Calex

DC/DC Converter delivers 25-30 W of output power.
Electrical Equipment & Systems

DC/DC Converter delivers 25-30 W of output power.

Offered in standard 2 x 1 in. package with 18-36 and 36-72 Vdc input ranges, TMJ Series features output voltage range of 2.5-15 Vdc and operating ambient temperature range of -40 to 50°C with no de-rating. Low output voltages of 2.5, 3.3, 5, and 5.1 utilize synchronous rectification to achieve efficiencies as high as 88%. CSA 60950 approved unit is encapsulated with thermally conductive potting...

Read More »
Triple Output DC/DC Converters provide up to 75 W of power.
Electrical Equipment & Systems

Triple Output DC/DC Converters provide up to 75 W of power.

HE Series DC/DC converters provide primary output of either 3.3 or 5 Vdc, rated at 15 and 20 A, respectively, and auxiliary outputs of either ±12 or ±15 Vdc, rated at ±2 A. Housed in standard -½ brick case, all models are fully encapsulated for use in harsh industrial and military COTS applications and feature 2:1 input range, either 18-36 or 36-75 Vdc. Features include output voltage trim...

Read More »
Signal Conditioner is DIN rail mountable.
Electronic Components & Devices

Signal Conditioner is DIN rail mountable.

Measuring 3.78 x 1.06 x 1.65 in., Model 6255 strain gage to PLC frequency input DC power module is designed for load cell, strain gage, or single ended analog amplification and filtering. It has 0-50 mV input range, precision instrumentation amplifier, 100-10,100 Hz filtered output, and built-in 10 V excitation supply that can drive 350 W bridge. Connections are made via screw clamp terminal...

Read More »
Chassis Mount DC/DC Converters suit harsh industrial/COTS applications.
Electrical Equipment & Systems

Chassis Mount DC/DC Converters suit harsh industrial/COTS applications.

Available in case with dimensions of 4.3 x 3.2 x 1 in., 150 W HCM Series have input voltage range from 9-36 Vdc and 18-75 Vdc, and output voltages of 3.3, 5, 12, 15 and 24 Vdc. RoHS compliant units in case have operating temperature range between -40°C to +100°C, MTBF of over 1M hr, and weigh 11.4 oz. Electrical features include volt-seconds clamp, over voltage protection, pulse by pulse...

Read More »
Signal Conditioners provide 3-way signal isolation.
Electronic Components & Devices

Signal Conditioners provide 3-way signal isolation.

Housed in plastic case measuring 4.3 x 0.89 x 2.9 in., 8940 Series thermocouple to analog 0-10 V signal conditioners are designed for use with 100, 500, and 1,000 W platinum RTDs with temperature range of -50 to 450°C and with 2 or 3 wire RTD configurations. Input is isolated from output and both are isolated from supply voltage. Employing linearization and 3 wire compensation, all models...

Read More »
Signal Conditioners tolerate temperatures to 500°C.
Electronic Components & Devices

Signal Conditioners tolerate temperatures to 500°C.

Providing output frequency of 100 Hz at 0°C to 5,100 Hz at 500°C, with 12 bit resolution, Model 8511 and 8512 thermocouple to frequency signal conditioners are used with Type J and Type K thermocouples, respectively. They operate on common 24 V, 7 mA PLC high-speed counter input and utilize linearization and cold junction compensation. Suited for remote temperature monitoring applications,...

Read More »
DC Input Filter features water washable non-conductive case.
Electronic Components & Devices

DC Input Filter features water washable non-conductive case.

Designed to be used in between power source and DC/DC converter, EFIL-100-10 accepts max input voltage of 100 Vdc and max input frequency of 100 Hz, offering isolated input to output at 1,000 Vdc. Single unit can be used as front end for multiple DC/DC converters, with total input current of 10 Adc max. Insertion loss is 31 dB in differential mode and 28 dB in common mode. Available with/without...

Read More »
Linear Power Supply offers 3 highly regulated outputs.
Electrical Equipment & Systems

Linear Power Supply offers 3 highly regulated outputs.

Supplied in 3.50 x 2.5 x 1.56 in. package, 3.15.1000 provides low-noise/ripple (2 mV RMS), ±0.20% line and load regulated +5 and ±15 V outputs for 8 W total output power. Epoxy potted construction suits use in sensitive analog circuitry applications utilizing op-amps, function modules, and data conversion circuits. While 5 V output provides up to 1 A, ±15 V outputs provide up to ±100 mA....

Read More »
Signal Conditioner accommodates 4 load cells/strain gages.
Electronic Components & Devices

Signal Conditioner accommodates 4 load cells/strain gages.

Designed for load cell, strain gage, or single-ended use, DC-powered Model 4850 offers 4 individual amplifier channels. Each channel contains precision instrumentation amplifier with individual Zero and Span adjustments as well as filtered 0-10 Vdc output. Input range of 0-30 mV is compatible with most strain gage-based load cell or pressure transducer outputs. Built-in excitation supply, capable...

Read More »
DC/DC Converters provide 28 and 48 Vdc output.
Electrical Equipment & Systems

DC/DC Converters provide 28 and 48 Vdc output.

Housed in cast case rated for -40 to +10°C and potted with thermally conductive compound, 200 Watt TH Series provides true 9-36 V input range, which accommodates 12 V battery, 24 V industrial, and 28 V COTS military applications. Units offer pulse-by-pulse current limiting, over-temperature protection, and auto softstart. Load Regulation and Line Regulation is 0.02% and 0.01% respectively, while...