Sensors, Monitors & Transducers
(Showing headlines 401 - 420) << 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 ...
|
 Magnetic Tape Encoders mount directly, repeatedly to shafts.Baumer Ltd.
Southington, CT 06489 1534
Aug 18, 2011
Used for speed and position monitoring, HDMag series is comprised of bearing-less and contact-free encoders that attach to drive or generator shaft via customized, flexible magnetic tape. Products can be installed and removed repeatedly without affecting performance, and read-head incorporates dual sensor head mounted to frame over flexible tape. This operates without interruption over fastening gap in tape ends and has no effect on encoder output signal.
|
 Guided Wave Radar Transmitter is intended for use with solids.Dwyer Instruments, Inc.
Michigan City, IN 46361
Aug 17, 2011
Available with rigid or flexible probe, Series GWB provides analog and switching output (4-20 mA as well as NC SPST switch output) to provide continuous level indication of powder bulk material. It can output level indication as continuous measurement reading through its analog output or alter that information into freely adjustable switching output signals. Time Domain Reflectometry promotes accuracy and stability as well as suppression of disturbance signals.
|
 Guided Wave Radar Transmitter offers analog or switch output.Dwyer Instruments, Inc.
Michigan City, IN 46361
Aug 17, 2011
Available with rigid or flexible probe, Series GWL delivers 4-20 mA analog or NC SPST switch output, providing continuous level indication of liquids. Time Domain Reflectometry optimizes accuracy and stability while suppressing disturbance signals, allowing precise measurement, even when operating close to interfering structures. With virtually no installation restrictions, transmitter is suited for small tanks, tall and narrow nozzles, and other processing and storage applications.
|
 Digital Humidity/Temperature Sensors provide long term stability.Honeywell
Golden Valley, MN 55422 3935
Aug 16, 2011
Featuring laser trimmed, thermoset polymer capacitive sensing element, HIH-6130/6131 Series HumidIcon(TM) Sensors offer true accuracy of ±5% RH over compensated temperature range of 41-122°F and 10-90% RH. Optimized Total Error Band eliminates individual sensor testing and calibration. Offering long-term stability of 1.2% RH over 5 yr, series only requires 5-hr rehydration process to correct reflow temperature offset. Digital I2C output allows removal of signal conditioning components from PCB.
|
 Current to Analog Converters measure less than one inch wide.Automation Systems Interconnect Inc.
Mechanicsburg, PA 17055
Aug 15, 2011
Available from 0-1 A to 0-10 A, Current to Analog Converters allow user to monitor flow of current in circuit indicating circuit is operating and load is connected and active. Use of Hall Effect sensor enables both AC and DC currents to be measured. Since 3 different common analog outputs are available, modules will work in any control application where current to analog signal conversion is required.
|
 Miniature Triaxial IEPE Accelerometer delivers linearity of ±1%.Measurement Specialties, Inc.
Hampton, VA 23666
Aug 12, 2011
Available in ±50 to ±2,000 g dynamic ranges, Model 7131A is designed for NVH, engine vibration, road response, modal analysis, structural testing, ride handling, and flight testing. Case-grounded and adhesive-mounted product features hermetically sealed, titanium construction with 4-pin Microtech connector interface and incorporates stable piezo-ceramic crystals in annular shear mode, which provides flat frequency response up to greater than 10 kHz.
|
 MEMS-based Viscometer is used for liquid flow management.RheoSense, Inc.
San Ramon, CA 94583
Aug 11, 2011
Supporting range of applications, µVISC(TM) (micro VISC) employs VROC® (Viscometer Rheometer on-a-chip) with HC chip that supports testing of viscosity ranges to 20,000 mPas or greater. Tests can be completed within 1 min with 3-step operation, and menu-driven application lets user view graphs of results and generate report. Specific uses include testing and evaluating materials such as inks, biologics, chemicals, oils, and other liquids.
|
Pressure Sensors provide ±0.25% FSS BFSL accuracy.Honeywell Advanced Circuits
Minneapolis, MN 55426
Aug 11, 2011
Housed in 0.39 x 0.39 in. package, TruStability® Board Mount Ultra-Low Pressure Sensors include HSC High Accuracy Silicon Ceramic Series and SSC Standard Accuracy Silicon Ceramic Series. Devices provide amplified compensated digital or analog output for reading pressure over full scale pressure span of ±1 to ±30 in. H2O. Total Error Band varies between ±1% and ±3% FSS for HSC Series and ±2% and ±5% FSS for SSC Series. Consuming less than 10 mW, sensors withstand working pressures above 135 H2O.
|
CMOS Sensor targets ultra slim smartphones.OmniVision Technologies, Inc.
Sunnyvale, CA 94089
Aug 10, 2011
Built on 1.1 micron OmniBSI-2 pixel architecture, ¼ in. 8 megapixel CameraChip(TM) OV8850 fits in 8.5 x 8.5 mm autofocus camera module with build height of 4.7 mm. Unit features on-chip temperatures sensor, 2 phase lock loops, context switching, and alternate row exposure for HDR video and still image capture. Integrated scaler allows camera to maintain full field of view in 1080p/30 HD video and preview modes and provides additional adjustable resolution for electronic image stabilization.
|
 DIN Enabled Temperature Sensors support tool-free changeout.Omega Engineering, Inc.
