|
|
|
|
|
Sensors, Monitors & Transducers
(Showing headlines 2441 - 2460) << 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 ...
|
Cable Fault Locator can detect faults up to 15 km.GAO Tek Inc.
Toronto M1B2K4 Canada
Aug 06, 2009
Combining OTDR and Intelligent Bridge Testing functions in one unit, telephone cable fault locator, model 98 allows examination of all kinds of patch cords, ribbon or bunched pigtails and installation and maintenance of fiber optic, telecommunication and CATV networks. Product features LCD screen, backlight display, low voltage warning, automatic power off and energy-saving design. It has dead zone distance of less than 1 m, and detects breaks and micro-bends even for jacketed fibers.
|
 Sensors increase control quality of EHR systems.Bosch Rexroth AG Industrial Hydraulics
Germany
Aug 05, 2009
Both AN2/30 angle sensor and KMB4 draft sensor enhance quality of electrohydraulic hitch control (EHR) systems. Former utilizes non-contact measuring principle that permits all measuring ranges up to 360°. Configuration of several Hall elements renders sensor insensitive to mechanical tolerances and temperature. With KMB4 draft sensor, measuring element is permanently secured in sleeve via crimp technology. This minimizes hysteresis and increases characteristic-curve stability.
|
 Humidity Sensor/Transmitter has probe design.E+E Elektronik GmbH
Engerwitzdorf A-4209 Austria
Aug 05, 2009
Allowing for precise measurement of relative humidity in air from 0-100% RH, EE061 series is suited for use outside, in stables, storage rooms, or greenhouses. It operates from supply voltage of 9-28 Vdc, mrsdutrd 160 mm long, handles temperatures from -40 to 60°C, and comes with 0.5 or 3 m long fixed connection cable. Options include 4-wire passive (sink) temperature output, and mounting flange, and radiation shield for outdoor applications.
|
 Metal Detector features Windows-style color touch screen.Safeline Metal Detection, Inc.
Tampa, FL 33634 3009
Aug 04, 2009
Available on Pipeline, Gravity Flow, and Tablex 2 pharmaceutical units, PowerPhasePRO detects and automatically rejects ferrous, non-ferrous, and irregularly shaped and difficult to detect non-magnetic stainless steel in wet or conductive products. Change free running mode enables multiple products to be run at single setting, while built-in condition monitoring provides advanced warning of maintenance needs before failure.
|
 Oxygen Sensor helps minimize beer losses in filling plants.Mettler Toledo, Inc.
Columbus, OH 43240
Aug 04, 2009
Based on fluorescence quenching technology, InPro6970i features minimal need for maintenance and calibration. Optical sensor, when connected to transmitter, automatically uploads data which includes information on stresses that sensor has been exposed to, such as number of CIP cycles. From this, current status is relayed to user who can be informed on sensor maintenance requirements.
|
 Universal Load Cells offer +10 Vdc full range output.Sherborne Sensors Limited
Hampshire RG21 6YH United Kingdom
Aug 04, 2009
Designed to measure both tension and compression loads, Series SS5000 offers 4 measurement ranges from ±250 to ±2,000 N. Units feature integral amplification and internal stainless steel load cell element, which offers resistance to overload, shock, and corrosion. Wheatstone bridge design is fully compensated for temperature effects on zero output and sensitivity. Measuring 17.52 in. dia x 12.21 in. long, miniature strain gauge load cells weigh just 8 oz.
|
 IEPE Accelerometers can withstand ±10,000 g overshock.Measurement Specialties, Inc.
Hampton, VA 23666
Aug 04, 2009
Designed for shock and vibration measurement, Models 7104A (Side Connector) and 7105A (Top Connector) measure less than 0.75 in. high and weigh less than 8.8 g. Stainless steel devices feature welded construction, bandwidth greater than > 12 kHz, and are offered in ranges ±50 to ±500 G with operating temperatures from -55°C to +125°C. Stud mounting and 10-32 connectors with optional cable facilitates installation; adhesive mounting and magnetic mounting adaptors are also available.
|
 Pressure Transducer tolerates extreme space environments.Paine Electronics, LLC
East Wenatchee, WA 98802
Aug 03, 2009
Available in 2.47 in. in length by 0.82 in. diameter package and weighing only 4.0 oz, Miniature S-Class Transducer Series (Mini S-Class) provides accurate and reliable measurements at pressure ranges from 0-500 to 0-5,000 psis. Unit features radiation hardening up to 100 KRad (Si) total dose, immunity to Single Event Latchup to high-level signal amplification, 0-5 Vdc output, and built-in Class S QML-V/ELDRS free electronics.
|
 Thickness Gauge features automatic substrate recognition.BYK Gardner USA
Columbia, MD 21046 2729
Aug 03, 2009
Offering measuring range to 120 mil for Fe and NFe substrates, one-handed byko-test 4500 requires no cable or calibration when changing from ferrous to non-ferrous substrates. It has integrated, non-wearing ruby probe tip to protect probe and surface of measured area. Ready to use instrument comes with carrying case with zero plates, calibration certificate, operating instructions, and batteries.
|
Solid-State HVAC Sensor eliminates need for Freeze Stat.Minco
Minneapolis, MN 55432
Aug 03, 2009
Designed to protect chillers in air handling equipment used by commercial buildings, Chill-Out(TM) Combination Sensor replaces Freeze Stat but has 2 sensors: one low-temp cut-out sensor and one independent averaging-temp sensor. Dual-sensor package delivers accurate measurements and eliminates need to install separate averaging sensor. Mounted in any direction, product offers low-temp sensitivity within 12 in. segment and has no capillary tubes to break, leak, or kink.
|
 Flow Meter uses up to 4 mass flow sensing points.Sierra Instruments, Inc.
