Quantcast
 
Search for: Search what?
Nov 22, 2008  
 Sections
Latest New Product News
Industrial Market Trends
Association & Government News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP

Advertisement
Safety & Security Equipment -> Fire Handling Equipment and Systems -> Others


Others


   Add to Google      PDF icon

(Showing headlines 41 - 60)   1 2 3 4
Fire Detection Products interface with existing units.

Fire Detection Products interface with existing units.

NOTIFIER Fire Systems
Northford, CT 06472
Nov 17, 2004 Onyx Series includes Model 640 Fire Alarm Control Panel, ACPS Addressable Power Supply, XPIQ multi-channel audio transponder, RFX wireless detection systems, and Acclimateâ„¢ Plus detector. All have black patterned look, along with network, panel, and peripheral device designs. Units can be linked together to form integrated solutions for any life safety challenge.

Pike Pole adapts to every situation.

Pike Pole adapts to every situation.

Akron Brass Co.
Wooster, OH 44691
Oct 08, 2004 Eliminating need to carry several different pike poles to fire ground, Adapt-a-Pole consists of one handle and various hooks for different purposes. User can change hooks by disengaging locking mechanism, then selecting and attaching desired hook for job.

Stream Foam Tube offers 2 methods of dispersion.

Stream Foam Tube offers 2 methods of dispersion.

Akron Brass Co.
Wooster, OH 44691
Oct 08, 2004 Style 3626 Master Stream Foam Tube features dispersion jaws and optional electric actuation. By flipping one switch, 800 gpm foam tube can be changed between straight stream and flat disperse spray stream. In addition, product includes manual override for changing streams if power is disrupted. It can be installed on Akron Brass StreamMaster Electric monitor for all-electric operation.

Elastomeric Spray is used in firestopping and soundproofing.

Elastomeric Spray is used in firestopping and soundproofing.

Acoustical Solutions, Inc.
Richmond, VA 23228
Oct 06, 2004 SpecSeal AS Spray provides spray-applied protection of joints and penetrations of all types. Professional-grade, latex-based acoustical coating suits construction joint applications such as floor-to-floor, floor-to-wall, wall-to-floor, wall-to-wall, and head-of-wall. Binder system is totally resistant to water and will not re-emulsify after drying. Clean-up is done via soap and water, and drying properties help avoid washouts.

Fire Protection System provides pre-wired/piped solution.

Fire Protection System provides pre-wired/piped solution.

Tyco Engineered Products & Services
Exeter, NH 03833
Sep 10, 2004 MCC (Mist Control Center) AquaMist Delivery System is pump skid assembly with pump, controller, control valves, deluge valve, control panel, and system strainer. System also incorporates AquaMist® fire protection system, which uses mist application nozzles that produce reduced droplet sizes in discharge pattern. In fire condition, fine mist is transformed to steam, expanding each water droplet over 1,600 times its initial volume and displacing oxygen.

Air Sampling Smoke Detector protects small, critical areas.

Air Sampling Smoke Detector protects small, critical areas.

Xtralis Inc.
Norwell, MA 02061
Jul 09, 2004 VESDA LaserFOCUS(TM) features SonicFlow(TM) ultrasonic flow sensing, circular display, and pre-engineered piping options. It provides tolerance to contamination, immunity to temperature changes and altitude, and absolute flow measurement in lpm. Dual-stage filter and clean air bleed-in help prevent contamination by dust and other air borne contaminants. Illuminated dial, LEDs, and related icons provide identification of smoke growth and alarm conditions.

Analog Smoke Sensors feature low flow technology.

Analog Smoke Sensors feature low flow technology.

Fire Control Instruments, Inc.
Waltham, MA 02451 1122
Jul 02, 2004 Series ADP Photoelectronic Air Duct Smoke Sensors detect smoke at air-speed velocities of 110–4,000 fpm. By sampling air currents passing through ducts, units shut down fans, blowers, and air conditioning systems, preventing spread of toxic smoke and fire gases. Series includes Model ADP non-relay, 2-wire device requiring signaling line circuit power only and Model ADP-R 4-wire, relay unit requiring signaling line circuit power and 24 Vac/dc or 120/240 Vac.

