Sensors, Monitors & Transducers
(Showing headlines 5781 - 5800) << 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 ...
|
 Vibration Switch provides predictive maintenance.PCB Piezotronics Inc.
Depew, NY 14043 2495
Jan 23, 2004 Model 685A01 is a 24 Vdc powered, electronic vibration switch with explosion-proof housing. It provides early warning of machine deterioration and will shut machine down when trip level is exceeded. Unit includes Form C relay, adjustable trip point, local and remote reset, and continuous or latch relay operation. Operating range is 0–10 g's from 10–1,000 Hz, making it suited for pumps, fans, blowers, compressors, and gearboxes. |
 Magnetic Rotary Encoders offer rugged design.Renishaw, Inc.
Hoffman Estates, IL 60192
Jan 22, 2004
Non-contact RM series consists of 10, 11, and 12-bit miniature magnetic rotary encoders that deliver positioning with 4,096 count resolution to over 9,000 rpm with accuracy to 0.4°. Designed for integration, they include component, modular, and packaged shaft-style models. Outputs include absolute versions with parallel or serial data formats, as well as versions with incremental, analog, linear voltage and linear current outputs.
|
 Safety Valves have compact design.Spence Engineering Co., Inc.
Walden, NY 12586-0230
Jan 21, 2004 Figure 50 Series bronze and aluminum body safety relief valves provide overpressure protection of pneumatic conveyor systems, trailers, and storage vessels containing powdered solids that are loaded or unloaded by compressed air. Available in 2 in. female NPT screwed connection sizes with set pressures to 30 psig at 225°F, valves feature tamper-proof spring setting, weather-proofed construction, and diaphragm seal with multiple vent design. |
 Capacitive Sensors eliminate need for potentiometer.Carlo GAVAZZI Automation Components
Buffalo Grove, IL 60089
Jan 20, 2004 Microprocessor-based TRIPLESHIELDâ„¢ Capacitive Sensors feature single push-button Teach-Mode that allows user to program sensing range and output. They can be fully programmed remotely using remote teach wire. Sensing range is 12 mm for M18 and 30 mm for M30 style. Sensors automatically detect load type and adjust to NPN or PNP, and flush or non-flush mounting. They are protected against ESD, wire-conducted noise, airborne RF, and transient voltages. |
 Personal Gas Detectors suit safety and fire service workers.Biosystems Div., Bacou USA Safety Inc.
Middletown, CT 06457
Jan 20, 2004 Able to detect O2, H2S, CO, and other toxic gases, ToxiPROâ„¢ reusable, single-sensor gas detectors provide real-time, peak, STEL, and TWA readings. They feature replaceable battery and sensor, one-button automatic calibration, and direct-reading backlit display. Units also have 20-incident event logger and black box recorder. Visual and audible signals are provided for Warning, Danger, STEL, and TWA alarms; internal vibrating alarm is optional. |
 Test Cabinet offers temperature range of -30 to +90°C.Atlas Material Testing Technology LLC
Chicago, IL 60613 1831
Jan 20, 2004 Model CCX Advanced Cyclic Corrosion Cabinet with 90°C option features temperature-resistant materials for dispersion towers and connectors, temperature-resistant fiberglass shell and gel coat, fiberglass cover with tempered-glass viewing window, and insulation around exposure zone. Unit replicates stresses that result in degradation including salt-saturated air and salt spray, high humidity, condensation, sunlight, and temperature variations. |
Monitors gather power and energy information.Rockwell Automation
Milwaukee, WI 53204
Jan 20, 2004
MiniPowermonitors(TM) communicate power and energy data to central control system or programmable controller for analysis and energy optimization. MiniP M610 digital 3-phase AC monitor cyclically displays line-neutral and line-line voltages on 3 phases simultaneously. MiniP M620 continuously measures power and energy parameters of 3-phase power lines. When over- or under-voltage conditions occur, it trips alarm relay and displays code character to identify cause.
|
 Disposable Gas Detectors offer 24-month service life.Biosystems Div., Bacou USA Safety Inc.
Middletown, CT 06457
Jan 19, 2004 ToxiLTDâ„¢ Gas Detectors monitor for CO, H2S, or O2, depending on sensor installed, and alert workers to presence of gases using visual and audible alarms. Units are equipped with 20-incident event logger and black box recorder. Enclosed in ABS case with over-molded rubber boot, detectors are resistant to RFI, have UL and cUL intrinsic safety certifications, and are classified for Hazardous Locations Class I, Division 1, Groups A-D. |
 Ferromagnetic Sensor provides vehicle detection.Banner Engineering Corp.
Minneapolis, MN 55441
Jan 16, 2004
Utilizing magnetoresistive-based passive sensing technology, M-GAGE® S18M detects 3-dimensional changes in Earth's magnetic field when presence of large metal objects such as car, truck, or railcar is introduced, causing sensor's output to switch. Unlike inductive loop technologies, self-contained sensor functions as receiver and has no external controller. Program commands can be entered through pushbutton on sensor or via portable programming box when sensor is inaccessible.
|
 Fire Detectors offer application-specific technology.Faraday, LLC
Tecumseh, MI 49286
Jan 15, 2004 Suited for small- to medium-size installations, FireSmartâ„¢ Application Specific Detectors employ software algorithms and neural network to sense smoke and heat. To eliminate false alarms, detectors are adjustable for optimum response in 11 environments, such as healthcare facilities, office/retail environment, dormitory or hotel room, HVAC duct, and warehouses. Units ignore cigarette smoke, dust, and car exhaust and offer early warning to true threat of fire. |
 Fiber-Optic Laser Encoder enables multi-axis positioning.Renishaw, Inc.
