Sensors, Monitors & Transducers
(Showing headlines 6781 - 6800) << 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 ...
|
 Pressure Sensor has two outputs.Sensotec, Inc.
Columbus, OH 43228
Jun 07, 2002 Model DS pressure sensor provides RS485 or RS232 output capable of 380 readings/second and 0 to 5 Vdc analog output with frequency response rated to 1200 Hz. All-welded stainless steel construction is suited for factory floor or test cell installation. Model DS has combined accuracy of ±0.1% FS, including temperature errors over compensated temperature range. Pressure ranges are available from 0 to 5 psi up to 0 to 10,000 psi. |
 Corrosion Monitoring System listens for damaging noise.USFilter's Stranco Products
Bradley, IL 60915 0389
Jun 07, 2002
CoolSIM(TM) on-line cooling water management tool measures electrochemical noise that takes place with transfer of electrons that create corrosion. This allows facilities to monitor system corrosion, pitting, and fouling in real time, under actual flow and heat transfer conditions, and therefore optimize chemical treatment programs. It recognizes when corrosion and pitting begin to occur in heat exchanger, and when corrosion and pitting activity stop.
|
 X-Ray Analyzer measures microstructures.Fischer Technology Inc.
Windsor, CT 06095
Jun 07, 2002 Fischerscope® X-Ray XDVM®-u uses X-ray fluorescence and micro-focus X-ray optics to measure and analyze microstructure coatings on structures as narrow as tens of microns. It can analyze thickness and composition of multiple coatings containing up to 24 individual elements, either in pure element or alloy coatings. Applications include testing and measuring miniaturized electronics, including PC boards, chips, and contacts.
|
 Torque Sensors measure in both directions.Lebow Products, Inc.
Troy, MI 48084-4600
Jun 07, 2002 Model 2133 Series measures static torque in clockwise or counterclockwise directions. Models cover torque ranges from 10 to 1000 lb-ft in 7 different rated capacities, with Ľ to 1 in square drive size configurations. Each unit is temperature compensated from 70 to 170°F over useable temperature range from -65 to +200°F. Accuracy is ±0.25% of rated output with sensitivity output of 2 mV/V nominal. All sensors are calibrated with standards traceable to NIST.
|
 Emissions Analyzer is powered by rechargeable battery.Crowcon Detection Instruments Ltd.
Erlanger, KY 41018
Jun 07, 2002
Tempest 100 handheld analyzer monitors gaseous emissions, calculates combustion efficiency, and logs and prints gas data. Detectable gases include CO, CO2, nitrogen monoxide, and O2. All data can be downloaded to PC. Tempest 100 also provides unattended monitoring over extended periods via programmable datalogging. It analyzes combustion performance with integral thermocouples, which measure inlet, stack, and ambient temperature.
|
 Vibration Meters suit machinery condition monitoring.PCB Piezotronics Inc.
Depew, NY 14043 2495
Jun 06, 2002 Up to eight Model 683 Vibration Meters can be housed in NEMA4X-rated, fiberglass, Series 684 Enclosures. Vibration meters offer excitation power for 4 to 20 mA vibration sensors or ICP® accelerometers. They display peak or rms vibration data on fully scalable LED display. Set point relays (two) offer alarm or control capabilities, and relay action is time-delayed. Hinged doors provide access to necessary wiring. |
 Pressure Sensors detect high intensity acoustics.PCB Piezotronics Inc.
Depew, NY 14043 2495
Jun 06, 2002 Series 106 and 116 can measure low-level pressure and high-intensity acoustic and ultrasonic sound pressure levels. Both have solid-state construction, no moving parts, stainless steel housings, high frequency range, and up to 500 mV/psi sensitivity. Applications include monitoring pulsations, turbulence, and noise in hydraulic and pneumatic systems; detecting pressure fluctuations in compressors, turbines, pumps and pipe lines; and measuring noise of jet engines.
|
Voltage Monitor has wide input range.Time Mark Corp.
Tulsa, OK 74116 2019
Jun 06, 2002 Model 2629 monitors over and under ac or dc voltage, and has input range from 15 to 260 V. It has adjustable trip points, automatic reset, and DPDT relay. Dead band is less than 5% between pull-in and drop-out. |
 Safety Switches prevent access.Banner Engineering Corp.
Minneapolis, MN 55441
Jun 05, 2002
Hinge-style Safety Interlock Switches are integrated and encapsulated into load-bearing hinge to provide protection from tampering. Components are concealed inside hinge to prevent access and provide protection from mechanical impact and washdown. Applications include hinged machine covers, doors, gates, and safety fencing systems. Switches have IEC IP67 rating, IEC 60947-5-1 positive-opening safety contacts, and can support axial load of 165 ft-lb.
|
 Background Suppression Sensor offers long sensing ranges.ifm efector, Inc.
Exton, PA 19341
Jun 05, 2002
OJ Series Photoelectric Sensor ignores shiny metal or bright white backgrounds typically found in conveyor applications. It senses small targets at distances up to 400 mm. Visible red light source provides precise target detection and highly visible 18 mm dia light spot. Sensor offers front or side sensing and includes quick disconnect feature. Microprocessor-based pushbutton adjustment simplifies installation and setup.
|
 Oxygen Monitor utilizes electrochemical sensor.Delta F Corp.
