GLI International, Inc.
Milwaukee, WI 53224
Share:
Transmitters come in NEMA 4X package.
PRO Series line of transmitters measure pH, ORP, contacting and electrodeless conductivity, dissolved oxygen, or flow. All transmitters have panel, wall, pipe, or integral sensor mount configurations in compact NEMA 4X package. Multiple languages with simple menu-guided operation are also standard.
Read More »Conductivity Sensors have electrodeless design.
Model 3700E-Series eliminates polarization and electrode coating problems that commonly affect contacting, electrode-type conductivity sensors. Only one wetted material contacts process media. Body materials are polypropylene, PVDF, PEEK(R), or PFA Teflon(R). Sensors are available in convertible or sanitary mounting styles. They can measure solutions with conductivity as high as 2,000,000...
Read More »Conductivity Tester suits panel, surface, or pipe mounting.
Model E53 Electrodeless Conductivity Analyzer measures conductivity, total dissolved solids, and concentration in percent. Built-in chemical tables facilitate concentration configuration in various concentration ranges, and users can create custom concentration tables with up to 10 data points. Analyzer offers backlit, graphic LCD, multiple language operation, RS-232 output, and epoxy-coated...
Read More »pH/ORP Sensors use differential electrode technology.
pHD(TM) electrode sensors use 3 measuring electrodes. Process and reference electrodes measure pH differentially, with respect to third ground electrode, reducing reference junction fouling and minimizing ground loops. Preamplifier boosts electrodes' mV signals for transmission up to 3,000 ft. PEEK(R) and Ryton(R) bodies provide chemical resistance in aggressive process solutions. Convertible,...
Read More »Chlorine Monitor accurately measures free or total chlorine.
AccuChlor2 uses EPA-approved amperometric measurement technique. Measuring cell provides stable and repeatable measurements from extremely low ppm ranges to as high as 60 ppm. Monitor uses non-toxic, non-hazardous distilled white vinegar for process pH adjustment. Unit is suitable for use in municipal and industrial water and wastewater treatment.
Read More »Three Sensors provide dissolved oxygen measurement.
Model 5600 uses 3-electrode polarographic Ross Cell technology. Model 5500 uses 3-electrode Clark Cell technology to provide more accurate and stable measurement than 2-electrode technologies. Model 5040 self-cleaning sensor excels in processes that have high concentrations of grease and/or oil.
Read More »Analyzer provides suspended solids measurements.
Model 7110 continuous on-line analyzer measures and controls suspended solids concentration or turbidity. Measurements can be displayed in ppm, mg/l, g/l, %, NTU, or FTU, depending on sensor model being used. Analyzer includes menu-guided operation and user-friendly interface. Series 7500 Sensors use multi-beam optical measurement technique which compensates for sensor fouling and aging of...
Read More »Flow Analyzer features 4 measuring channels.
Model F53 measures liquid flow rates and totalized volume for up to 4 sensors. It has 2 isolated analog outputs (selectable 0-20 or 4-20 mA) and 2 pulsed contact closure outputs for remote counting or pumping. Four relays can be independently set to function for control, dual-alarms or diagnostic status. Housed in epoxy-coated, metal 1/2 DIN, NEMA 4X rated enclosure, Model F53 is designed for...
Read More »ph/ORP Controllers support most applications.
Family consists of Series 63, with true predictive and reactive diagnostics; Series 53, full-featured analyzer; and panel-mounted Series 33, designed for OEMs. All versions accept differential sensors, conventional electrode pairs, and combination electrodes. Series 63 and 53 simultaneously display pH and process temperature on backlit LCDs. Options include multiple analog outputs, relays, and...
Read More »Chlorine Monitor finds free, residual or total chlorine.
AccuChlor system uses EPA approved amperometric measurement to check chlorine in low ppm ranges. It uses ordinary 5% food grade distilled white vinegar for pH adjustment. Readily available, non-toxic, non-hazardous vinegar prevents fouling by cleaning sensor's flow cell. Applications include municipal and industrial water and wastewater plants, food and beverage processing, pharmaceutical...
