ThomasNet Home   |   Promote Your Business
Home  |   My ThomasNet News®  |   Industry Market Trends  |   Submit Release  |   Advertise  |   About Us May 26, 2012  
 Sections
Latest New Product News
Industry Market Trends
Green & Clean
Association & Government News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
AMT/IMTS
PROCESS EXPO/FPSA 2011
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP
Sensors Monitors & Transducers -> Sensors & Detectors -> Flame Detectors


Flame Detectors




(Showing headlines 1 - 20)   more ....
Flame Detector monitors entire flame spectrum to verify alarms.

Flame Detector monitors entire flame spectrum to verify alarms.

NOTIFIER Fire Systems    Northford, CT 06472
May 23, 2012 Used in commercial and industrial applications, Fire Sentry units integrate with any version of ONYX Series fire alarm systems for detection of true fire emergencies. Series of algorithms accelerate detection of real fire event while minimizing false alarms. In addition to monitoring for spikes in radiant energy of flame, detectors monitor entire flame spectrum for inconsistencies to verify alarm. Units protect against fires from hydrocarbon and non-hydrocarbon gases in all conditions.

Combination Fire/CO Detector meets CO legislation requirements.

Combination Fire/CO Detector meets CO legislation requirements.

Gamewell-FCI    Northford, CT 06472
Apr 24, 2012 Able to verify true emergency and deter false alarms, 4-Warn/CO detector incorporates sensing elements for smoke, CO (carbon monoxide), flame, and heat. Addressable sensing technology meets CO detection legislation in all 50 states. As part of E3 Series® fire alarm and emergency communications system from Gamewell-FCI, local audio signals from detector's B200S sounder base can be automatically silenced when live and pre-recorded emergency communications are delivered via main system.

Intelligent Fire Systems combine flexibility, scalability.

Intelligent Fire Systems combine flexibility, scalability.

Siemens Building Technologies, Inc.    Buffalo Grove, IL 60089
Mar 02, 2012 Cerberus(TM) PRO and Desigo(TM) fire system panels and smoke detectors feature components that may be adapted to meet new conditions. Integrated in both systems, ASAtechnology(TM) is immune to deceptive phenomena and fosters early fire detection. Control panels are networkable, and up to 16 panels can be connected using peer-to-peer networking. Other features include integrated degrade mode, application-specific detection profiles, dual optical sensors, and independent CO detection.

Combination Smoke and CO Detector minimizes nuisance alarms.

Combination Smoke and CO Detector minimizes nuisance alarms.

NOTIFIER Fire Systems    Northford, CT 06472
Sep 19, 2011 Part of ONYX Series fire alarm system, IntelliQuad(TM) PLUS combines 4 sensing elements for smoke, CO, light/flame, and heat to quickly verify true fire or CO emergency. Separate signals for CO and smoke allow for ONYX systems to respond appropriately based on event type. Combined with addressable B200S sounder base, IntelliQuad PLUS serves as all-in-one detection and notification unit. Applications include hotels, college dorms, healthcare facilities, apartments, and military housing.

Gas, Flame Detection System is solar-powered and wireless.

Gas, Flame Detection System is solar-powered and wireless.

Net Safety Monitoring Inc.    Calgary, AB T1Y7J7  Canada
May 19, 2011 To promote flexibility, SiteShield Detection System can be configured and reconfigured for any site-specific energy demands, environmental conditions, and safety requirements. Offering simultaneous gas and flame detection, autonomous unit is available in stand-alone, dual-sensor detector configuration or in networked system. It can communicate with 16 remote sensors (expandable) from one controller, and detectors may be added/subtracted to network at any time without going offline.

Flame Detector is designed for easy installation.

Flame Detector is designed for easy installation.

General Monitors    Lake Forest, CA 92630
Feb 22, 2010 Combining multi-spectrum infrared sensor array with neural network technology processing, FL4000H delivers reliable flame monitoring with detection range of 230 ft and field of view of 100° @ 100 ft. Design accelerates insertion of cable into base of unit, permitting placement of detector in tight areas. MSIR sensor array and NNT function together as adaptive and intuitive decision-making mechanism, promoting reliable discrimination between actual flames and false alarms.

Flame Ionization Detector delivers accurate hydrocarbon measurement.

