Electrical Equipment & Systems
(Showing headlines 3381 - 3400) << 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 ...
|
 DC/DC Converter drives high-current LEDs.Linear Technology Corp.
Milpitas, CA 95035
Sep 22, 2009
Featuring 3-40 V input voltage range, LT3519, 45 V current sense DC/DC converter drives up to ten 100 mA white LEDs from 12 V input. It senses output current at high side of LED, enabling buck, buck-boost, or boost configurations. True Color PWM(TM) dimming delivers constant LED color with ranges of more than 3,000:1. Providing open LED protection, soft-start, and thermal protection, it is available in switching frequency options of 400 kHz, 1 MHz, and 2.2 MHz.
|
 Interlock System is offered with relay expansion modules.Dortronics Systems, Inc.
Sag Harbor, NY 11963
Sep 22, 2009
Dortronic's 4900 Series Intelligent Interlock System lets system designers build on standard mantrap configuration and program additional interlock configurations or operation requirements. It can be customized for unique operational requirements and reprogrammed to accommodate future expansion with additional I/O modules. PLC controller initially handles 33 inputs and 33 outputs and can be expanded to accommodate in excess of 128 inputs and 128 outputs.
|
 DC/DC Converter complies with range of military standards.SynQor
Boxborough, MA 01719 1316
Sep 22, 2009
MilQor Hi-Rel MQFL-28V accepts continuous input voltages of 16-40 V, handles transient input voltages of 5.5-50 V for 1 sec, and operates at efficiencies up to 91%. Providing up to 100 W power, it is available with single output voltages of 3.3, 5, 12, and 28 V, operating in temperatures from -55 to +125°C. Boost-converter stage enables delivery of full power through transients when input falls to as low as 5.5 V. Short circuit and overload protection are featured.
|
DC/DC Converter features 4.2-40 V input voltage range.Linear Technology Corp.
Milpitas, CA 95035
Sep 22, 2009
Model LT3970 step-down switching regulator includes Burst Mode® operation that keeps quiescent current under 2.5 µA in no load standby conditions and keeps output ripple below 5 mVp-p. Unit features 550 mA switch delivering up to 350 mA of continuous output current to voltages as low as 1.21 V. Boost and catch Schottky diodes, oscillator, control, and logic circuitry are also included. Frequency is programmable from 200 kHz to 2.2 MHz.
|
 LED Driver integrates temperature management control.National Semiconductor Corp.
Santa Clara, CA 95051-0695
Sep 21, 2009
Offered in 20-pin thermally enhanced TSSOP, LM3424 drives up to 18 high-brightness LEDs in series with output current above 2 A (typ). It contains all features to regulate currents based on buck, boost, SEPIC, flyback, and buck-boost topologies. Temperature management control, thermal foldback, accelerates and facilitates design of thermal system. It lets lighting designers can program temperature and slope breakpoints within which LEDs operate safely.
|
 Compression Terminals enable application flexibility.FCI/Burndy Products
Manchester, NH 03108
Sep 21, 2009
BREAK-AWAY(TM) HYLUG(TM) promotes field flexibility by allowing installer to convert 2-hole terminal to one-hole terminal to suit application at hand. With slotted second stud, terminals can conform to various bus bar dimensions. Additional flexibility is delivered via narrow tongue design, which allows terminal to fit into tight spaces. Additionally, products accommodate range of conductor combinations: AWG, compact, DLO, flex, and metric.
|
 Level Switch withstands temperatures up to 180°C.Baumer Ltd.
Southington, CT 06489 1534
Sep 21, 2009
Compliant with FDA and EHEDG demands, FlexLevel Switch 4401 detects level of liquids, viscous fluids, and dry media. Blue light on top shows when media is detected, and can be seen even if sensor is mounted on top of tank. Featuring acid-proof stainless steel or PEEK thermoplastic wetted parts, switch is suited for hygienic applications. It can be connected to PC and configured via FlexProgrammer 9701, enabling visual fine-adjustment as well as gating out or zooming in on certain medium.
|
 Sensor IC detects speed and direction of ring magnets.Allegro MicroSystems Inc.
Worcester, MA 01615
Sep 21, 2009
Suited for operation over extended temperatures to 150°C, A1222 includes on single silicon chip: voltage regulator, Hall-voltage generator, small-signal amplifier, chopper stabilization, Schmitt trigger, and short-circuit protected open-collector output that can sink up to 25 mA. On-board regulator allows for operation with supply voltages of 3-24 V. Dynamic offset cancellation reduces residual offset voltage caused by device over-molding, temperature dependencies, and thermal stress.
|
 AC/DC Power Supplies cover power ratings from 25-500 W.SolaHD
Rosemont, IL 60018
Sep 21, 2009
Designed for integration into OEM equipment, GL series single- and multi-switching power supplies feature automatic overvoltage and overload protection, built-in EMI filtering, full power at 50°C, and universal input voltage. They can also be specified with features such as supervisory outputs (5/12 V), wide-adjustable 4th output, and single wire current share. Series comprises 13 models including medical grade units that are certified to UL 2601, CSA 22.2 No. 601.1, and EN 60601-1.
|
 Transfer Switches are UL listed for 30-cycle closing.Russelectric, Inc.
Hingham, MA 02043
Sep 21, 2009
Capable of closing in on and withstanding 30 cycles of fault current, RTS Series Transfer Switches simplify selective coordination of overcurrent/short circuit devices in emergency and backup power systems for healthcare and other mission critical facilities. Switches are available in single- and dual-motor versions in ratings from 100-4,000 A for either open- or closed-transition switching. Bypass/Isolation Switches are also available in load-break and no load-break bypass versions.
|
PV Inverter delivers 97.5% CEC-weighted efficiency.Advanced Energy Industries Inc.
