ThomasNet News Logo
Sign Up | Log In | ThomasNet Home | Promote Your Business
 Journals
Industry Market Trends ®
IMT Career Journal
IMT Fluid & Gas Flow Journal
IMT Green & Clean Journal
IMT Machining Journal
IMT Procurement Journal
 Industry News
Latest New Product News
Association & Government News
 Product News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Green & Clean
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
FABTECH
Society of Manufacturing Engineers
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP
Sensors Monitors & Transducers -> Monitors


Monitors





(Showing headlines 201 - 220)   << 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 ...
Waste Compactor Monitor detects hydraulic fluid leaks.

Waste Compactor Monitor detects hydraulic fluid leaks.

One Plus Corporation    Northbrook, IL 60062
Oct 18, 2011 Combined with Wireless Waste Edge® Monitor, Leak Edge® option protects compactor users with fail-safe, automated real-time hydraulic fluid leak detection and sends remote alerts by text/email. System utilizes submersible level-sensing probe to identify hydraulic leaks of less than 6 oz, shuts down compactor to stop active leak, and auto-restarts when fluid level is restored. Monitors automatically send fullness, pick-up notifications, and Leak Edge alerts to hauler or other designated recipient.

PV Monitoring System can monitor individual PV strings.

Teal Electronics Corporation    San Diego, CA 92121
Oct 17, 2011 PVobserver(TM) string monitoring and wireless communication option, available for Configurable Combiner Box, lets operator of commercial or utility scale Solar PV power plant know immediately if individual PV string is underperforming or needs maintenance. SunSpec-Compliant, embedded unit monitors current of each PV module string as well as string voltage and communicates processed data to internet via standard communications protocols and connections.

Diesel Fuel Filter Monitor meets marine industry needs.

Skimoil, Inc.    Carrboro, NC 27510
Oct 14, 2011 Especially valuable for vessels that do not have constant filter monitoring, diesel FUEL FILTER ALERT and alarm system provides real-time indication of fuel filter status. Vacuum instrument detects fuel-filter degradation and alerts operators so they can take action before failure. System consists of stainless steel sensors and remote digital display panel with numeric pressure readout, active messages, and graduating, colored-light indicator.

Capnograph targets mice and other small rodents.

Harvard Apparatus, Inc.    Holliston, MA 01746 1371
Oct 14, 2011 Providing continuous measurement of end-tidal CO2 through infrared spectroscopy sensor, Type 340 Capnograph is suitable for breathing ranges from 0-300 bpm. Data is displayed in real time; and with analog ports, data can be collected simultaneously with most commercial data acquisition systems. Optional flow heads expand Capnograph to measure Peak Inspiratory and Expiratory Flow, Peak Inspiratory Pressure, Positive End Expiratory Pressure, and Tidal Volume.

Air Quality Tester features portable, multifunctional design.

Air Quality Tester features portable, multifunctional design.

E Instruments International LLC    Langhorne, PA 19047
Oct 12, 2011 Featuring ABS shockproof housing with IP54 rating for dust protection, Model AQ200 measures CO2 from 0-5,000 ppm, CO from 0-1,000 ppm, and ambient temperature from -4 to 176°F as well as Delta T, atmospheric air pressure, and humidity. IAQ monitor includes Ice Blue LCD with 2-line display, Min/Max/Hold/Unit selection, and 8,000 data memory points. Memory and software are provided.

Single-Leg Hazard Monitor enhances predictive maintenance.

Single-Leg Hazard Monitor enhances predictive maintenance.

Electro-Sensors, Inc.    Minnetonka, MN 55343 9108
Oct 05, 2011 Employed to protect against breakdowns and machinery failure, Electro-Sentry 1 is commonly used on grain elevator legs to monitor critical points for shaft slowdown, belt alignment, and bearing temperature. Single-leg, stand-alone system delivers at-a-glance alarm identification, 13 analog inputs, 8 relay outputs, and one-button test capabilities. All components provide 4-20 mA signal compatible with IS Barriers, PLCs, meters, and DAQ systems.

CO/Nitrogen Dioxide Transmitters support in-field calibration.

CO/Nitrogen Dioxide Transmitters support in-field calibration.