Monterey, CA 93940
Jul 31, 2009
With accuracy of ±1% reading plus 0.5% of full scale, Multi-Trak(TM) Model 670S measures mass flow rates in large ducts or stacks that have non-uniform velocity profiles, dirty gas streams, and fast velocity and temperature changes. Microprocessor-based touchscreen HMI is used to collect, visualize, and store flow data, as well as set up individual sensor points. Meter features 1 sec response to changes in flow rate and Dry-Sense(TM) Technology, which eliminates sensor drift.
|
 Sheathed Thermocouple suits space restricted applications.Okazaki Manufacturing Company
Rhondda Cynon Taff CF15 7AF United Kingdom
Jul 30, 2009
Featuring outside diameter of 0.08 mm, Sheathed Thermocouple can be bent on installation without causing damage or loss of performance. Unit comprises metal sheath with thermocouple elements inside that are tightly packed with mineral powder, which insulates thermocouple elements from one another and from sheath. With response time of less than 1 ms, device is suitable for measuring temperature of any small object or material.
|
Master Gauges meet needs of pressure instrument testing.Ashcroft Inc.
Stratford, CT 06614
Jul 30, 2009
Type 1082 master gauges feature 0.25% FS accuracy in ranges from vacuum through 10,000 psi and are available in 4½, 6, and 8½ in. dia versions. External zero adjuster, temperature compensation, and Monel® wetted parts ensure precision and media compatibility. Suited for field calibration, 3 in. Type 1084 pocket test gauges cover ranges to 1,000 psi with 0.5% FS accuracy.
|
Ethernet I/O Device allows remote monitoring over GPRS.Moxa Inc.
Brea, CA 92823
Jul 30, 2009
Featuring 4 AIs, 8 DIOs, and 2 relay outputs, ioLogik W5340 Active GPRS I/O is suited for hard-to-wire locations for remote monitoring and alarm applications. Remote unit will automatically establish communications with Active OPC Server using fixed IP and can be integrated with SCADA systems. It also includes power saving and data logging features as well as active alarm message with real-time stamp including SMS, SNMP Trap, TCP, and email.
|
 Dust Compliance System performs opacity measurement.AMETEK Solidstate Controls
Columbus, OH 43085
Jul 29, 2009
Utilizing 3 technologies, Model 4500 Mk III performs reliable stack opacity measurement and dust concentration monitoring. Homogeneous LED light source, combined with Flood LED, helps achieve optimal stability and accuracy, while this solid-state system also lends to reliable operation. Featuring fully automatic zero checking and drift compensation, system is able to report data as opacity, dust density, or optical density.
|
 IP-Addressable Device provides remote power management.Para Systems, Inc.
Carrollton, TX 75007
Jul 29, 2009
Used with security systems, telephone/VoIP systems, servers, and network peripherals, 2-outlet RPM 1521 allows users to send command via web browser to cycle power off and on. Each receptacle can be independently monitored and managed, including scheduled shut-downs and reboots. Auto-ping feature monitors and auto-detects availability of attached equipment. If no response is detected, device can send SMS text message, broadcast email, and/or send SNMP trap notification to user.
|
 Wireless Device integrates with facility monitoring systems.RLE Technologies
Fort Collins, CO 80524
Jul 29, 2009
Equipped with 418 and 900 MHz radio receivers, FDS-Wi receives signals from transmitters sensing temperature, humidity, motion, power, dry contact, analog (4-20 mA), 0-5 Vdc, and 0-10 Vdc signals, and integrates them to facilities monitoring systems in form of SNMP, Modbus TCP/IP, Modbus RTU, and BACnet/IP. Device can receive signals within 30.48 m of open air space with 418 MHz frequency and up to 402.34 m of open air space with 900 MHz frequency.
|
 Sensors detect damaging unit vibration levels.ACE Controls, Inc.
Farmington, MI 48335
Jul 29, 2009
Connected to devices such as linear modules, rotary actuators, and grippers, V-Sensors detect damaging unit vibration levels in automation process. They can also signal when industrial shock absorber is nearing end of its life-cycle, helping prevent repair, maintenance, and downtime. Available in PNP, NPN, and analog versions with various installation adapters, sensors are also offered with securing clamps available in various diameters.
|
 Triaxial Accelerometer is designed for modal analysis.Dytran Instruments, Inc.
Chatsworth, CA 91311
Jul 29, 2009
Along with 2-wire internal IEPE electronics, Model 3023A9 contains 3 miniature quartz laminar shear mode accelerometer elements mounted orthogonally to each other to single support and welded into titanium housing. Device mounts using 10-32 tapped hole in base, has sensitivity of 1 mV/g, single connector, is hermetically sealed, and weighs only 4 g. Labels of X, Y, and Z axes are laser marked in large font size on 3 orthogonal faces.
|
 Position Sensor is designed for use in limited space areas.ASM Sensors, Inc.
Elmhurst, IL 60126
Jul 29, 2009
Available in 0.32 in. high and 1.10 in. wide industrial grade housing, maintenance-free non-contact linear position sensor PCFP25 series utilizes magnetostrictive sensing technology. Absolute position sensor is available with measurement range up to 18 ft, and provides analog outputs of 0-10 Vdc and 4-20 mA. Shock and vibration resistant sensor achieves IP64 protection rating, while 2 different styles of mounting hardware facilitate installation. CAN-Bus versions are also available.
|
(Showing headlines 2441 - 2460) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392
|
|
|