Woburn, MA 01801 1087
Jun 04, 2002
Series 500 microprocessor-based, ambient air oxygen monitor incorporates non-depleting sensor which is factory calibrated to NIST Traceable Standards and lasts life of monitor. Sensor eliminates false alarms due to sensor depletion. Monitor includes built-in battery back-up, dual adjustable oxygen alarm setpoints, 0-25% range, and 1/2 in. LCD. Sentry Circuit(TM) monitors instrument calibration against any system or condition changes.
|
 Position Transducers use Indres(R) inductive technology.Novotechnik U.S., Inc.
Southborough, MA 01772
Jun 04, 2002 TLC Series supports measuring lengths from 100 to 1000 mm. Output voltage is proportional to position of probe moving near, but not touching, 2 resistive tracks that are inductively coupled. Integrated ASIC provides linearization and filtering for resolution better than 0.01 mm. Rodless design, with ball coupling, accommodates side loads. Sensors operate at speeds to 10 msec with repeatability less than or equal to 0.01 mm. |
 Sensor offers rugged front-face material.TURCK, Inc.
Plymouth, MN 55441
Jun 04, 2002
WeldGuard Sensor is available in AC/DC ferrite core with WFI, DC U-prox®, and extended ferrite core with 2- and 3-wire DC. Front face material lasts 13 times longer than standard sensor face materials. Barrel is either stainless steel or Teflon® coated. Sensor comes in 8, 12, 18, and 30 mm barrel sizes and cube style CA40 (40 mm cube). It is suitable for resistance welding in automotive applications.
|
 Linear Sensor Arrays operate at 5 MHz clock.TAOS Inc.
Plano, TX 75074
May 31, 2002
Model TSL2014, 896 x l Linear Sensor Array measures 4.4 in. in length and is designed for scanning A6 format-size documents. It comes in 10-pin Glass Epoxy Substrate package with Cover Glass. Model TSL210, 640 x 1 Linear Sensor Array measures 3.15 in. in length, and comes in 18-pin Glass Epoxy Substrate package with Cover Glass. TSL210 can be configured in serial mode. TSL2014 can be configured to run in serial or parallel mode.
|
 Force Tranducer is shock and vibration qualified.Strainsert Co.
West Conshohocken, PA 19428 2793
May 31, 2002 Force Transducer is available with internally gaged, force sensing clevis pins and instrumentation packages in shock-qualified configurations to MIL-901D specifications. Similar clevis pin designs, incorporating internal 4-20 mA amplifiers, have also been qualified for specific vibration environments. Internal gaging is environmentally protected. |
 Encoders offer various output options.Encoder Products Co.
Sandpoint, ID 83864
May 30, 2002 Model 775 and 776 Slim Line Thru-Bore Encoders are available with protective cover that increases sealing capabilities. Model 775 and 776 measure .840 and 1.36 in. thick and offers bore sizes to 1.375 and 1.875 in., respectively. Both feature noise and electrostatic discharge immunity. Rated to 100°C, they provide resolutions to 4,096 CPR, and are available with phenolic inserts for electrical and thermal isolation. |
 Screw Micrometers measure materials up to 1.000 in. thick.GEI International, Inc.
Syracuse, NY 13217 6849
May 29, 2002 BNS Series measures thickness of sheet metal, card, paper, and other materials in 0.001 in. increments. Thickness on some models is displayed on digital readout. All units incorporate ratchet to prevent compressing soft materials when measurements are taken. Inch and metric versions are available. All models are supplied in plastic or wood storage cases. |
 Liquid Level Sensor features brass housing.Gentech International
Rochester Hills, MI 48307
May 29, 2002 VS703-51 utilizes Buna N float, and features normally open or normally closed designs. Mounted vertically, it can be fitted internally or externally via compression grommet system, either via top or bottom entry of tank. Maximum switch ratings are 100 Vdc and 250 Vac, and operating temperature range is -30 to 130°C. Sensor is suitable for high or low switch point level sensing. |
 Force Test Stands are controlled by PCs.Dillon, A Div. Of Weigh-Tronix
Fairmont, MN 56031
May 29, 2002 Tabletop TC˛-i and SnapShot-i provide compression, tension, and flexure testing capabilities up to 550 and 220 lbf, respectively. Both use intelligent load cells that send test data directly to PC via serial port with speed of 2,000 samples/sec. User-friendly i-software controls test stand and compiles data. Analytical capabilities include graphing, data interrogation, and exporting. Both are programmable for crosshead travel speed from 0.039 to 19.7 ipm. |
 Level Transmitter provides accurate liquid measurement.Flowline Inc.
Los Alamitos, CA 90720
May 29, 2002 Ultrasonic LA12 Cricket™ 2-wire transmitter mounts through top wall of tank and provides continuous liquid measurement from 0.3 to 10 ft. It has automatic temperature compensation over entire range, NEMA 4X IP65 enclosure with ˝ in. conduit connector, 4-20 mA output, and LED power-status indicator. Acoustic wave guide, available in PP, PVC or PVDF, reduces measurement space to ˝ in. while separating foam from point of measurement. Accuracy is ±1% of span. |
(Showing headlines 6781 - 6800) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362
|
|
|