Fire Suppression System protects mobile machinery.Kidde Fire Systems
Guelph, ON N1H7L1 Canada
Nov 11, 2008
Kidde Sentinel(TM) detects, suppresses, and secures vehicle and machinery fires in extreme environments. This FM-approved aqueous suppression system can be designed to use environmentally non-reportable wet agent AquaGreenXT(TM), dry chemical agent, or combinations of wet and dry agents for primary and secondary protection. Kidde Sentinel NET networked control system and Kidde Sentinel SA-1 control panel provide up to 2 hr of continuous monitoring after vehicle is shut down.
|
Fire Sprinklers are adjustable and concealed.Viking Corp., The
Hastings, MI 49058 9706
Sep 25, 2008
Mirage® adjustable concealed sprinklers are factory-assembled with brass adjustable drop nipple that provides 1 in. of vertical adjustment, and when combined with ½ in. cover plate adjustment, provide total vertical adjustment of 1½ in. Suited for tenant improvement projects, sprinklers are cULus listed and available in 2.8 (40), 4.2 (61), and 5.6 (81) K factors. The sprinklers are also available with 1 in. NPT male or female thread connections.
|
Silicone Sponge meets standards for flame retardance.Saint-Gobain Ceramics & Plastics, Inc.
Worchester, MA 01615
Sep 05, 2008
COHRlastic® R10400 M high-consistency rubber (HCR), closed-cell, silicone sponge meets UL 94 V-0 standard down to 1.58 mm thickness and is manufactured from blend of HCR silicone. Product has tensile strength of 100 psi, elongation of 250%, tear strength of 20 ppi, and temperature range of 100-500°F. Suited for use in equipment in outdoor communication devices, it is designed for high-performance, flame-retardant cushioning, gasketing, and sealing products.
|
Smoke Detector uses crystal-controlled wireless technology.NAPCO Security Group
Amityville, NY 11701
Aug 13, 2008
Enabling precision detection of even minute particles produced by clean-burning fires, GEM-SMK can detect all types of fires including paper, wood, gasoline, polystyrene, and smoldering fires. Photoelectric smoke detector eliminates need for home and business owners to run wires throughout their properties. It includes batteries with 5 yr life, mounting kit, and built in LED status indicator that alerts users when their battery is low or device is in need of cleaning.
|
 Fireproof Boxes protect electrical systems in emergencies.Altech Corp.
Flemington, NJ 08822
Aug 08, 2008
With halogen-free duroplastic construction that eliminates potential for metal-induced short circuits, Altech® fireproof enclosures can sustain flame protection up to 90 minutes in accordance with DIN 4102 Part 12, and offer ingress protection (water leaks) to IP 54 or IP 66. Rugged and shock-resistant units are available in wide range of sizes with 3-, 5-, or 8-pole terminal blocks, depending on model. All versions are self-extinguishing and can be lead sealed.
|
 Fire Sprinkler has concealed design for residential use.Viking Corp., The
Hastings, MI 49058 9706
Aug 04, 2008
Model VK457 flat plate pendent sprinkler has temperature rating of 165°F. Available in 9 standard finishes, sprinkler is offered with 2 cover plate options: 2¾ in. dia cover plate for installations where aesthetics are priority, and 3 5/16 in. cover plate that offers horizontal foregiveability for maximum installation flexibility. Installation tools allow users to remove sprinklers' protective caps and install cover plates from floor, without need for using ladder.
|
Tactical Flashlight can be attached above/below fire helmets.Streamlight, Inc.
Eagleville, PA 19403
Jul 16, 2008
Vantage(TM) hands-free flashlight features C4(TM) power LED technology that produces special safety tail light which enables firefighters and rescue workers to be seen in smoke-filled rooms, blackout conditions, and other emergency situations regardless of direction of light. Weighing 5.14 oz, IPX7 rated unit features light intensity of up to 4,500 candela (peak central intensity) and 80 lumens total system output for 6 hr of continuous runtime to 10% output level.
|
 Fire Protection Valves handle pressures to 350 psi.NIBCO, Inc.
Elkhart, IN 46516
Jul 14, 2008
Featuring nylon-coated finish and EPDM-encapsulated disc for good closure during shut downs, GD6765-8N grooved butterfly valve is gear-operated for slow-close functionality to protect piping from water shock. It is UL-/ULC-listed to 350 psi water working pressure and UL-listed for indoor/outdoor use. Additionally, F697-0 Class 250 iron body gate valve is rated to 300 psi and carries FM/NYC MEA approvals. Grooved double door silent check valve, KG900-W 350, is also available.
|
Fire-Suppression Gel is UL-711 tested.GelTech Solutions, Inc.
Jupiter, FL 33458
Jun 04, 2008
Helping firefighters snuff blazes, FireIce quickly blocks oxygen to fires, asphyxiates them, and prevents them from reigniting. Non-toxic product is fine powder that mixes with water to yield biodegradable, environmentally friendly gel that works in pumpers, tankers, air-drop planes, helicopters, extinguishers, and hand-held sprayers. It does not clog or corrode firefighting equipment and also reduces amount of water consumed when fighting fires.
|
Flame-Retardant Material meets IEC 60695 requirements.Solutia, Inc.