Fire Alarm System offers distributed audio capabilities.

Fire Control Instruments, Inc.
Waltham, MA 02451 1122
Jun 03, 2004 NetSOLO® Broadband delivers full-network control and communications, digital messaging, live voice instructions, and fire fighter telephone communications through distributed network fire alarm system, all on single pair of wires. It incorporates existing 7100 panels and can be expanded to meet growing application demands. System uses Boolean logic programming and Digital Signal Processor.

Control Panel has remote programming/monitoring capabilities.

Fire-Lite Alarms
Northford, CT 06472 1653
May 21, 2004 Manufactured with SMT, MS-9600 V2 addressable fire alarm control panel is offered with Digital Alarm Communicator Transmitter option that provides remote site upload/download and remote monitoring capabilities. It also lets technicians diagnose system problems remotely. Features include 14.4 kbaud modem, 2 Notification Appliance Circuits, and fire protection technologies such as Maintenance Alert, Automatic Detector Test, and Sensitivity Printout.

Flashlight features unbreakable ABS construction.

Flashlight features unbreakable ABS construction.

Pelican Products, Inc.
Torrance, CA 90505
May 06, 2004 Available in alkaline and rechargeable models, Little Edâ„¢ right-angle, Xenon flashlight resists water and chemicals in hazardous locations. Stainless steel clip attaches unit to turnout coat or shirt pocket for hands-free use. Switch is easily operated, even with gloves. Available in black and yellow, flashlight includes safety lanyard and is suited for firefighters.

Fire Detectors offer application-specific technology.

Fire Detectors offer application-specific technology.

Faraday, LLC
Tecumseh, MI 49286
Jan 15, 2004 Suited for small- to medium-size installations, FireSmartâ„¢ Application Specific Detectors employ software algorithms and neural network to sense smoke and heat. To eliminate false alarms, detectors are adjustable for optimum response in 11 environments, such as healthcare facilities, office/retail environment, dormitory or hotel room, HVAC duct, and warehouses. Units ignore cigarette smoke, dust, and car exhaust and offer early warning to true threat of fire.

Fire Control Panel has reporting features for DACT circuit.

Fire Control Panel has reporting features for DACT circuit.

Fire Control Instruments, Inc.
Waltham, MA 02451 1122
Oct 31, 2003 Series 7100 multiprocessor-based fire control panel system comes with Windows®-based Field Configuration Program (FCP-7100)/System Operating Software (SOS) v6.1. It enables control panel to read specific sensitivity level of each sensor and allows system to compensate for changes due to age, dust accumulation, or other environmental factors. Software includes 4 conditions viewable on display to aid in isolating DACT FAULTS conditions.

Air Quality Sensor has 0–0.6 mg/m³ range.

Air Quality Sensor has 0–0.6 mg/m³ range.

Sharp Microelectronics
Camas, WA 98607 9489
Sep 05, 2003 Model GP2Y1010AU detects particulate matter, smoke, or dust suspended in air. Unit measures 46 x 30 x 17.6 mm, operates on 5.0 V, and has current dissipation of less than 20 mA. Suited for air purifiers and air cleaning systems, device may also be used in various industrial applications. When used in smoke detection system, unit triggers alarm or system shut-down in case of burning or overheating conditions to prevent damage to automated equipment.

Control Panel controls release of extinguishing agents.

Control Panel controls release of extinguishing agents.

Simplex
Westminster, MA 01441
Jul 17, 2003 Simplex® 4004R Suppression Releasing Panel suppresses fires in computer rooms, petrochemical and power plants, and high-risk locations. Product controls release of extinguishing systems such as Inergen®, FM-200, preaction, water spray deluge, and carbon dioxide. Capable of handling one or two hazard areas, product also provides emergency notification using horns or strobes. Panel can capture detailed history of all trouble, alarm, and releasing events.

