 Electronic Relays monitor various motor values.Pilz Automation Safety L.P.
Canton, MI 48187
Sep 10, 2008
Designed to monitor voltage, current, temperature, and phase sequence, PMDsigma Relays enable users to set values via rotary knob and save them to chip card. Data remains flexible and can be copied to other units. Model PMD s10 monitors true power of motors with rating up to 11 kW, and can process frequencies from 0-1,000 Hz, making it suitable for dc and ac motors as well as frequency-controlled drives. With relays, users can implement early warning system for hazardous plant conditions.
|
 Relay Interface Modules are electromechanical.Automation Systems Interconnect Inc.
Mechanicsburg, PA 17055
Aug 21, 2008
Featuring DIN rail mounting, coil and contact lead isolation, and voltage kick-back protection, IMRL electro-mechanical relay interface modules come in 1, 2, and 4 pole versions, each carrying maximum load of 10 A. They are available in control voltages of 5, 12, and 24 Vdc and 24, 120, and 230 Vac. Interface modules are offered with fixed relays pre-soldered to printed circuit board, relay socket only, or pluggable relays pre-installed into relay socket.
|
 Power Relay Module is supported by PXI compliant 3U chassis.Pickering Interfaces
Wobum, MA 01801
Aug 11, 2008
Supporting high current and high voltage switching applications, model 40-330 SPST Power Relay Module provides 24 off SPST switches, each capable of switching currents up to 4 A and hot switching voltages up to 250 Vac. Cold switch rating of 1,000 V peak permits unit to be used for high voltage test applications where hot switching is not needed. User connections are provided on 50 way male high voltage D Type connector. Module includes software support for common programming environments.
|
Arc Flash Relays help meet NESC 410.A.3 requirement.Basler Electric Co.
Highland, IL 62249
Aug 08, 2008
Models BE1-50/51B-235 and 237 are self-powered, single phase, overcurrent plug and play replacement relays that help electric utilities meet NESC 410.A.3 requirement by reducing duration of arc through fast fault clearing. Units directly fit into existing case without need for rewiring.
|
 Universal Pushbutton offers 2 accessories.Safety Technology International
Waterford, MI 48327
Jul 23, 2008
With LT-1 Latching/Timer Module, UB-1 Universal Button can be used as latching module, which can be reset with closure of any type. When installed with normally open contact on door, unit will automatically reset without waiting for timer to expire. Digital timing circuit can be set for 15, 30, 45 sec or indefinitely. Featuring 12-24 Vac/Vdc operation, module has Form C contact rating of 3 A at 125 Vac/30 Vdc. Two-inch lens accessory is available to make Universal Button more noticeable.
|
Monitors and Timers protect 3-phase equipment.ATC-Diversified Electronics
Lancaster, PA 17601
Jul 22, 2008
DIN rail mounted DLA Series 3-Phase Monitors protect equipment from adverse conditions such as phase loss (single phasing), undervoltage (brown-outs), and phase reversal (improper sequence). DTA Series Multifunction Time Delay Relays combine multiple timing functions and ranges into one DIN rail-mount package. Both are suited for users and OEMs in water, food, and automation industries.
|
 RoHS Automotive Relays have switching capacity to 40 A.CIT Relay & Switch: Division of Circuit Interruption Technology, Inc.
Maple Grove, MN 55369
Jun 09, 2008
Offering contact arrangement options of SPST N.O., and SPST N.C., A2S Series features mounting bracket and quick connect termination of 6.3 to .250 mm. Units have contact resistance of less than 30 mW, insulation resistance of 100 MW at 500 Vdc, and shock resistance of 147 m/s² for 11 minutes with vibration resistance of 1.5 mm double amplitude 10-40 Hz. Measuring 35.7 x 35.7 x 66.2 mm, relays have operating temperature of -40 to 85°C and storage temperature of -40 to 155°C.
|
 Automotive Relays offer switching capacity to 20 A.CIT Relay & Switch: Division of Circuit Interruption Technology, Inc.
