is machined solid metal bar stock to ensure that there are no leak points. Also, Rigid vane design is...

Read More »
Vane Operated Flow Switch features magnetic linkage.
Electrical Equipment & Systems

Vane Operated Flow Switch features magnetic linkage.

Used to start and stop electronic operated equipment when flow or no-flow conditions occur, Series V7 has weatherproof (NEMA 4X) design, is UL 353-approved, and is rated to 250 psi and 250°F. Magnetic operation is dependable, with no mechanical linkages or seals to wear or leak, and Lower body is machined solid metal bar stock to ensure that there are no leak points. Also, Rigid vane design is...

Read More »
Temperature Sensors target building management systems.
Sensors, Monitors & Transducers

Temperature Sensors target building management systems.

With temperature limits of -40 to 302°F, Series TE monitors air or water temperature throughout building management system or air handler unit. Flanged duct sensors monitor supply or return air and provide thermistor or RTD output to digital controller, while immersion sensors, supplied with compression fittings, monitor hot or chilled water lines throughout building. For variable air volume...

Read More »
Temperature Sensors target building management systems.
Sensors, Monitors & Transducers

Temperature Sensors target building management systems.

With temperature limits of -40 to 302°F, Series TE monitors air or water temperature throughout building management system or air handler unit. Flanged duct sensors monitor supply or return air and provide thermistor or RTD output to digital controller, while immersion sensors, supplied with compression fittings, monitor hot or chilled water lines throughout building. For variable air volume...

Read More »

All Topics