Hoffman Estates, IL 60192
Jan 15, 2004
Model RLE10 delivers interferometer-based, nanometer positioning accuracy to multiple axes from single remote laser source. Available in configurations for linear or planar applications, system can be applied to axis lengths up to 4 m. Encoder can provide either 2 different selectable-resolution, RS422-format, digital quadrature outputs, or both analog 1 Vpp sin/cos signals and digital output quadrature output simultaneously.
|
 Differential Pressure Gauge suits seawater applications.Mid-West Instrument
Sterling Heights, MI 48314
Jan 15, 2004 Model 120 Series Filter Minder ranges from 0–5 through 0–100 psid with accuracy of ±5% FS ascending. Differential pressure is sensed by movement of floating piston magnet against calibrated spring. Gauge pointer, outside pressure housing, follows movement of piston magnet and indicates pressure. Made of aluminum bronze or monel, unit is weather-resistant and offers working pressure of 5,000 psig. Dial is 2½, 3½, or 4½ in. round with shatter-resistant lens. |
 Enabling Switch Device aids in set-up of robotic machinery.Scientific Technologies Inc.
Fremont, CA 94555
Jan 14, 2004 CE listed to all applicable standards, ESD5020 provides margin of safety needed during troubleshooting, set-up, programming, or servicing of robotic or automated machinery. Dual 3-position enabling switches are integrated into trigger to provide operator with constant control. Trigger has recognizable, middle enabled position, while redundant switch contacts ensure that machinery can be stopped by releasing or squeezing trigger. |
 Thermocouple employs smart sensor technology.Watlow
St. Louis, MO 63146
Jan 14, 2004 Made of alloy 600 and nickel-silicon, WATCOUPLE is based on IEEE 1451.4 smart sensor technology, which enables unit to communicate individual voltage table, calibration, manufacturing, and traceability information. WATCOUPLE is available in all standard sizes and configurations. Applications include power generation, chemicals, mining and glass processing, semiconductor, and test stands. |
 Test Systems measure water vapor and O2 transmission rates.Mocon
Minneapolis, MN 55428
Jan 14, 2004
OX-TRAN® Model 702 and PERMATRAN-W® Model 700 feature COULOX® coulometric-type sensor for measuring oxygen and modulated infrared sensor for measuring water vapor. Seven-cell configuration allows 7 different structures to be tested independently. Pushbutton-actuated, pneumatic clamping device facilitates loading of material into cell and provides consistent pressure. Systems are suited for packaging applications where product is subjected to degradation by oxygen or moisture.
|
 Integrated Flow Transmitter performs 5 functions.E Instruments International LLC
Langhorne, PA 19047
Jan 12, 2004
Model PT 2 tube and flow computer transmitter reports velocity, process gas temperature to 1200ºF, volumetric and mass flow, and differential pressure. Transmitter head includes 0-5 in. wg differential pressure transducer, 15 psi absolute pressure transducer, and thermocouple amplifier with cold junction compensation. Additional features include 4-20 mA analog outputs, programmable alarms, and RS 232 PC software for data logging and display.
|
 Flow Monitor/Data Logger measures multiple characteristics.E Instruments International LLC
Langhorne, PA 19047
Jan 08, 2004
Hand-held PT 3 portable flow monitor includes integrated probe with Pitot, Temperature, Static Pressure, and Log Trigger. Auto Log Trigger allows measurements and calculated parameters to be made and stored for analysis with provided software and transferred to PC program such as Word or Excel. Unit measures velocity; temperature to 1,475ºF; turbulence; flow mapping; and differential, barometric, and absolute pressure. It also calculates volumetric and mass flow.
|
 Safety Interlock Switch meets category 3 safety requirements.Scientific Technologies Inc.
Fremont, CA 94555
Jan 07, 2004 MC-S Series compact coded magnetic safety interlock switch consists of tamper-resistant, non-contact switch that operates with control unit that provides motor contactor monitoring and/or manual reset function. Switch and control unit act as fully monitored, dual channel system. Series is available in 3 sizes with plastic or stainless steel NEMA 6 enclosure suited to harsh environments. Single control unit monitors and indicates up to 6 MC-S switches. |
 Accelerometer offers measuring range of ±500 g.Kistler Instrument Corp.
Amherst, NY 14228 2119
Jan 06, 2004 Cube-shaped, IEPE triaxial accelerometer, Model 8763A500 permits simultaneous shock and vibration measurements in 3 mutually perpendicular axes. Three 5–40 threaded holes allow stud mounting on test object, utilizing each side of cube. Shear element technology assures immunity to base strain and thermal transients. Miniature 4-pin ceramic insulated connector provides stability over operating temperature, and welded titanium provides hermetic isolation. |
 Fire Detection System offers optional 6 in. VGA display.Siemens Industry, Inc., Building Technologies Division
Florham Park, NJ 07932
Jan 06, 2004
System MXL utilizes Model MMB-3 processor board to help bring systems into compliance with NFPA and UL requirements. Board includes 2 analog loop device circuits allowing use of unshielded, untwisted wires. It employs firmware in flash memory so code added to laptop computer can be downloaded directly into powered panel. Board allows up to 50 loops and FirePrint detectors on MXL system. Optional MKB-5 display is backlit and shows 8 system events simultaneously.
|
(Showing headlines 5781 - 5800) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362
|
|
|