Read More »Transmitters come in NEMA 4X package.
PRO Series line of transmitters measure pH, ORP, contacting and electrodeless conductivity, dissolved oxygen, or flow. All transmitters have panel, wall, pipe, or integral sensor mount configurations in compact NEMA 4X package. Multiple languages with simple menu-guided operation are also standard.
Read More »Conductivity Sensors have electrodeless design.
Model 3700E-Series eliminates polarization and electrode coating problems that commonly affect contacting, electrode-type conductivity sensors. Only one wetted material contacts process media. Body materials are polypropylene, PVDF, PEEK(R), or PFA Teflon(R). Sensors are available in convertible or sanitary mounting styles. They can measure solutions with conductivity as high as 2,000,000...
Read More »Conductivity Tester suits panel, surface, or pipe mounting.
Model E53 Electrodeless Conductivity Analyzer measures conductivity, total dissolved solids, and concentration in percent. Built-in chemical tables facilitate concentration configuration in various concentration ranges, and users can create custom concentration tables with up to 10 data points. Analyzer offers backlit, graphic LCD, multiple language operation, RS-232 output, and epoxy-coated...
Read More »pH/ORP Sensors use differential electrode technology.
pHD(TM) electrode sensors use 3 measuring electrodes. Process and reference electrodes measure pH differentially, with respect to third ground electrode, reducing reference junction fouling and minimizing ground loops. Preamplifier boosts electrodes' mV signals for transmission up to 3,000 ft. PEEK(R) and Ryton(R) bodies provide chemical resistance in aggressive process solutions. Convertible,...
Read More »Chlorine Monitor accurately measures free or total chlorine.
AccuChlor2 uses EPA-approved amperometric measurement technique. Measuring cell provides stable and repeatable measurements from extremely low ppm ranges to as high as 60 ppm. Monitor uses non-toxic, non-hazardous distilled white vinegar for process pH adjustment. Unit is suitable for use in municipal and industrial water and wastewater treatment.
Read More »Three Sensors provide dissolved oxygen measurement.
Model 5600 uses 3-electrode polarographic Ross Cell technology. Model 5500 uses 3-electrode Clark Cell technology to provide more accurate and stable measurement than 2-electrode technologies. Model 5040 self-cleaning sensor excels in processes that have high concentrations of grease and/or oil.
Read More »Analyzer provides suspended solids measurements.
Model 7110 continuous on-line analyzer measures and controls suspended solids concentration or turbidity. Measurements can be displayed in ppm, mg/l, g/l, %, NTU, or FTU, depending on sensor model being used. Analyzer includes menu-guided operation and user-friendly interface. Series 7500 Sensors use multi-beam optical measurement technique which compensates for sensor fouling and aging of...
Read More »Flow Analyzer features 4 measuring channels.
Model F53 measures liquid flow rates and totalized volume for up to 4 sensors. It has 2 isolated analog outputs (selectable 0-20 or 4-20 mA) and 2 pulsed contact closure outputs for remote counting or pumping. Four relays can be independently set to function for control, dual-alarms or diagnostic status. Housed in epoxy-coated, metal 1/2 DIN, NEMA 4X rated enclosure, Model F53 is designed for...
Read More »ph/ORP Controllers support most applications.
Family consists of Series 63, with true predictive and reactive diagnostics; Series 53, full-featured analyzer; and panel-mounted Series 33, designed for OEMs. All versions accept differential sensors, conventional electrode pairs, and combination electrodes. Series 63 and 53 simultaneously display pH and process temperature on backlit LCDs. Options include multiple analog outputs, relays, and...
Read More »Chlorine Monitor finds free, residual or total chlorine.
AccuChlor system uses EPA approved amperometric measurement to check chlorine in low ppm ranges. It uses ordinary 5% food grade distilled white vinegar for pH adjustment. Readily available, non-toxic, non-hazardous vinegar prevents fouling by cleaning sensor's flow cell. Applications include municipal and industrial water and wastewater plants, food and beverage processing, pharmaceutical...
Read More »