Quantcast
Search for: Search what?
Jul 24, 2008  
 Newsletters
Subscribe Free to Product News Alerts
  
Receive customized, daily news on the products you want.
Subscribe   View Sample
 Categories
Industrial Market Trends
OnSite WebReviews
Latest New Product News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
Association News
Browse Categories
Browse Companies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Mobile Edition
PR Resources
Licensing
Advertising
How to Write an effective Press Release
Trade Associations
Small Business Support
MEP

Advertisement
Electrical Equipment & Systems -> Electrical Transmission & Switching -> Current Interrupters


Current Interrupters


   Add to Google      PDF icon



(Showing headlines 1 - 20)   more ....
UL-Listed Cable Limiters help maintain system operation.

UL-Listed Cable Limiters help maintain system operation.

Ferraz Shawmut
Newburyport, MA 01950
Mar 27, 2008 CP 600 Cable Limiters isolate damaged conductors that have experienced faults due to short circuit incidents that may have occurred from splicing or insulation breakdowns and then safeguard remaining cables to keep systems operational. Available for cable sizes from 2 AWG to 1,000 kcmil, these 600 Vac products are offered in 7 terminal variations and interrupt faults up to 200 kA to protect low-voltage distribution networks and service entrance cables.

Arc Fault Circuit Interrupter meets 2008 NEC requirements.

Siemens Energy & Automation, Inc.
Elk Grove Village, IL 60007 1902
Jan 14, 2008 Available for use on 120 V, single-phase, 15 and 20 A branch circuits, Combination Type AFCI device is equipped with LED trip indicators that help pinpoint problems that cause device to trip. LEDs located near circuit breaker's handle can distinguish whether trip was caused by arcing faults, arcing to ground, or over current conditions. Compact unit is retrofitable for all Siemens, Murray, I-T-E, and Crouse-Hinds load centers and meter load center combinations.

Receptacle Kits enable compliance with NEC requirements.

Receptacle Kits enable compliance with NEC requirements.

Thomas & Betts Corp.
Memphis, TN 38125
Dec 05, 2007 Designed to help meet NEC 406.8 (B) code requirements for wet locations, Red Dot® Weatherproof While-in-Use Kits come with lockable cover, outlet box, 20 A/125 Vac GFCI receptacle, gasket, plugs, mounting lugs, screws, and sealant. Covers are made of high-impact, UV-resistant polycarbonate or corrosion-resistant, die-cast aluminum. Non-metallic cover can be installed vertically or horizontally, while metallic cover is designed for vertical use only.

GFCI Cord Sets comply with OSHA industrial regulations.

GFCI Cord Sets comply with OSHA industrial regulations.

Tower Mfg. Corp
Providence, RI 02907
Oct 03, 2007 Rainproof and rated for indoor or outdoor use, 125 V/20 A In-Line GFCI Cord Sets come in 2 ft length with straight blade plug and connector as well as 3 and 25 ft lengths with twist lock plug and connector. Units include manual reset feature and 12/3 gauge cord. They are suited for use with industrial equipment, tools, or in wet processing areas.

GFCI Receptacles are designed for harsh environments.

GFCI Receptacles are designed for harsh environments.

Pass & Seymour/Legrand
Syracuse, NY 13221
Aug 27, 2007 DuraShield(TM) employs integral oversized rubber gasket to protect electrical components and seal wall box opening, while rubber curtains let plug blades in and seal out water, dust, and insects. UL-certified GFCI resists corrosion with nickel post-plated mounting strap, and weather-resistant Nylon 66 face provides durability and resists cracking from UV degradation and cold temperatures. SafeLock(TM) Protection shuts off power if there is ground fault and if GFCI is miswired or fails.

Inline GFCI ensures safe power delivery at jobsite.

Inline GFCI ensures safe power delivery at jobsite.

EGS ELECTRICAL GROUP ? APPLETON
Rosemont, IL 60018
Jul 11, 2007 McGill Tri-Tap solves lack of readily available electrical power at jobsites by providing three 15 A, 120 Vac receptacles into which contractors can safely plug in their power tools. Portable unit features 2 ft SJT 12/3 AWG cable with molded NEMA 5-15 plug on line side and attached power block with receptacles on load side. Unit has 4-6 mA trip level and response time of less than .025 sec if it detects electrical leakage that could result in shock or electrocution.