Maple Grove, MN 55369
Jun 02, 2008
With RoHS lead free AgSnO2 contacts, Automotive A4 Series relays offer contact arrangement options of SPST N.O. and SPDT. They have contact resistance of less than 30 mW, switching power of 280 W on single and 2 x 280 on dual package, and switching voltage of 380 Vac, 75 Vdc. Other features include insulation resistance of 100 mW at 500 Vdc, and shock resistance of 100 m/s² for 11 minutes with vibration resistance of 1.27 mm double amplitude 10-40 Hz.
|
 Relay Output Module features USB/104 form-factor.ACCES I/O Products, Inc.
San Diego, CA 92121 1506
May 23, 2008
Measuring 3.550 x 3.775 in., Model USB-IDIO-16 features 16 individually optically isolated inputs and 16 fully protected, solid-state FET outputs capable of switching from 5-34 Vdc at up to 2 A. Unit is compatible with USB 1.1 and USB 2.0 ports and offers hot-plug functionality for quick connect/disconnect. Suited for industrial environments, module includes jumper-selectable filtering per input channel, and polarity insensitive AC/DC inputs that accept up to 31 Vdc or AC rms.
|
 Solid State Relay is microprocessor controlled.Carlo GAVAZZI Automation Components
Buffalo Grove, IL 60089
May 19, 2008
Featuring analog input and proportional output capabilities, RJ1P Series is capable of switching single phase 230, 480, or 600 Vac, up to 50 Aac loads with 5 different operating modes, when controlled by 0-10 Vdc or 4-20 mA signals. Rotary selector stitch is used for selecting preferred mode of operation, either phase angle, distributed full cycle, or 3 types of burst modes (1, 3, and 10 sec). Ready for DIN rail mounting, unit comes with integrated heat sink and varistor.
|
 Solid-State Relays offer high-speed, -frequency switching.Optek Technology, Inc.
Carrollton, TX 75006-6905
May 13, 2008
Designed without switching contacts to promote reliability, OSSR Series come in hockey puck (panel mount) SIP1 and SIP2 packages and incorporate zero crossing circuit that minimizes current and noise surges due to resistive and inductive loads. Solutions lend design engineers ability to switch loads while isolating input from output. Available configurations - dc input/ac output, ac input/ac output, and dc input/dc output - offer range of input, load current, and load voltage values.
|
 Relay targets high-power electronic applications.Cole Hersee Co.
Boston, MA 02127 2467
Apr 22, 2008
Model 48520, 200 A Electronic Relay protects motors and other loads from damage due to overcurrent and overheating and can be used in severe environments. Fully sealed relay features solid-state design that eliminates contact wear and extends service life to 1,000,000 cycles. It can also be used in hard to access locations and labor-intensive installations.
|
 Serial Lock-Out Relay provides remote trip and reset.Electroswitch, Unit Of Electro Switch Corp.
Weymouth, MA 02188 2913
Apr 14, 2008
Available in 3, 5, or 8 decks, Series 24 addressable network device delivers trip-coil monitoring, IRIG-B sequence-of-events reporting, system battery monitoring, self-diagnostic reporting, and 2 auxiliary monitoring inputs. Unit frees up RTU points, minimizing point-to-point wiring and facilitating load-shedding. Equipped with manual reset handle for Lock-Out Relay local control, SLOR is rated 30 A/600 V continuous with circuit-breaker coil providing ability of 95 A/125 Vdc.
|
 Relay has maximum switching power of 60 W.CIT Relay & Switch: Division of Circuit Interruption Technology, Inc.