Dwyer Instruments, Inc.    Michigan City, IN 46361
Sep 19, 2011 Used to monitor gas concentration in underground parking garages and loading docks, Series GSTA offers field-selectable current and voltage outputs that allow transmitters to be used with almost any building management controller. User can select output range to be 0-200 or 0-500 ppm for carbon monoxide (CO) units, and nitrogen dioxide units come with 0-10 ppm range. Using internal dip switches, output can be inverted to read 20-24 mA or 10 (5) to 0 Vdc.

Dissolved Gas Analyzer offers online condition monitoring.

Doble Engineering Company    Watertown, MA 02472
Sep 16, 2011 Designed for continuous monitoring of dissolved gas in oil, Doble Delphi delivers critical information in real-time, providing power transformer substation engineers with intelligent alerts and trend analysis for asset management. Device is available as hydrogen monitor or composite gas monitor and can be mounted directly to transformer valve. Using fuel cell technology and optional micro-pump circulation, instrument provides accurate measurements with alarms that appear on display and software.

Chassis Monitoring Board aids efficient VME/VPX system management.

Chassis Monitoring Board aids efficient VME/VPX system management.

Kontron    Poway, CA 92064
Sep 14, 2011 Suitable for VPX and VME systems, Kontron CMB (chassis monitoring board) streamlines system monitoring and management of rugged applications. It centralizes out-of-band monitoring and management of installed boards and system parameters, such as temperature, airflow, and power supply, in critical COTS systems. Designed for multi-board and multi-vendor environments, product is based on common interface technology, such as I²C and GPIO, and requires less than 1 W.

Automatic Spectroscopic Ellipsometer operates at high speeds.

Ulvac Technologies, Inc.    Methuen, MA 01844
Sep 12, 2011 Equipped with automatic R-Theta stage, UNECS-3000A measures thickness and refractive index of transparent or semi-transparent thin film. Automatic mapping function can handle 300 mm dia wafer substrates, and non-contact instrument can measure 106 points on 300 mm dia wafer within 120 sec. Max measurement speed is 20 ms/point, and other features include automatic height adjustment, editable materials table file, and ability to concurrently analyze up to 6 layers of film thickness.

Transformer Monitoring System suits large-scale applications.

Acorn Energy, Inc.    Montchanin, DE 19710
Sep 09, 2011 Addressing needs of large-scale pole top applications at distribution level, TransformerIQ® is installed without shutting off power, is environmentally sealed, and uses battery-less technology, which makes it essentially maintenance-free. Complete solution includes integrated radio/sensor package, secure communications, GUI, text/email messaging, and interface to utility operations, enabling new applications and smart grid objectives.

Mobile Gas Monitoring Device uses wireless technology.

Mobile Gas Monitoring Device uses wireless technology.

Safety Supply South LLC    Irmo, SC 29063
Aug 22, 2011 Developed for use at industrial sites, Dräger X-zone 5000 is used in conjunction with Dräger X-am 5000 personal gas detection device to create wireless fence line alarm for toxic gases. Transportable device can be used individually or as part of continuous wireless network with up to 25 units for monitoring large areas, such as pipelines and storage tanks. Each unit continuously monitors up to 6 explosive, flammable, or toxic gases, and warns if one of them is present in ambient air.

Energy Monitoring System delivers data via web browser.

E-Mon Corp.    Langhorne, PA 19047
Aug 02, 2011 Suited for campus and multi-building facility applications, Web-Mon(TM) Enterprise Edition provides one-page dashboards of historical and real-time energy use via standard web browser over Modbus IP LAN/WAN networks using Modbus TCP/IP as communication protocol. System displays electrical consumption, peak demand, power factor, Volts, Amps by phase, and VARs. Internal memory stores up to 36 days of 15-min interval data, and user alerts are emailed when kW/kWh usage alarm setpoints are exceeded.

Building Monitoring System provides structural health data.

Building Monitoring System provides structural health data.

Digitexx Data Systems, Inc    Pasadena, CA 91101
Jul 22, 2011 When event occurs and sensor thresholds are exceeded, REFLEXX Smart System for Buildings combines real-time data with structural algorithms to rapidly provide detailed, actionable damage probability report. System enables engineer to understand key building parameters such as accelerations, displacements, velocities, and interstory drift ratios. Within 15 minutes of event, REFLEXX sends detailed report describing structural health of building at global, floor-by-floor, and component level.