Ground Fault Sensing Module protects outlets on generators.

Ground Fault Sensing Module protects outlets on generators.

Bryant Electric
Milford, CT 06460 2465
Apr 27, 2007 Functioning interdependently with magnetic branch circuit breaker, GFCI module monitors electrical circuit by use of external differential current transformer. No direct load is present at module, and in case of ground fault, load is interrupted by way of circuit breaker utilizing shunt trip coil. Available with automatic or manual safe start reset feature, unit is rated from 1-15 A and is suited for circuit-carrying conductors from 1-3 poles.

GFCI Wiring Devices add safety to construction projects.

Pass & Seymour/Legrand
Syracuse, NY 13221
Dec 15, 2006 Taking advantage of standard commercial pigtailing process, PlugTail(TM) Ground Fault Circuit Interrupters (GFCIs) promote consistent and safe installations for any commercial construction project. Products meet Federal Specification requirements and eliminate exposed terminals for finger safe application. Tail process helps prevent miswiring and offers SafeLock(TM) protection. Line includes Spec and Hospital Grades in nominal, Nightlight, and Tamper-Resistant versions.

GFCI offers 2-stage protection.

GFCI offers 2-stage protection.

Leviton Manufacturing Co., Inc.
Little Neck, NY 11362 2591
Aug 02, 2006 SmartLockPRO(TM) GFCI offers 2-stage protection against ground fault shock hazard. Unit cannot be reset when line and load terminals are mis-wired. In instances of improperly wired load-load reversal, green diagnostic LED indicator turns ON to signal wiring error. Once device is properly re-wired, it can be reset and LED will function as power indicator. If device fails to work properly at any time after it is installed, it cannot be reset, and must be replaced.

GFCI can be used with up to 3 power tools.

GFCI can be used with up to 3 power tools.

EGS Electrical Group
Skokie, IL 60077
Mar 07, 2006 Portable in-line triple-tap Ground Fault Circuit Interrupter (GFCI) detects and shuts off dangerous electrical currents in less than .025 sec. With 4-6 mA trip level, manual reset, and 120 V/15 A rating, it prevents injury or electrocution resulting from water, frayed insulation, or damaged power cords. GFCI offers 2 ft SJT 12/3 AWG cable with NEMA 5-15 plugs on line side and attached molded T-head power block of 3 NEMA 5-15 receptacles on load end.

GFCIs protect against accidental shocks and start-ups.

GFCIs protect against accidental shocks and start-ups.

EGS Electrical Group
Skokie, IL 60077
Sep 16, 2005 Suited for indoor or outdoor jobsites, portable Ground Fault Circuit Interrupters instantly safeguard operators of power tools, drills, washers, and other electrical equipment. UL Listed and CSA Approved, units interrupt electrical power when loads have potentially lethal ground current in excess of 4-6 mA. Contractors can choose from six 15 and 20 A, 120 and 240 V, 60 Hz models, including 11 in. cord set, tri-tap receptacles, in-line GFCIs, and GFCI protected quad box.

Utility Outlet offers external test/reset functions.

Utility Outlet offers external test/reset functions.

Grace Engineered Products, Inc.
Davenport, IA 52807
Aug 31, 2005 ExinPlex® GFCI-protected Inside-Outlet(TM) combines external and internal control panel utility outlet in one assembly. Test and Reset functions are accessible from outside of control panel for maintenance personnel, and unit has clear cover that provides NEMA 12/4 rating when closed. Options include NEMA 4X, NEMA 4X 304 or 316 stainless steel, and circuit breakers. Product carries UL-, CSA-, and CE-certification.

Overcurrent Protector meets GR-1089 Issue 3 requirements.

Overcurrent Protector meets GR-1089 Issue 3 requirements.