Servomex Group Ltd    Crowborough East Su TN6 3DU  United Kingdom
Nov 24, 2009 Servomex SERVOPRO FID provides 100 ppb resolution hydrocarbon measurement, with all flow electronically and temperature regulated. It includes Ethernet/Internet connectivity, allowing users to check parameters or troubleshoot unit offsite. Device's logarithmic amplifier minimizes drift and thermal noise. Lock Range function allows operator to fix unit within desired range, while automatic ranging feature changes measurement parameters according to impurities detected.

UV-Based System deters illegal in-facility smoking.

UV-Based System deters illegal in-facility smoking.

Amjo Corp    Cincinnati, OH 45069-8304
Sep 24, 2009 Suited for buildings in cities and states where it is illegal for employees to smoke, CatchaSmoker series uses UV flame detector technology to catch smokers in offices and factory bathrooms. Technology detects smoker lighting up and alerts management, either with loud alarm or totally silent/stealth alarm, via building-wide paging system. Installation can be accomplished by regular maintenance staff in less than 1 hr per location.

Flame Detectors are available with HART communications.

Flame Detectors are available with HART communications.

General Monitors    Lake Forest, CA 92630
Sep 17, 2009 Flame detectors FL3100H (UV/IR) and FL3101H (UV-only) detect fires and provide alarm outputs directly from detector while maintaining false alarm immunity. In addition to process variable, HART protocol permits access to device configuration, diagnostics, as well as maintenance and alarm records. Features include continuous optical path monitoring, 4-20 mA stepped output, 3 SPDT high current programmable relay outputs, and RS-485 serial output with Modbus RTU protocol.

Smoke Detector offers early fire detection, localization.

Smoke Detector offers early fire detection, localization.

Bosch Corp.    Charleston, SC 29418
Jun 17, 2009 Protecting areas up to 400 m², 420 Series Aspirating Smoke Detector TM features 10-digit bar graph for monitoring smoke pollution and utilizes LSN improved technology that accommodates currents to 1,500 mA at distances to 3,000 m. ROOM-IDENT feature can individually identify up to 5 rooms and accelerates tracking down of fire source in 4 phases. Intelligent signal processor discerns real/false alarms, and results are displayed on unit itself and Bosch Modular Fire Panel 5000 Series.

Safety Surveillance System works automatically.

Safety Surveillance System works automatically.

Detector Electronics Corp.    Minneapolis, MN 55438
May 18, 2009 With Class I, Div. 1 and NEMA 4X approvals from FM, CSA, CE, and ATEX, xWatch® camera and surveillance system automatically detects and records safety incidents for remote or local viewing. System enables immediate viewing of industrial hazards remotely via configurable IP address, and record and review incidents for event analysis. Flame detector with camera views same expanse, and continuous, real-time video captured provides operator with surveillance capabilities during normal operation.

Optical Flame Detectors are explosion proof.

Optical Flame Detectors are explosion proof.

Spectrex, Inc.    Cedar Grove, NJ 07009
Jan 16, 2009 Designed to protect municipal/industrial waste disposal facilities, SharpEye 40/40I optical flame detectors are fitted with heated window to withstand harshest of conditions, and HART output to offer quality information during installation or maintenance. Detectors are Hazardous Area approved (FM/ATEX/IECEx/CSA) for location in zone I areas and 3rd party performance approved (EN54-10, FM, DNV). Product, when placed along edge of waste pit, enables continuous monitoring of waste pit.

Optical Flame Detectors have explosion-proof design.

Optical Flame Detectors have explosion-proof design.

Spectrex, Inc.    Cedar Grove, NJ 07009
Dec 19, 2008 Addressing fire and explosion hazards in bio-fuel plants, SharpEye 40/40 series includes IR, UV, UV/IR, IR3, and multi-spectral flame detectors with false activation immunity. Sensing distances reach 135 ft, and HART capabilities enable digital communications. Sealed electronics protect integrity of unit when open and heated window prevents condensation in humid environments. Additional protection is provided against hydrocarbon-based and water vapors.

Flame Ionization Detector measures methane gas.

Flame Ionization Detector measures methane gas.

Photovac Inc.    Waltham, MA 02451 1166
Sep 10, 2008 Meeting/exceeding requirements for EPA Federal Reference Method 21 for fugitive gas emissions, MicroFID measures methane in landfill gas, while non-methane components can be measured by adding snap-on charcoal filter capsule. Single tutor key prompts operator through basic operations, and critical data is displayed in less than 3 sec. Unit provides datalogging capability so readings can be stored and downloaded to computer for subsequent analysis and record-keeping purposes.

Smoke Detector uses crystal-controlled wireless technology.