Firestop Plug seals wires in walls and floors.

Firestop Plug seals wires in walls and floors.

Hilti Inc.
Tulsa, OK 74121
Jun 30, 2003 Designed for permanently or temporarily sealing single or bunched cables in fire walls and floors, model CP 658 flexible, intumescent plug is reusable and repenetrable. Suited for cored or round holes, it provides dust- and fiber-free solution for meeting building and fire codes. Halogen-, asbestos-, and solvent-free plug can be used with FS 657 Fire Block, CP 618 Firestop Putty Stick, and CP 617 Firestop Putty Pad.

Trim Units connect to valves via flexible hoses.

Trim Units connect to valves via flexible hoses.

Viking Corp., The
Hastings, MI 49058 9706
Jun 12, 2003 Available for single and double interlock preaction and deluge, TrimPacâ„¢ pre-assembled, pre-tested trim units can be used with angle-style or straight-through valves. UL/c-UL Listed and FM Approved Products may be used on any size valve in 1½â€“8 in. sizes and can be mounted on wall or on riser. They connect to valves with flexible hoses and come complete with galvanized conventional trim as well as appropriate release trim.

Fire-Alarm Panel is compatible with non-shielded wires.

Fire-Alarm Panel is compatible with non-shielded wires.

Faraday, LLC
Tecumseh, MI 49286
Jun 03, 2003 MPC-1500 Plus intelligent fire-alarm control panel employs UL-approved driver circuit. Loop circuit can operate with straight-laid, non-twisted, non-shielded wire in retrofit applications. Panel features 80-character LCD display, analog addressable detection, programming, and memory capability. It accepts expansion modules to include up to 8 D/B initiating zones. Operating controls and indicators are mounted on door, with mylar label for identification.

Fire Detector Tester reduces programming and test times.

Fire Detector Tester reduces programming and test times.

Siemens Building Technologies Inc.
Florham Park, NJ 07932
Jun 03, 2003 Device Program Unit, for diagnostic testing of fire detectors, is for programming MXL and XLS devices and testing XLS circuits and may also be used as XLS loop circuit driver. Unit operates on rechargeable NiMh or Alkaline batteries, has optional label printer, uses FLASH memory, and has backlit screen. Unit has DB-3S base adapter for testing and programming ILI and ILP series detectors.

Fire Protection System is rated to 250 psi.

Fire Protection System is rated to 250 psi.

Viking Corp., The
Hastings, MI 49058 9706
May 05, 2003 TotalPac2 fail-safe, fire protection units are built on company's EZ Trim and are available in Dry, Deluge, Single-, and Double-Interlock Preaction and Firecycle® III systems. Three models include skid containing pre-assembled trim on 14 ga steel base, remote controlled unit without integrated panel, and fully equipped self-contained unit. Pre-assembled, pre-tested models come in sizes from 1-1/2 to 6 in. and are UL and C-UL Listed.

Intelligent Fire Detector System provides background music.

Intelligent Fire Detector System provides background music.

Siemens Building Technologies Ltd.
Sudbury, ON P3A 2A3  Canada
Feb 13, 2003 FireFinder incorporates audio system with 8-channel digital voice amplifiers that operate in 200 Hz to 12 KHz range. System is used for voice/evacuation emergency notifications and can also provide building-wide communication with surround-sound music and paging. Its 6 in. interface screen simultaneously displays up to 5 events using HAZMAT icons for safety and highlighting critical information. Interface also displays locator maps.




(Showing headlines 41 - 60)   1 2 3 4


Newsroom Advertisers




Home  |  My Newsroom  |  Industrial Market Trends  |  Submit Release  |  Advertise  |  Contact NewsRoom  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2008 Thomas Publishing Company
Terms of Use - Privacy Policy