Fort Collins, CO 80525
Sep 21, 2009
Operating at 500 kW, Solaron® 500E enables European commercial and utility-scale PV installations to achieve low levelized cost of energy (LCOE) by increasing energy harvests through controls as well as reducing balance-of-system and operating/maintenance costs. Transformerless design of this grid-tie photovoltaic (PV) inverter eliminates need for step-up transformer and also allows multiple inverter connections to single medium-voltage transformer.
|
 LED Task Light for small spaces.Details
Caledonia, MI 49316
Sep 18, 2009
Able to be mounted via magnet or screws, Mini SOTO(TM) illuminates spaces in freestanding applications that cannot be reached by typical under bin lighting. This 7 x 5/8 x 1 3/8 in. light has 9 ft cord length and uses mercury-free, 4 W LED rated at 120 V, 350 mA max. Clips for cord management are included, and platinum 4799 (metal) finish is standard. Suitable applications include illuminating dark areas beneath steel or wood storage elements.
|
 Emergency Light is visible only when in use.Cooper Lighting
Peachtree City, GA 30269
Sep 18, 2009
Recessed either in ceiling or wall, Sure-Lites Concealed Emergency Light Series is designed for use where architectural appearance is desired. Doors of light open up automatically when power is lost, lighting a path of egress up to 150 ft with two 75 W MR16 halogen lamps. Standard features include self-diagnostics and self-testing to ensure code compliance; self-diagnostic unit will automatically perform tests required by NFPA 101 Life Safety Code every 30 days.
|
Portable Flood Light is rated for hazardous locations.Molex Inc.
Lisle, IL 60532-1682
Sep 18, 2009
With features that directly address safety needs in explosive environments, Woodhead® Hazardous Location Portable Flood Light is CSA-approved and compliant to US and Canadian standards for methane atmospheres. Class 1, Division 1, Group C/D-rated product features dual 300 W halogen lamps that do not heat enclosure above 160°C, rubber (SOW) cordset, and hazardous location plug. Available with NEMA, 1 2, 3R, and 4x enclosures, design facilitates re-lamping and re-wiring.
|
 DC/DC Converters suit broad range of applications.Mornsun America
Hudson, MA 01749
Sep 17, 2009
Featuring 4:1 input range (9-36 Vdc or 18-72 Vdc), URB_LD-15W series of DC/DC converters suit industrial and communications applications. Single output models are fully regulated, with typical load regulation of ±0.5% and line regulation of ±0.2%. Units operate from -40°C to +85°C and come packaged in 1 x 2 in. metal shielded package with industry standard pin-out. Protection circuitry includes over voltage, over current, and short circuit with automatic recovery.
|
 Die-Cast Aluminum Enclosures feature high impact strength.Hammond Manufacturing Co., Inc.
Cheektowaga, NY 14225
Sep 17, 2009
Available in 6 models in sizes ranging from 2.36 x 2.17 x 1.02 in. to 4.63 x 3.54 x 2.01 in., 1550 family enclosures are offered in standard and watertight versions. Watertight units feature separate compressible self-adhesive gasket that, when fitted between lid and base, provides dust and water sealing to IP66. Available with natural or black epoxy powder coated finish, customizable thin-wall enclosures can be drilled and punched to accept cables, switches, and indicators as required.
|
 Compact Automotive LEDs are designed for DRL applications.OSRAM Opto Semiconductor
San Jose, CA 95134
Sep 17, 2009
Measuring 3 x 3 mm², 1 W OSLON MX ECE and 0.5 W OSLON SX ECE provide output of 70-95 and 40-60 lm, respectively and can be operated at temperatures up to 150°C. Energy-efficient LEDs employ ThinGan chip technology, and can be integrated into compact, low-profile designs in daytime running lights (DRL) in front light clusters of mid-range vehicles.
|
Media Distribution Switch supports DVI, USB, and audio.ADDER CORPORATION
Newburyport, MA 01950
Sep 17, 2009
AdderLink INFINITY allows user to pick media elements from computers anywhere on network, and present them from single receiver or broadcast them to as many receivers as desired. Transmitter units connect to computers and receivers connect to screen, speakers, and USB devices. Electronic program guide allows connection to any computer or channel and AdderLink Infinity Management system enables user to control deployed units, manage channels, and apply user/group-based access privileges.
|
DC/DC Converter operates up to junction temp of 150°C.Linear Technology Corp.
Milpitas, CA 95035
Sep 17, 2009
Operating within VIN range of 3.6-33 V, Model LT3972 features internal 4.6 A switch that can deliver up to 3.5 A of continuous output current to voltages as low as 0.79 V. Burst Mode® operation keeps quiescent current under 75 µA, while overvoltage lockout protects against transients as high as 62 V, making IC suited for load dump and cold-crank conditions in automotive applications. Switching frequency is user-programmable from 200 kHz to 2.4 MHz.
|
Power Control Device provides complete remote support.Minicom Advanced Systems Ltd.
Jerusalem 91450 Israel
Sep 17, 2009
Controlled serially via Minicom KVM IP gateway, single-port Power on Cable (PoC) targets IT environments that require complete remote support including BIOS level KVM IP access and remote power control. Power commands are sent only to required device, and power cord design facilitates control of several devices through one management interface. To ensure worldwide compatibility, device is rated from 90-260 Vac, 44-66 Hz up to 10 A.
|
(Showing headlines 3381 - 3400) << 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 ...
|
|
|