NAPCO Security Group    Amityville, NY 11701
Aug 13, 2008 Enabling precision detection of even minute particles produced by clean-burning fires, GEM-SMK can detect all types of fires including paper, wood, gasoline, polystyrene, and smoldering fires. Photoelectric smoke detector eliminates need for home and business owners to run wires throughout their properties. It includes batteries with 5 yr life, mounting kit, and built in LED status indicator that alerts users when their battery is low or device is in need of cleaning.

Detector reduces risk of gas leak and fire ignition hazards.

General Monitors    Lake Forest, CA 92630
Aug 04, 2008 Designed for rapid detection of pressurized hydrogen leaks in vessels and pipes in open and ventilated areas, Gassonic Observer can detect leak initiation regardless of ventilation rate, gas dilution, or direction of leak, without gas having to make physical contact with sensor element. It has detection radius for hydrogen up to 8 m at leak rate of 0.01 kg/sec. Senssonic(TM) integrated acoustic self-test periodically verifies integrity of electronic circuitry and operation of acoustic sensor.

High-Temp UV Flame Detector responds rapidly to fires.

High-Temp UV Flame Detector responds rapidly to fires.

General Monitors    Lake Forest, CA 92630
May 07, 2008 Able to recognize fire within 100 msec, FL3111HT UV Flame Detector senses flames only in UV spectral range, operates in temperatures up to 257ºF, and has 4-20 mA stepped output. Design incorporates continuous optical path monitoring (COPM) technology, which performs self-checks for optical path integrity and electronics once every minute to ensure proper operation. Electronics, fully separated from Exe wire compartment, are contained within SS, explosion-proof housing.

Flame Detector features sealed electronic and sensor section.

Flame Detector features sealed electronic and sensor section.

Spectrex, Inc.    Cedar Grove, NJ 07009
Jun 22, 2007 SharpEye 20/20SI Triple IR Flame Detector has main section sealed to protect electronics and sensors from moisture during commissioning and maintenance. Modbus protocol is standard for RS-485 output, and microprocessor design allows for field programmability, minimizing false alarms. Factory settings can be updated before installation using PDA or laptop. Optical detector is available in FM and ATEX versions in aluminum or stainless steel housing.

Visual Flame Detector is suited for oil and gas industry.

MICROPACK Detection (Americas) Inc.    Fort Collins, CO 80526
Jun 19, 2007 Utilizing True Flame visual flame detection technology, Model FDS-301 detects fires in presence of sunlight, rain, fog, and hot objects. It offers false alarm immunity and can detect 10 kW hydrocarbon pool fire up to 144 ft within 90° cone of vision, indoors and outdoors. Interfaced to MICROPACK Control System or plant wide distributed control system, unit provides operator with full display and alarm handling facilities as well as live color video images.

Flame Scanner utilizes discrimination techniques.

Flame Scanner utilizes discrimination techniques.

Hamworthy Peabody Combustion Inc.    Shelton, CT 06484
May 25, 2007 Able to sense presence and condition of flames, SmartScan(TM) 121 combines sensor technology and microprocessor control to discriminate between adjacent flames, fireballs, and radiating surfaces. Unit operates over -40 to +140ºF range and offers bar graph display as well as fuel select input for 2 fuel parameters. Suited for coal, oil, gas, solid, and non-standard fuel scanning, unit has online lens cleaning capability and is resistant to momentary power outages.




(Showing headlines 1 - 20)   more ....



 Latest Products in the News


Net Safety Monitoring Inc.  - February 3, 2010
Net Safety Monitoring Offers 'Lowest Power Possible' on Flame Detectors and Fixed Gas Detection

Net Safety Monitoring Inc.  - December 25, 2009
Net Safety Monitoring Announces an Innovative Solution for the Hart Communication Protocol with our Entire Line of Explosion Proof Flame Detectors

Net Safety Monitoring Inc.  - December 10, 2009
Net Safety Monitoring Flame and Gas Detectors Receive SIL2 Qualification

Scott Safety  - July 17, 2009
Scott Health & Safety's FLAMEVision FV300 Wins Product Innovation Award at Firex Show

Honeywell International, Inc.  - June 17, 2009
Honeywell Selected to Install Fire & Gas Detection System at BTC Pipeline Terminal in Ceyhan


More Products in the News...

Home  |  My ThomasNet News®  |  Industry Market Trends  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2012 Thomas Publishing Company
Terms of Use - Privacy Policy