Critical Condition Monitoring System offers remote data collection.

Winland Electronics, Inc.    Mankato, MN 56001
Jul 22, 2011 Featuring Ethernet connectivity, EnviroAlert EA800-ip provides 2-way access to remotely monitor and collect data on up to 8 sensors for changes in temperature, humidity, water, gases, pressure, and dry contacts. Sensor settings may also be modified via network connection, and email and text message support is provided for trend and alarm notification. Able to monitor multiple sites from any location, system provides complete audit trail and is compliant with 21 CFR Part 11.

Remote Monitoring System is designed for cabinets and small sites.

Remote Monitoring System is designed for cabinets and small sites.

Quest Controls, Inc.    Palmetto, FL 34221-4802
Jul 21, 2011 Designed to eliminate downtime by acting as early warning system, TELSEC MINI(TM) PLUS provides alarm monitoring in cabinets, OTNs, shelters, small remote sites, and computer centers. Unit is powered from 24-48 Vdc and can monitor up to 6 universal inputs, including temperature, humidity, commercial power fail, DC Plant alarms, HVAC failures, fire/smoke, and intrusion. Featuring embedded Web Server, TELSEC MINI PLUS provides SNMP traps and informs over Ethernet back to alarm center.

Weld Purge Monitor has integrated pump for extracting gas sample.

Weld Purge Monitor has integrated pump for extracting gas sample.

Huntingdon Fusion Techniques-USA Inc.    Melbourne, FL 32936-1175
Jul 11, 2011 Utilizing non-chemical sensor technology, PurgEye(TM) 500 measures oxygen levels down to 10 ppm. Alarm facility can be set to activate if oxygen levels around weld exceed desired value and in association with alarm, can shut welding machines off and on again as gas levels raise and lower. With PurgeLog(TM) software, operators can store and print data for quality control purposes so that each weld can be supported with relevant document showing weld purge integrity.

Handheld Radiation Meter enhances safety via sensitivity.

Industrial Test Systems, Inc.    Rock Hill, SC 29730
Jul 11, 2011 Suited for detecting environmental/industrial contamination, DX-2b detects gamma, beta, and X-rays. Its military-grade GM tube detects all gamma and beta isotopes released by nuclear power plants, such as iodide and cesium. Offering one-button operation to facilitate use by nontechnical persons, meter uses 200 Vdc, Geiger Müller tube detector and provides visual and audible warnings. This 3¼ x 6¾ x 1½ in. unit is powered by 9 V battery, which lasts 50 hr at normal background levels.

Telemetry System supports irrigation applications.

Telemetry System supports irrigation applications.

McCrometer, Inc.    Hemet, CA 92545
Jul 08, 2011 Providing wireless data collection, RemoteCONNECT(TM) RC45 delivers information via Internet from installed flow meters, pumps, and other agricultural water management sensors operating remotely in field. Web-based GUI notifies operators of any changes in irrigation system or other sensors via Internet, email, mobile phone, texting, or pager. Equipped with 2 digital inputs, 2 analog inputs, and 1 analog output, mast-mounted system offers choice of 300 mA solar or 110 Vac power supply.

Photometer measures free chlorine and chlorine dioxide.

Photometer measures free chlorine and chlorine dioxide.

Sensorex    Garden Grove, CA 92841
Jul 06, 2011 Supporting FCL400 Free Chlorine Sensor and CLD400 Chlorine Dioxide Sensor, FCLA 7000 eXact Photometer utilizes 525 nm LED light source to measure free chlorine from 0-11 ppm or chlorine dioxide at 0-6.5 ppm with photometric precision of ±0.1/0.01% T and transmission range of 100-0.00% T. EPA-compliant, battery-powered unit operates from 32-122°F and features 3-digit customized LCD with annunciators, automatically displaying 0.01 or 0.1 resolution.




(Showing headlines 201 - 220)   1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79


Home  |  My ThomasNet News®  |  Industry Market Trends®  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2013 Thomas Publishing Company. All Rights Reserved.
Terms of Use - Privacy Policy