Moore Industries International, Inc.

Communication Systems & Equipment

Fieldbus System powers 16 devices in hazardous environments.

Suited for DCS installations, ROUTE-MASTER(TM) Series 100 System features intrinsically-safe, isolated power supply with 350 mA per segment, which can drive up to 16 devices over cable segments up to 1,900 m long. Product utilizes split architecture design with device coupler mounted close to group of devices anywhere in Class I Division 1 Group C or D environments. Able to power FOUNDATION...

Read More »
Agricultural & Farming Products

Chlorination Controller suits water/wastewater applications.

Model 555 Â-¼ DIN Controller provides solution for various chlorination and de-chlorination processes. Front panel is rated NEMA 4X, menu prompts are in plain English, and alphanumeric display is readable in all light conditions. With isolated 4-20 mA or 0-20 mA outputs for control or retransmission to analog system, unit offers alarm trip outputs for flow rate, chlorine residual, dosage...

Read More »
Concentrator System converts HART signals to MODBUS RTU.
Electrical Equipment & Systems

Concentrator System converts HART signals to MODBUS RTU.

HCS HART Concentrator System converts HART digital signal to RS-485 MODBUS RTU communication protocol, permitting up to 16 smart HART-capable transmitters and valves to interface directly with MODBUS-based monitoring and control systems. Users can monitor primary and non-primary process variables from various devices, and MODBUS system can monitor HART instrument diagnostics using Field Device...

Read More »
Limit Alarm Trips offer 20-bit input resolution.
Safety & Security Equipment

Limit Alarm Trips offer 20-bit input resolution.

SPAÂ-² Current/Voltage and RTD/Thermocouple Limit Alarm Trips provide on/off control, warn of trouble, and enable emergency shutdown. Units offer 2 or 4 independent and individually configurable alarm relay outputs as well as user-selectable high/low limit. Using on-board controls or PC Configuration Software, each alarm trip relay may be programmed as high/low limit process alarm,...

Read More »
Process Control System offers MODBUS RTU communications.
Controls & Controllers

Process Control System offers MODBUS RTU communications.

NET ConcentratorÂ-® System Process Control and Distributed I/O Network is available with RS-485 communication capabilities. This enables system to use twisted wire pair, Ethernet, wireless (RF), fiber, and telephone modem data links to send monitoring and control signals over long-distance and in hazardous environments. System features 20-bit measurement resolution, signal conditioning...

Read More »
Electrical Equipment & Systems

Temperature and Signal Transmitter is PC programmable.

TMZ MODBUS Transmitter accepts direct signal from sensors and analog devices including RTD, thermocouple, ohms, mV, current, voltage, and potentiometer. Unit converts inputs to standard MODBUS RTU protocol ready for direct interface with MODBUS-based monitoring and control systems. Housed in rugged, metal, RFI resistant housing, TMZ is isolated and protected against effects of ground loops, plant...

Read More »
Communication Module provides wireless connectivity.
Communication Systems & Equipment

Communication Module provides wireless connectivity.

Wireless Link Module (WLM) provides connectivity between remote field sites. Bi-directional, spread spectrum module employs Intelligent Spectrum Frequency Hopping technology and 32-bit CRC error correction. Available models support Ethernet or serial communications and operate at FCC license-free frequency ranges of 902-928 MHz or 2.4-2.483 GHz. It is suited for use with NET ConcentratorÂ-®...

Read More »
Agricultural & Farming Products

Process Control/Network withstands demanding applications.

NET ConcentratorÂ-® System provides 20-bit measurement resolution and data rates up to 100 megabits/sec. Using 10/100Base-T Ethernet or MODBUS RTU network, it connects legacy and distributed field devices to DCS, PLC, or PC-based strategy. DIN rail mount process control and distributed I/O network operates in peer-to-peer and peer-to-host configurations. Data logging capabilities allow up to...

Read More »
Electrical Equipment & Systems

Temperature Transmitters/Alarm Trips are PC-programmable.

Universal products offer 20-bit input resolution, complete signal isolation, RFI/EMI protection, and metal housings that snap onto DIN-style rails. Model CPA Limit Alarm Trip and model CPT Temperature Transmitter and Signal Isolator/Converter accept direct signal input from sensors and analog devices. Former provides 1 or 2 alarm relay outputs, while latter provides isolated and linear current or...

Read More »