Sensors, Monitors & Transducers
(Showing headlines 3801 - 3820) << 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 ...
|
Conductivity Sensor targets sanitary applications.Emerson Process Management / Process Liquid Division / Uniloc Division
Irvine, CA 92606
Dec 10, 2007
Compatible with Model 1056 Intelligent Analyzer, Model 410VP PUR-Sense 4-electrode sensor provides linearity between 0.1 µSiemen/cm to 600 mSiemen/cm. Alternating current is injected through outer electrodes while analyzer measures voltage across inner electrodes. Integrated Pt1000 RTD makes contact with process liquid through SS capsule flush with sensing face. Sanitary connections include 1.5 in. tri-clamp, 2 in. tri-clamp, Ingold G1-Ľ, or Varivent® Process Connection.
|
Viscosity Sensor obtains lab-compatible results.Vectron International
Hudson, NH 03051
Dec 10, 2007
Suited for in-situ viscosity measurements, ViSmart(TM) sensors can correlate to data acquired from lab instrumentation for real-time, inline oil condition monitoring applications. Universal plug-n-play connectivity enables integration with and into other handheld products. Complimenting IR spectroscopy and other bulk property sensors, solid-state solution exhibits accuracy levels from 91-99% and provides instantaneous on-line viscosity and temperature data.
|
QVGA TFT Modules offer sunlight readability.Phoenix Display International, Inc.
Tempe, AZ 85283
Dec 10, 2007
Model PDI-T320240SR-5.7 sunlight-readable 5.7 in. TFT features 320 x 240 pixel resolution and is available with or without touchscreen. Illuminated with high-intensity white LEDs, it offers brightness of 300 cd/m2, contrast ratio of 400:1, and response time of 15 ms. Device also utilizes HX8218A and HX8615A drivers. TFT cell is manufactured using high-aperture panel technology, high transmittance color filters, and anti-reflective polarizer scheme.
|
IEEE 1588 MCU and Module perform time synchronization.Imsys Technologies AB
SE-194 61 Upplands Väsby Sweden
Dec 10, 2007
Addressing IEEE 1588 clock synchronization standard, IM3220-BA10 MCU and single board reference module deliver telecom, ITU G.8261, compliance. Microcontroller measures 24 x 45 mm, and user-programmable on-chip microcode enables it to adapt to range of embedded applications. Able to analyze and act on gate level in real time, solution supports two 10/100 Ethernet ports, 3 UARTs with 920 kbps, I˛C or SPI port, and 8 DMA channels with sustained 83 MB/s throughput.
|
Ambient Particulate Monitor has touchscreen user interface.Thermo Fisher Scientific
Waltham, MA 02454
Dec 10, 2007
TEOM Series 1405 comes in 4 models providing ome to three PM measurements, PM-10, PM-2.5 (Fine), and PM-Coarse (PM-10-2.5), and FDMS option is available to account for volatile and semi-volatile fraction. Each model is delivered with network-ready configuration with user interface that allows access to system and TEOM data, settings, and instrument conditions. System's default data output consists of a running 1 hr and 24 hr average mass concentration updated every 6 minutes.
|
Monitoring Devices measure oxygen in blood.SPO Medical, Inc.
Simi Valley, CA 93065
Dec 07, 2007
Suited for use by medical professionals, hospitals, and managed care facilities, PulseOx 6000(TM) and PulseOx 6100(TM) are finger and hand held devices, respectively, that use Reflective Pulse Oximetry technology for measurements of blood oxygen saturation and heart rate. Units include AutoSpot(TM) technology for patients suffering low perfusion.
|
 Temperature Transmitter offers plug-and-play operation.Nanmac Corp.
Framingham, MA 01702 2469
Dec 06, 2007
Suitable for use in research and industry applications, F11-40 Series is designed to fit all thermocouples and RTDs. It has no dip switches, jumpers, or solder points and can transmit full sensor range or be scaled to any specification. Factory-calibrated solution employs loop-power with 4-20 mA outputs and can be rail- or head-mounted. In-head LCD is optional.
|
 Temperature DAQ Instruments are web-enabled.Measurement Computing Corp.
Norton, MA 02766
Dec 06, 2007
Ethernet-compatible WEB-TEMP and WEB-TC let users take temperature measurements and monitor them via Internet. Both feature built-in web servers that write temperature data to their own webpage, were users can access information and configure sensors. WEB-TEMP provides 8 temperature input channels, each supporting all common temperature sensors, and 8 bits of DIO. WEB-TC offers similar functionality but only supports thermocouple sensors.
|
 Rotary Position Sensors utilize touchless technology.Novotechnik U.S., Inc.
Southborough, MA 01772
Dec 06, 2007
Suited for mobile and harsh environments, RSC Series features non-contact technology with rotating shaft, while Vert-x E Series has no shaft, but includes round position marker that mounts separately from detecting sensor component. Sensors offer programmable angular range to 360° and resolution to 14 bits. They range from miniature units measuring 13 mm dia for use in tight applications to rugged 48 mm rotary angle models sealed up to IP69K for adverse conditions.
|
FOUNDATION Fieldbus Temperature Transmitter is bus-powered.Moore Industries International, Inc.
