Measuring Equipment

Handheld Refractometers feature lightweight design.

Handheld Refractometers feature lightweight design.

Constructed with metal body and weighing from 0.34-1.32 lb, RFH Series determines concentration of aqueous solutions by measuring refractive index using few small drops. Optical instrument features rubber handgrip that blocks hand heat, calibration screen, cushioned rubber eyepiece, and prism mounted in high-impact plastic. Each unit comes with cleaning cloth, suction tube, screwdriver, carrying...

Read More »
Video Measuring Systems are designed to fit on benchtop.

Video Measuring Systems are designed to fit on benchtop.

Available in 3 models, benchtop Sprint(TM) CNC offers XYZ travel from 8 x 8 x 6 in. to 12 x 12 x 6 in. to accommodate variety of parts and provide automated measurement. Along with metrology-grade granite bases and columns, models feature precision motor-driven mechanical bearing stages and 0.5 -µm linear scales. Programmable motorized zoom optics, Hi-Res color cameras, and programmable surface...

Read More »
OL 770-NVS Test & Measurement System for Complete Characterization of NVG Compatible Displays

OL 770-NVS Test & Measurement System for Complete Characterization of NVG Compatible Displays

Optronic Laboratories' OL 770-NVS Test and Measurement System offers a complete solution for measurement of NVG-compatible lighting and displays. The system features multi-channel detection for ultra-fast measurements while exceeding all MIL-L-86762A Appendix B requirements. It is portable and lightweight, and offers a choice of measurement modes. The software is capable of all calculations...

Read More »
In-Line Measurement of Sludge Density Limit Values and Suspended Solids

In-Line Measurement of Sludge Density Limit Values and Suspended Solids

The measurement of solid concentrations or the monitoring of given limit values for sludge or mud density in liquids with ultrasonic can be used everywhere, where optical measurements fail and push to their physical borders. The In-Line measurement of the sludge or mud density can take place in the same measuring armature, as the optical measurement which can be replaced. The user receives...

Read More »
Pressure Systems Adds Absolute Reference Pressure Format with Atmospheric Pressure Compensation to Datalogging Kpsi(TM) Transducers

Pressure Systems Adds Absolute Reference Pressure Format with Atmospheric Pressure Compensation to Datalogging Kpsi(TM) Transducers

Hampton, VA, February 2006 -- Pressure Systems, manufacturer of KPSI(TM) Level and Pressure Transducers, now offers its waterMONITOR submersible datalogging level transducer in an absolute reference pressure format. The sealed reference design simplifies maintenance, since no vent tube or associated desiccant filter is required to guard against moisture incursion. In addition, a specialized...

Read More »
Metrology System measures difficult-to-image features.

Metrology System measures difficult-to-image features.

Multisensor SmartScope® Flash(TM) 200 benchtop dimensional measurement system integrates through-the-lens laser for non-contact surface contouring. Touch probe, laser, and/or micro-probes are available for complete part characterization. It features 200 x 200 x 150 mm XYZ measurement volume and measures parts of different material, malleability, opacity, and color. Motorized 12x AccuCentric®...

Read More »
Flow Limiter allows setting of maximum flow rate.

Flow Limiter allows setting of maximum flow rate.

Welding Gas Flow Limiter allows maximum permissible gas flow levels to be set on flowmeters/regulators employed in cylinder shielding or pipeline gas supply. Once desired maximum flow rate is set, flow rate limiter clamps over flow control knob by tightening set screw thereby preventing increases from desired level. Welders can reduce flow from that predetermined level as application dictates....

Read More »

Measurement System determines roundness and cylindricity.

Able to perform roundness measurement of sub-micron components, Talyrond 295 incorporates diamond-turned, air-bearing spindle and uses glass hemisphere with roundness deviation of less than or equal to 10 nm and individual slope values of less than 2 nm/7.2°. It delivers fully automatic sub-micron analysis of form and geometry. Features include 1.2 nm resolution Talymin 5 gauge head,...

Read More »

Signal Conditioner supports electrolytic tilt sensors.

Designed to interface with single and dual axis electrolytic tilt sensors, Ultra-Dual Model SA40111 delivers 2 channels of RS232 and analog outputs. RS232 output can be read via serial port of PC or by direct interface to microcontroller, while analog output provides interfacing flexibility for most other applications. On-board linearity and temperature correction optimizes performance. Angular...

Read More »

Gas Flow Computer applies Coriolis mass flow technology.

Micro Motion® Model 3711 gas flow computer uses MVD(TM) technology to deliver gas measurement data in compliance with API MPMS Chapter 21.1 and AGA8-92 world standards. It combines flow computer with user's choice of Coriolis meters for flow measurement of pure gas or gas mixture with uncertainty of less than 0.5%. With features such as digital flow analysis and PID flow control, unit suits...

Read More »
Tekna Manufacturing LLC Announces NFPA 99 Compliant Model 7200 Multiplace Chamber
Sponsored

Tekna Manufacturing LLC Announces NFPA 99 Compliant Model 7200 Multiplace Chamber

Tekna is a leader in Monoplace and Multiplace Hyperbaric Chambers for Hyperbaric Oxygen Therapy (HBOT), offering products that set the standard for quality and innovation. Our new 7200 series of multiplace chambers is a state-of-the-art system that integrates advanced engineering with a plethora of features and options making it the industry's premier HBOT system. To learn more, see our video.

Read More »

All Topics