Maple Grove, MN 55369
Feb 26, 2008
Series J860 monostable, high dielectric relay with 2.5 kV surge strength conforms to FCC Part 68. Measuring 15.0 x 7.5 x 9.5 mm, relay is DPDT with coil voltage choices of 3, 4.5, 12 and 24 Vdc. Featuring max switching voltage of 250 Vac, 220 Vdc and switching current of 2 A, relay has electrical life at rated load of 100k cycles and mechanical life of 100M cycles (typ).
|
Electronic Timer Relays suit universal applications.Phoenix Contact
Harrisburg, PA 17111 0100
Feb 22, 2008
Able to monitor different time functions without using complicated controllers, Electronic Timer Relays can be adjusted to array of timing settings ranging from milliseconds through several days. Colored LEDs report operating status as well as limit value and relay state. ETD devices equipped with special functions, including star/delta or Wye/Delta and watchdog are also available.
|
 Terminal Block Relays feature 14 mm wide contacts.Phoenix Contact
Harrisburg, PA 17111 0100
Feb 13, 2008
Designed for applications requiring nominal current rating up to 10 A, PLC-RELAY high-current terminal block relays with plug-in SPDT contacts connect to 6 and 14 mm PLC-RELAYS using press fit bridge. Featuring a patented plug-in bridging system which eliminates daisy chain wiring and reduces installation time. Reverse polarity and kick-back diode are included to protect relay and controls. Product is available with either screw or spring terminals.
|
Relays offer switching capacity up to 40 A at 14 Vdc.CIT Relay & Switch: Division of Circuit Interruption Technology, Inc.
Maple Grove, MN 55369
Feb 05, 2008
Automotive A5 Series relays feature contact resistance of less than 50 mW initially, insulation resistance of 100 MW at 500 Vdc, and maximum switching power of 360 W with maximum switching voltage of 75 Vdc, 380 Vac. Dielectric strength is 750 Vrms minimum at sea level and contact-to-contact is 500 Vrms. Operating from -40 to +85°C, sealed, immersion-cleanable relays are available in coil voltage options of 6, 9, 12, 18, and 24 Vdc with coil power choices of 1.6 and 1.9 W.
|
Switching Relay is designed for HVAC and home appliances.Omron Electronics LLC
Schaumburg, IL 60173
Jan 23, 2008
Measuring 19.6 x 15.6 x 15.6 mm, Model G5LA offers switching capacity of 10 A at 250 Vac/24 Vdc and 5 A at 250 Vac/24 Vdc on NO and NC contacts, respectively. With CTI of greater than or equal to 250, it conforms to VDE0435, UL508, and CSA 22.2 standards. Model G5LA-CF comes with Class F coil insulation and UL/CSA approved ambient operating temperature range of -40 to +85°C. Nominal coil power consumption is 360 mW for 5, 9, 12, and 24 Vdc coils and 480 mW for 48 Vdc coil.
|
Relay Modules are suited for railroad engineering.Phoenix Contact
Harrisburg, PA 17111 0100
Jan 14, 2008
Certified according to DIN EN 50155 VDE 0115 Part 200 railroad standard, 6 or 14 mm pluggable PLC RW relay modules operate over ambient temperature range of -40 to + 70°C, and have vibration and shock features. With 1 or 2 changeover contacts, coupling relay modules come equipped with spring cage connectors and can switch loads up to 250 Vac/10 A. Wear-free solid state relays in accordance with EN 50155 for loads up to 110 Vdc/3 A are also available.
|
Dry Reed Relays offer high insulation resistance.Comus International
Clifton, NJ 07012
Jan 10, 2008
Providing high insulation resistance of 1,014 W, MDAS Series mercury-free, dry reed relays come with internal electrostatic shield. Relays are specifically designed for ATE markets, measurement equipment, and test and control systems.
|
(Showing headlines 1 - 20) more ....
|
Latest Products in the News |
Custom Sensors & Technologies (CST) - September 1, 2008 GN Series Solid State Relay
Automation Systems Interconnect Inc. - October 23, 2007 Flexible Low-Cost Bridging of Circuits Expanded to Other Products
Rockwell Automation - August 31, 2006 Rockwell Automation Awarded Best New Product Honor from National Society of Professional Engineers
Rockwell Automation - May 25, 2006 Allen-Bradley Overload Relays with DeviceNet Improve Motor and Load Protection