 Flame Ionization Detector measures methane gas.Photovac Inc.
Waltham, MA 02451 1166
Sep 10, 2008
Meeting/exceeding requirements for EPA Federal Reference Method 21 for fugitive gas emissions, MicroFID measures methane in landfill gas, while non-methane components can be measured by adding snap-on charcoal filter capsule. Single tutor key prompts operator through basic operations, and critical data is displayed in less than 3 sec. Unit provides datalogging capability so readings can be stored and downloaded to computer for subsequent analysis and record-keeping purposes.
|
Smoke Detector uses crystal-controlled wireless technology.NAPCO Security Group
Amityville, NY 11701
Aug 13, 2008
Enabling precision detection of even minute particles produced by clean-burning fires, GEM-SMK can detect all types of fires including paper, wood, gasoline, polystyrene, and smoldering fires. Photoelectric smoke detector eliminates need for home and business owners to run wires throughout their properties. It includes batteries with 5 yr life, mounting kit, and built in LED status indicator that alerts users when their battery is low or device is in need of cleaning.
|
Detector reduces risk of gas leak and fire ignition hazards.General Monitors
Lake Forest, CA 92630
Aug 04, 2008
Designed for rapid detection of pressurized hydrogen leaks in vessels and pipes in open and ventilated areas, Gassonic Observer can detect leak initiation regardless of ventilation rate, gas dilution, or direction of leak, without gas having to make physical contact with sensor element. It has detection radius for hydrogen up to 8 m at leak rate of 0.01 kg/sec. Senssonic(TM) integrated acoustic self-test periodically verifies integrity of electronic circuitry and operation of acoustic sensor.
|
 High-Temp UV Flame Detector responds rapidly to fires.General Monitors
Lake Forest, CA 92630
May 07, 2008
Able to recognize fire within 100 msec, FL3111HT UV Flame Detector senses flames only in UV spectral range, operates in temperatures up to 257ºF, and has 4-20 mA stepped output. Design incorporates continuous optical path monitoring (COPM) technology, which performs self-checks for optical path integrity and electronics once every minute to ensure proper operation. Electronics, fully separated from Exe wire compartment, are contained within SS, explosion-proof housing.
|
 Flame Detector features sealed electronic and sensor section.Spectrex, Inc.
Cedar Grove, NJ 07009
Jun 22, 2007
SharpEye 20/20SI Triple IR Flame Detector has main section sealed to protect electronics and sensors from moisture during commissioning and maintenance. Modbus protocol is standard for RS-485 output, and microprocessor design allows for field programmability, minimizing false alarms. Factory settings can be updated before installation using PDA or laptop. Optical detector is available in FM and ATEX versions in aluminum or stainless steel housing.
|
Visual Flame Detector is suited for oil and gas industry.MICROPACK Detection (Americas) Inc.
Fort Collins, CO 80526
Jun 19, 2007
Utilizing True Flame visual flame detection technology, Model FDS-301 detects fires in presence of sunlight, rain, fog, and hot objects. It offers false alarm immunity and can detect 10 kW hydrocarbon pool fire up to 144 ft within 90° cone of vision, indoors and outdoors. Interfaced to MICROPACK Control System or plant wide distributed control system, unit provides operator with full display and alarm handling facilities as well as live color video images.
|
 Flame Scanner utilizes discrimination techniques.Hamworthy Peabody Combustion Inc.
Shelton, CT 06484
May 25, 2007
Able to sense presence and condition of flames, SmartScan(TM) 121 combines sensor technology and microprocessor control to discriminate between adjacent flames, fireballs, and radiating surfaces. Unit operates over -40 to +140ºF range and offers bar graph display as well as fuel select input for 2 fuel parameters. Suited for coal, oil, gas, solid, and non-standard fuel scanning, unit has online lens cleaning capability and is resistant to momentary power outages.
|
 Flame Detector offers false alarm immunity.General Monitors
Lake Forest, CA 92630
May 11, 2007
Incorporating neural network technology, Multi-Spectral Infrared FL4000 helps process and plant engineers protect people, equipment, and facilities from hydrocarbon flame sources. Unit offers extended range up to 230 ft and wide field-of-view characteristics of 100° at 50 ft. HART communications permit remote process variable interrogation, cyclical access to process data, parameter setting, and diagnostics. Unit also includes built-in COPM, self-test feature, and serial ports.
|
 Programmable Detector senses invisible hydrogen flames.Spectrex, Inc.
Cedar Grove, NJ 07009
Jan 29, 2007
Designed for detecting water vapor at ranges to 100 ft, model 20/20SH features optical sensors and filters that offer optimal degree of spectral matching to radiant energy emitted by hydrogen fire and lowest degree of matching to non-fire stimuli. Programmable algorithms check ratio and correlation of data received by optical sensors. Applications include facilities that use hydrogen fuel cells, hydrogen gas generators, and hydroxyfuels.
|
 IR Flame Detector is immune to false alarms.General Monitors
Lake Forest, CA 92630
Jan 12, 2006
Combining optical Multi-Spectral IR (MSIR) sensor array with neural network technology (NNT) processing, FL4000 protects people, equipment, and facilities from dangerous hydrocarbon flame sources within 230 ft range. Intelligent system discriminates between actual flames and nuisance false alarm sources using 4 separate IR spectrums which sample different IR spectral areas. Flame or non-flame decision is output via LEDs, relays, and MODBUS.