Saint Louis, MO 63166
Jun 03, 2008
Vydyne® GW350 flame-retardant material complies with International Electrotechnical Commission's (IEC) 60695 series of standards, which requires materials to endure fire hazard and toxicity tests to ensure product safety. Designed for E/E applications, especially those used in manufacturing household appliances, product is formulated to exhibit flow properties enabling processability.
|
 Dry ESFR Sprinkler protects cold storage areas.Viking Corp., The
Hastings, MI 49058 9706
May 14, 2008
Model VK501 is supplied from wet system installed in heated space, eliminating need for preaction system and in-rack sprinklers. Offered in single length of 36 in. with 2 in. grooved connection, 165°F unit has K factor of 14.0 (202), and 1½ in. threaded version is also available. Each sprinkler is shipped with 2 insulating boot assemblies that seal clearance space around srinkler barrel, decreasing potential for condensation. VK501 is also cULus listed for use with wet systems.
|
 Duct Smoke Detectors support remote testing capabilities.Air Products and Controls Inc.
Pontiac, MI 48340
Apr 18, 2008
Detector series SM, HS, and SL are all available with UL-Listed and MEA-Accepted MSR-50 Series remote accessories, which provide centralized control for testing and operation of building's duct smoke detection system. While MSR-50RM provides hidden magnet test switch and push button reset, MSR-50RK includes key-operated detector test and reset. Both models are available as single gang remote indicator/control or with addition of single gang strobe assembly.
|
Fire Fighting Device combines 5 emergency-rescue functions.Spartan Motors, Inc.
Charlotte, MI 48813
Apr 16, 2008
Boomer(TM) is Furion®-based product that offers elevation, water discharge, hydraulics and air, electrical, and lift in compact device. System can lift 1,000 lb and has 28 ft master stream that can be rotated 360° and elevated from -10° to +90°. It includes 6,000 W light tower with adjustable lights, connections for high-pressure hydraulic rescue tools, and 2 additional hand-line discharges. Device features SS tubular design and boom is manufactured with extruded aluminum.
|
 Electric Proportioners feature hybrid heaters.Graco Inc.
Minneapolis, MN 55440
Mar 26, 2008
Suited for polyurethane foam and polyurea applications, Reactor E-Series Proportioners include circulation valves with long lasting seals, temperature control board that facilitates component change-outs, and heat transformer that does not require tap settings. With hose heat circuit breaker module, need for in-rush limiter is eliminated.
|
Fire Control Panel is FM approved and cULus listed to UL 864-9.Viking Corp., The
Hastings, MI 49058 9706
Mar 24, 2008
VFR-400 includes 4 programmable class B initiating zones, 2 class B supervisory zones, and 4 programmable output circuits. Onboard, menu-driven programming with 12 pre-installed programs facilitates set-up. Panel is compatible with various initiating devices including linear heat detection, smoke and heat detectors, water flow indicators, low air pressure switches, and manual pull stations. The VFR-400 accommodates multiple voltage applications, including 110/220 V and 50/60 Hz.
|
Concealed Fire Sprinklers offer extended coverage.Viking Corp., The
Hastings, MI 49058 9706
Mar 17, 2008
With 5.6 (81) and 8.0 (115) K factor respectively, Models VK632 and VK634 are cULus listed and FM approved for 135, 155, 175, and 200°F temperature ratings. They include push on, thread off cover plate that installs on inside of sprinkler cup, providing protection from drywall mud, paint, and other debris. Units come with either 2¾ in. dia standard cover plate for installations where aesthetics are a priority, or 3-5/16 in. dia plate that offers greater installation flexibility.
|
 Outlet Boxes and Covers help identify fire alarm circuits.EGS ELECTRICAL GROUP ? APPLETON
Rosemont, IL 60018
Feb 20, 2008
Made of red, epoxy powder-coated steel, fire and safety Outlet Boxes, Extension Rings, and Covers eliminate need for painting at job site. Boxes come in 4 in. and 4 11/16 in. square sizes, measuring 1 ½ in. and 2 1/8 in. deep, with welded or drawn construction to meet needs of commercial applications. Groundskeeper(TM) raised boss enables 3/8 in. ground screw to be threaded into box without contacting mounting surface. Standard flat ground tapped holes are also available.
|
Flame Retardent protects flexible foams.Albemarle Corp.
Baton Rouge, LA 70820
Jan 31, 2008
ANTIBLAZE® 117HF halogen-free flame retardant is formulated for use with flexible foams used in furniture and automobile seats. Offered as alternative to halogen-based flame retardants, high-efficiency, non-scorching product is non-persistent and non-bioaccumulative, per U.S. Environmental Protection Agency criteria.
|
Smoke Detection System features Sample Port-Annunciation(TM).AirSense Technology USA Ltd.
Portland, OR 97223
Dec 24, 2007
MatrixScan(TM) addressable virtual detector matrix system features sampling pipes routed from multiple detectors to crossover points, each with specific detector address. Each crossover is treated as independent device, having multiple alarm thresholds, smoke and level bargraphs. Up to 127 virtual detectors can be assigned per loop. MatrixScan configuration is implemented through function-setting dialog box accessible through Stratos UL Listed and FM Approved Command Modules.
|
Flame Retardants feature halogen-free formula.Songwon Industrial Co., Ltd.
Ulsan 680090 Korea (north)
Nov 13, 2007
Based on Phosphine Oxides, Songflame YA 010 and YA 020 are designed to be reactive with resin backbone, principally epoxies, to give long term stability, while being environmentally safe, non-toxic, and non-corrosive. Based on Phenol/Bi-phenol polyphosphate, Songflame TP100 boosts thermal strength properties in resin matrix and is suited for variety of thermoplastic resins, particularly Polycarbonate, Polycarbonate blends with ABS, and wide range of Polyesters.
|