Tyco Electronics/Raychem.
Menlo Park, CA 94025-1164
Jul 25, 2005 Suited for communications infrastructure applications, PolySwitch® TSM600-400 interrupts ac power faults to comply with standards such as UL 60950 3rd edition and TIA-968-A. Surface-mount, RoHS-compliant device incorporates 2 matched, low-resistance PPTC components. Each of these 2 resettable overcurrent protection components has typ resistance of 1.2 ohm, and unit has rated hold current of 400 mA at room temperature. Operating temp range is -40° to +85°C.

Ground Fault Receptacle provides added safety for end users.

Ground Fault Receptacle provides added safety for end users.

Bryant Electric
Milford, CT 06460 2465
Jul 07, 2005 When test button is pushed, LED GFR® cycles through complete functional test and will return flashing red LED light if ground fault protection is compromised. It will also provide convenience power at face of receptacle to help prevent unsafe practices while device is out of service. If device is improperly wired, mis-wire protection blocks power at face or downstream loads. Unit meets UL943 surge testing, preventing inoperative power condition that locks out end user.

Illuminated GFCI helps spot use of back-up power.

Illuminated GFCI helps spot use of back-up power.

Pass & Seymour/Legrand
Syracuse, NY 13221
Mar 31, 2005 Illuminated ground fault circuit interrupter (GFCI), resistant to surge, corrosion, and electrical power line noise, has indicator light that remains on when power is available and turns off when wiring device has tripped or power has failed. Product installs with side or screw-pressure-plate backwiring for line and load terminals. To add wiring flexibility and more room in box, 2 backwire holes per termination are provided.

Nightlight/GFCI Receptacle features hospital grade design.

Nightlight/GFCI Receptacle features hospital grade design.

Pass & Seymour/Legrand
Syracuse, NY 13221
Mar 17, 2005 Suited for bathrooms, Hospital Grade Nightlight/GFCI includes sealed nightlight with Lexan® lens that prevents tampering. It also features LED illumination with 20-year life expectancy. Photocell turns nightlight on in dark and off in daylight.

Ground Fault Circuit Interrupter offers decorative design.

Pass & Seymour/Legrand
Syracuse, NY 13221
Mar 31, 2004 Decorator Combination GFCI combines SafeLock™ Protection with decorative addition of single switch, double switch, or LED nightlight. Products offer up-and-down switching and are available in two-switch model. Resistant to surge, corrosion, and electrical power line noise, they install with side or screw-pressure-plate backwiring for line and load terminals. Features include trip indicator light and impact-resistant thermoplastic paddle, face, and backbody.

HVAC Disconnect has compliant ground-fault receptacle.

HVAC Disconnect has compliant ground-fault receptacle.

Cooper Bussmann
Chicago, IL 60706-4792
Jul 23, 2003 Model B222-60NFGF is a 60 A, non-fused ac disconnect pullout with built-in, 110 V ground-fault receptacle for residential and light-commercial applications. Receptacle meets requirement of 210.63 and 210.8 of 2002 NEC®. Rotating design and ample space allow for easy wiring.

GFCI Receptacles meet and exceed UL943 requirements.

GFCI Receptacles meet and exceed UL943 requirements.

Bryant Electric
Milford, CT 06460 2465
May 20, 2003 Ground Fault Circuit Interrupting Duplex Receptacles include 15 and 20 A commercial and hospital grade devices featuring large 50 J, 250 V metal oxide varistor for surge immunity. Noise filtration circuitry prevents false tripping from EMI or RFI, and conformal coated circuit board enhances moisture and corrosion immunity. Receptacles include back and side wiring capability, tri-drive screws, and line-load reversal indication.

GFCIs protect operators of power tools and hand lamps.

GFCIs protect operators of power tools and hand lamps.

McGill Electrical Product Group
Rosemont, IL 60018
Mar 07, 2003 UL-listed Ground Fault Circuit Interrupters protect operators and equipment by interrupting electrical power when loads have potentially lethal ground current in excess of 4–6 milliamps. Manual reset of trip indicator prevents unmonitored equipment start-ups following fault or power outage. Fully portable, plug-in units are offered in 15 and 20 A, 120 and 240 V, 60 Hz ratings. They are suitable for indoor or outdoor use.