North Hills, CA 91343
Dec 06, 2007
Requiring 10.5 mA to operate, programmable Model TFZ allows up to 32 field devices (126 with repeaters) to be networked onto one FOUNDATION Fieldbus H1 segment. It has 20-bit input resolution, RFI/EMI protection, ambient temperature compensation, and operates in -40 to +85°C temperatures. Rated NEMA 4X/IP66, TFZ can be set from control room over segment wiring to handle 14 RTD types, 9 thermocouple types, as well as direct mV and resistance/potentiometer inputs.
|
 Differential Pressure Gauge provides 0.1% accuracy.Crystal Engineering
San Luis Obispo, CA 93403
Dec 05, 2007
Intrinsically safe and ATEX certified, wet/wet Model XP2i-DP features burst disc that protects sensor from over-pressure on low side connection. Digital gauge provides datalogging capabilities and can be programmed for custom engineering units. Available in panel mounting and portable configurations, unit is tested and calibrated inside environmental test chambers using computer-controlled pressure controllers.
|
 Particulate Transmitter utilizes induction sensing.Dwyer Instruments, Inc.
Michigan City, IN 46361 0373
Dec 05, 2007
Usable as dust collector emissions monitor and leak detector, standard Series PMT is designed for general maintenance planning and process protection applications. Adjustable linear or logarithmic output scaling enables trending of baseline and high peak emissions that are caused by filter cleaning cycles and developing leaks. Protective layers on probe work with induction-sensing to ensure reliable operation with all types of particulate.
|
Wheel-Measuring System suits heavy-load vehicles.Kistler Instrument Corp.
Amherst, NY 14228 2119
Dec 05, 2007
Designed for measuring forces and moments on tires for trucks and other heavy goods vehicles, RoaDyn® S6HT TT (Tire Testing) is rotating 6-component measuring system for wheel and tire test that can be used like measuring hub. It offers measuring range of up to 220 and 100 kN in radial and axial direction, respectively. Modified outer part with different bolt patterns and adapter flange allows standard wheels to be mounted.
|
Diagnostic System wirelessly monitors equipment health.Honeywell
Golden Valley, MN 55422 3935
Dec 04, 2007
OneWireless(TM) Equipment Health Monitoring (EHM) transmits complete spectral information, including vibration amplitude and operating parameter data, from field to plant control room. This 8-channel (4x vibration, 4x 4-20 mA) device communicates over OneWireless industrial mesh network, collecting acceleration, velocity, temperature, and bearing condition data for delivery to process operators and maintenance personnel to alert them of equipment problems.
|
 Encoder IC enables measurement of linear position.austriamicrosystems AG
Premstatten Austria
Dec 03, 2007
Combining Hall elements and signal processor on one silicon chip, Model AS5305 provides linear position measurement via single- or double-track multi-pole magnetic strip sliding over IC. Unit supports magnetic strips with pole-pair dimensions between 2.26 and 5.91 mm. In conjunction with multi-pole magnetic ring, IC can also be used as off-axis device for rotational measurements. Housed in lead-free TSSOP20 package, device operates at 5 V over -40 to +125°C ambient temperature.
|
 M8 Inductive Sensor enables compact system designs.Contrinex, Inc.
Lombard, IL 60148
Dec 03, 2007
Supplied in 16 mm long, AISI 303 stainless steel housing, 620 series sensor features built-in amplifier and operating distance of 2 mm. Sensing range is completely stable from -25 to +70°C, and max switching speed is 3 kHz. Suited for embedding into machines and assembly fixtures, sensor is protected to IP67 and can be flush mounted. Unit is fitted with LED operation indicator and includes short circuit, inverse polarity, and surge protection.
|
DC Current Transducers have bipolar measurement abilities.LEM Holding SA
Plan-les-Ouates CH-1228 Switzerland
Dec 03, 2007
Measuring 174 x 86 x 54.1 mm, DH Series split-core transducers combine Hall-effect technology and signal conditioning in one housing with rectangular sensing aperture for non-contact measurement (supporting up to 104 x 40 mm busbars or 40 mm cables). Products offer choice of primary current measurement from 500-2,000 A and provide absolute accuracy of better than 1% of nominal current value. Bipolar measurement value is delivered via 4-20 mA output.
|
Photoionization Detector determines outdoor VOC levels.RAE Systems
San Jose, CA 95134
Nov 30, 2007
Offering measurement range of 0-5,000 ppm and response time under 3 sec, MiniRAE Lite is intended for outdoor environmental and construction site use where hydrocarbon-based VOCs and chemicals pose toxic threat. Waterproof, nonintrinsically safe unit has 3-button interface that can be operated by users wearing up to 3 layers of gloves. Humidity compensation accommodates rapidly changing environments, and backlit graphical display ensures viewable readings in any light condition.
|
Submersible Level Sensors feature removable, reusable cage.Automation Products Group, Inc.
Logan, UT 84321
Nov 30, 2007
Equipped with vented, watertight cable, PT-500 Series delivers 4-20 mA solid-state signal while submerged up to 450 ft. Removable stainless steel cage connects to sensor with snap ring and enables use in harsh environments. IP68-protected transmitters are temperature compensated and tested to deliver accuracy of 0.50% of span. Installed with surface mount technology, sensors are suited for sewage lift stations, tank liquid level measurement, water and wastewater.
|
 Display Meter indicates level of storage tanks.MTS Systems Corp. - Sensor Div.
Cary, NC 27513
Nov 29, 2007
Communicating via Modbus interface, Side Tank Indicator works with Level Plus® MG transmitter to display product only, product and temperature, or product, interface, and temperature. Outputs from transmitter are communicated via 4-wire multi-drop power and data bus. Display can show measurement in feet, inches to 1/16 in., and temperature to 1 decimal point. Available with explosion-proof housing, display includes 2 relays, 4-20 mA output, 120/240 Vac input power, and 24 Vdc to gauge.
|
(Showing headlines 3801 - 3820) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392
|
|
|