Stamford, CT 06907
Aug 09, 2011
With vibration-resistant construction and IP67 rating, M12 Thermocouple and Pt100 sensors are available with stainless steel or Inconel sheath in both 3 and 6 mm dia and come in standard lengths of 200, 500, 750, 1,000, and 1,500 mm. Termination is achieved via polarized M12 connector with hand-tightened knurled nut. No tools are required for sensor change, minimizing downtime, and available process fittings include BSP, NPT, and metric mounting threads.
|
MEMS Module serves advanced motion-sensing applications.STMicroelectronics
Lexington, MA 02421
Aug 05, 2011
With 6 degrees of freedom, LSM330DL multi-sensor module combines 3-axis sensing of linear and angular motion. It detects acceleration up to 16g and angular rate up to 2,000 dps along pitch, roll, and yaw axes. Able to operate with 2.4-3.6 V supply, module integrates of 3-axis digital accelerometer with 3-axis digital gyroscope. Mechanical sensing structure promotes thermal and mechanical stability, while power-down and sleep modes and embedded FIFO memory block conserve energy.
|
 AC Current Sensors provide linear output voltage.Pulse Electronics
Trevose, PA 19053
Aug 04, 2011
Without requiring core, Sidewinder(TM) sensors provide linear output voltage over dynamic range from 0.1-1,000 A. This technology for AC current sensing, based on the Rogowski Coil principle, offers phase error of less than 0.05° and 100 kHz bandwidth. Products meet Class 0.2 percent accuracy limits defined by IEC 62053-22, ANSI C12.20 standards for currents from 0.1-200 A and above, as well as Class 1 requirement for immunity to external magnetic fields.
|
 Current Transducers monitor machine current usage.NK Technologies
Campbell, CA 95008
Aug 04, 2011
With open collector transistor frequency output design, ATQ Series is used as input to high-speed counter or frequency PLC modules, panel meters, or programmable relays, to monitor machine current usage to within ±1% of range. Multiple ranges from 0-2 to 0-200 A are available to meet needs of particular applications. Split-core enclosure facilitates installation by eliminating need to disconnect monitored conductor to install sensor.
|
Taste Sensing System mimics human tongue.C. W. Brabender Instruments, Inc.
South Hackensack, NJ 07606
Aug 04, 2011
Using multi-channel artificial lipid membrane sensors, Model TS-5000Z imitates taste reception of food goods and pharmaceuticals and interprets them as numerical data. Quantification of taste data is handled via original algorithms and can be displayed in various ways through array of graphing tools. In addition to evaluation of initial taste, instrument also measures aftertaste, including richness, sharpness, bitterness, and astringency.
|
 Microphone and Preamplifier allow testing to +120°C.PCB Piezotronics Inc.
Depew, NY 14043 2495
Aug 03, 2011
Combining condenser microphone and preamplifier, Model HT378B02 helps overcome high temperature testing challenges associated with acoustic measurements in environmental chambers or other high temperature applications. Unit is used by test engineers to measure sound pressure amplitude and perform frequency analysis to minimize noise, identify resonance frequencies, and preserve human hearing. Typical applications include automotive engine testing, aerospace engine tests, and pump analysis.
|
 NDIR Transmitters measure CO2 and temperature.Dwyer Instruments, Inc.
Michigan City, IN 46361
Aug 03, 2011
Suited for monitoring CO2 concentration and temperature in schools, office buildings, and other indoor environments, Series CDT helps achieve LEED® certification. Transmitters utilize single-beam, dual-wavelength, non-dispersive IR sensor to automatically correct measurement in both occupied and unoccupied buildings against aging effects. Universal outputs allow user to select 4-20 mA, 0-5 Vdc, or 0-10 Vdc to work with virtually any building management controller.
|
 Cylinder Pressure Sensor increase product life in engines.Danfoss Automatic Controls Div., Danfoss, Inc.
Baltimore, MD 21236
Aug 02, 2011
Designed to meet harsh environment of diesel and gas engines, MBS 1800 allows 2- and 4-stroke engines to operate with higher than nominal output. Crystal technology is utilized to extend operating life as well as reduce fuel consumption. Available in integrated and inline versions, sensor has pressure range up to 250 bar, overload pressure to 300 bar, and temperature range up to 350°C. Frequency response is 20 kHz, and natural frequency is greater than 90 kHz.
|
Energy Monitoring System delivers data via web browser.E-Mon Corp.
Langhorne, PA 19047
Aug 02, 2011
Suited for campus and multi-building facility applications, Web-Mon(TM) Enterprise Edition provides one-page dashboards of historical and real-time energy use via standard web browser over Modbus IP LAN/WAN networks using Modbus TCP/IP as communication protocol. System displays electrical consumption, peak demand, power factor, Volts, Amps by phase, and VARs. Internal memory stores up to 36 days of 15-min interval data, and user alerts are emailed when kW/kWh usage alarm setpoints are exceeded.
|
 DIN-Rail DC Current Sensors optimize PV energy production.WAGO Corp.
Germantown, WI 53022
Aug 01, 2011
Designed to help identify defective or damaged PV modules, Model 789-620 measures DC currents from 0-80 Adc, while Model 789-621 measures 0-140 Adc. Equipped with dual RJ-45 interfaces, sensors transmit data via RS-485 serial communication lines up to 4,000 ft with accuracy of 0.5%. Feedthrough configuration eliminates need to terminate conductors. Operating in temperatures from -20 to +70°C, both models are addressable via on-unit DIP switch and include operational status LED.
|
 Thermal Gas Mass Flow Meter suits water/wastewater treatment.Fluid Components Intl.
San Marcos, CA 92069 5115
Aug 01, 2011
Featuring plug-in card replacement that can be changed out in field to adapt to plant's network communication needs, Series ST100 measures gas mass flow rate, total flow, temperature, and pressure, depending on model. Basic insertion style air/gas meter has thermal flow sensing element that measures flow from 0.25-1,000 SFPS with accuracy of ±0.75% of reading and ±0.5% of FS. Graphical, multivariable, backlit LCD continuously displays all process measurements and alarm status.
|
(Showing headlines 401 - 420) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362
|
|
|