|
 Flame Detectors monitor for hydrocarbon-based fires.Mine Safety Appliances Company / Instrument Division
Pittsburgh, PA 15230
Dec 06, 2005
Designed to detect UV and/or IR radiation emitted by hydrocarbon-based fires and flames, FlameGard Detectors operate as stand-alone units or can be connected to fire or security system. They are enclosed in copper-free, explosion-proof aluminum housings and can be mounted with bracket or optional swivel mount kit. In dusty environments, optional air purge kit keeps viewing glass clear. Detectors are FM approved and include false alarm suppression.
|
 Flame Detectors provide high false alarm immunity.General Monitors
Lake Forest, CA 92630
Jul 29, 2005 Microcontroller-based, ATEX-approved UV/IR Model FL3110 and UV Model FL3111 include flicker-discrimination circuitry and self-checking continuous optical path monitoring to ensure fire protection. Both feature segregated wiring compartment where field terminations can be made without exposing ex-proof section to elements. Electronics are integral within stainless steel explosion-proof housing, allowing information to be processed at point of detection. |
 Communications Protocol offers accurate event reporting.Gamewell Co., The
Ashland, MA 01721
Mar 21, 2005 SmartScan is offered on company's IdentiFlex 600 Series fire control panels. It provides alarm verification per detector and is fully digital. Panel end-to-end response is reduced to less than 5 sec, and 198 devices per loop can be supported. Protocol enables loop distances up to 12,000 ft of twisted pair, parallel pair, THHN, and shielded wire types. One loop poll covers 10 devices. |
 Flame Scanner detects presence and condition of flames.Hamworthy Peabody Combustion Inc.
Shelton, CT 06484
Nov 03, 2004 SmartScanâ„¢ 121 microprocessor flame scanner senses presence and condition of flames in various applications. Suited for coal, oil, gas, and non-standard fuel scanning, it features bar graph display, -40º to +140ºF operating temperature, and discrimination techniques. Pilot and ignition systems, available in oil-electric, gas-electric, and direct-spark, offer capacities up to 30 MM BTU/h standards and operate under all furnace and combustion air conditions. |
 Flame Detector monitors for hydrocarbon-based fires.MSA
Pittsburgh, PA 15230 0426
Oct 14, 2004 FlameGard® UV/IR Flame Detector detects UV and IR radiation emitted by hydrocarbon-fueled fires and responds by activating relay, which can be part of fire alarm loop or connected to digital control system. Enclosed in heavy duty, copper-free, explosionproof aluminum housing, unit provides stand-alone operation or can be connected to standard 4-wire fire control panels. Optional Air Purge Kit keeps viewing glass clear in dusty environments.
|
 Pyroelectric Detectors produce low noise.Electro Optical Components
Santa Rosa, CA 95403
Aug 02, 2004 Series LMM low microphonic detectors exhibit 20x reduction of detector noise output caused by mechanical vibration. High Gain pyroelectric detectors have responsivity up to 100x over standard detectors without increase in noise. Units are suited for heat and flame detection and gas analysis in applications such as medical, refinery, mining, automotive, and semiconductor instrumentation. |
 Evacuation System delivers high-wattage amplification.Fire Control Instruments, Inc.
Waltham, MA 02451 1122
Jun 17, 2004 NetSOLO® CLASSIC enables fire detection; emergency, multi-channel voice evacuation; 2-way fire fighter communications; and building control applications. Assembled from 7100 NetSOLO and INCC-C Command Center nodes, product is capable of multiple sequences of operations and uses Field Configuration Program based on Boolean logic statements. Unit includes Ethernet Interface Module, and timing functions can be attached to I/O logic statements. |
 Fire Detection System offers optional 6 in. VGA display.Siemens Building Technologies Inc.
Florham Park, NJ 07932
Jan 06, 2004 System MXL utilizes Model MMB-3 processor board to help bring systems into compliance with NFPA and UL requirements. Board includes 2 analog loop device circuits allowing use of unshielded, untwisted wires. It employs firmware in flash memory so code added to laptop computer can be downloaded directly into powered panel. Board allows up to 50 loops and FirePrint detectors on MXL system. Optional MKB-5 display is backlit and shows 8 system events simultaneously. |
 Optical Flame Sensor eliminates false turbine trips.AMETEK, Power & Industrial Products
Wilmington, MA 01887
Dec 23, 2002 Spectraâ„¢ GT30 solid-state sensor receives UV energy from combustion process and transmits 4-20 mA analog signal proportional to flame intensity. It operates continuously at 257°F without cooling. Able to withstand combustion pressures up to 30 Bar, 2-wire, 24 Vdc loop-powered sensor is self-contained. Hermetically sealed, stainless steel sensor includes dual gain amplifier with saturation limiting circuitry. |
 Gas/Fire Monitor offers 4-way versatility.Crowcon Detection Instruments
Milford, OH 45150
Dec 05, 2002 Standard wall-mounted Vortex multi-channel system provides up to 12 gas detection channels, including up to 3 for fire, plus 24 user configurable relay outputs to drive external alarms and safety equipment. Modular version comprises input, output, and controller modules mounted on Modbus data transfer rail. Vortex Rack combines essential modules with 19 in. rack fascia, featuring button controls and status indicators. Vortex Panel flush mounts in door or panel in non-rack enclosures. |