 Relay Output Module features USB/104 form-factor.ACCES I/O Products, Inc.
San Diego, CA 92121 1506
May 23, 2008
Measuring 3.550 x 3.775 in., Model USB-IDIO-16 features 16 individually optically isolated inputs and 16 fully protected, solid-state FET outputs capable of switching from 5-34 Vdc at up to 2 A. Unit is compatible with USB 1.1 and USB 2.0 ports and offers hot-plug functionality for quick connect/disconnect. Suited for industrial environments, module includes jumper-selectable filtering per input channel, and polarity insensitive AC/DC inputs that accept up to 31 Vdc or AC rms.
|
 Sensor Interface Module includes noise filtering.Phidgets, Inc.
Calgary, AB T2M3R7 Canada
May 23, 2008
Providing 8 analog inputs, 8 digital inputs, and 8 digital outputs, 1018 PhidgetInterfaceKit 8/8/8 includes 2-stage digital input filter, which rejects noise of frequency higher than 1 kHz, eliminating false triggering. Analog inputs measure continuous quantities such as temperature, humidity, position, and pressure. Digital inputs convey state of push buttons, limit switches, and relays, while digital outputs drive LEDs, solid-state relays, and transistors.
|
 Ethernet I/O Modules feature P2P functionality.Advantech Automation Corp.
Cincinnati, OH 45240
May 23, 2008
With peer-to-peer functionality provided in firmware, ADAM-6000 distributed Ethernet I/O modules can actively update input channel status to specific output channels. Data will transfer automatically, with no extra controller or programming needed. GCL software utility, also included, adds control logic between input and output, and can create equivalent instructions to simple ladder logic instructions on PLC's. It also supports flexible cascade function locally or over Ethernet network.
|
 I/O Unit acquires data up to 250 kHz at 16-bit resolution.Audon Electronics
Nottingham NG9 4AT United Kingdom
May 19, 2008
Model USB-AD16F multifunction I/O unit features 16-channel, 16 opto-isolated analogue inputs, 2 analogue outputs, 4 digital inputs (programmable input ranges of ±10, ±5, ±2, and ±1 V), and 4 digital outputs. All I/O are presented via two 37-way D-type sockets, one analogue and one digital. Suited for noise and vibration measurements and impact testing, USB based product is compatible with MAL series of signal conditioning modules for connection of thermocouples and strain gauges.
|
HART Analog Input Module is TUV SIL 3 certified.Siemens Energy & Automation, Inc.
Alpharetta, GA 30005
May 19, 2008
Available for use with SIMATIC ET 200M I/O and PCS 7F process safety systems, failsafe SIMATIC® SM 336 supports single, dual, and triple redundancy architectures. HART communications and diagnostics are set up from central computer with SIMATIC PDM software, eliminating need for field configuration. All diagnostic information from devices is readily available on central computer, and there are 6 isolated HART analog inputs between channels and its backplane bus.
|
USB DAQ Device features BNC inputs.Measurement Computing Corp.
Norton, MA 02766
May 15, 2008
Model USB-1616HS-BNC is 1 MS/sec, 16-bit multifunction USB DAQ device with 16 BNC differential analog inputs. It offers low-latency, highly deterministic control output mode that operates independently of PC, enabling digital, analog, and timer outputs to respond to analog, digital, and counter inputs as fast as 2 µs. Featuring synchronous and concurrent voltage input, waveform output, counter input, quadrature encoder input, and digital I/O, device also offers extensive trigger options.
|
Digital Output Boards expand Cube and chassis capacity.United Electronic Industries
Canton, MA 02021
May 12, 2008
Along with 32 channels of digital output, Guardian DNA/DNR-DIO-432 and -433 offer up to 600 mA per-channel continuous current with output voltage drop of less than 550 mV. DNA models are designed for use with Ethernet Cube products, and DNR models are designed for 12-slot rack-mounted RACKtangle(TM) I/O chassis. Respectively, outputs for -432 and -433 versions are configured as current sources and sinks. Max throughput rate is 1 kS/s, and input mode enables channel diagnostics.
|
Analog Input Module has 0.001°C temperature resolution.Omron Electronics LLC
Schaumburg, IL 60173
May 06, 2008
Intended for CJ-Series PLCs, Model CJ1W-PH41U 4-point analog input module offers 18-bit resolution, and accepts 28 different types of inputs, simplifying inventory control and maintenance. Present Value can be scaled in any industrial units and is automatically calculated, and rate-of-change calculation can be set from 1-16 sec, allowing even any small rate of change to be detected. Unit features built-in alarm hysteresis, mean value processing, and alarm on-delay setting.
|
FPGA Mezzanine Card is based on VITA 57.1 standard.VMETRO, Inc
Houston, TX 77077
Apr 30, 2008
Available in air- and conduction-cooled rugged versions, Model ADC510 integrates two 500 MHz ADC devices, each supporting sampling rate up to 500 MSps and providing 12-bits of digital output. ADC device interfaces are routed to FMC connector to enable FPGA on baseboard to directly control and receive data. Choice of sample clock sources include onboard source that supports sampling rates of 300, 320, 400, and 500 MSPS as well as ability to utilize external sample clock.
|
 Expansion I/O Modules offer 4 or 8 channels.Siemens Energy & Automation, Inc.
Alpharetta, GA 30005
Apr 29, 2008
Part of SIMATIC® S7-200 micro PLC line, EM231 8-channel analog input module accepts unipolar 0-10 Vdc, 0-5 Vdc, 0-20 mA, and bi-polar ±5 Vdc and ±2.5 Vdc input signals, while 4-channel EM232 analog output module supports 0-10 Vdc and 0-20 mA output signals. Eight-channel EM231 TC temperature input module accommodates 7 thermocouple sensor types and ±80 mV input signals, while 4-channel EM231 supports 8 RTD sensor types and 150, 300, and 600 W resistance inputs.
|
 Micro PLC utilizes universal analog input module.IDEC Corporation
Sunnyvale, CA 94089-2209
Apr 29, 2008
Expanding capabilities of MicroSmart Pentra micro PLC, 4-point Universal Input Module accepts most analog signals including 0-10 V, 4-20 mA, thermocouples, RTD, and Nickel. Snapped to side of PLC, module offers 16-bit resolution and 0.2% accuracy. Programmable logic control features double word and floating math, Modbus RTU/ASCII, Modbus TCP/IP, upgradeable firmware, embedded 100 kHz I/O, and up to 7 communication ports.
|
FPGA Processor supports FMC/VITA 57 standard.VMETRO, Inc
Houston, TX 77077
Apr 21, 2008
Model FPE650 integrates 4 fully inter-connected user programmable Xilinx® Virtex®-5 FPGAs with 2 FMC I/O sites and VPX high-speed serial backplane connectivity, allowing I/O and processing capabilities in single 6U slot. Available in air- and conduction-cooled rugged versions, it is designed to tackle demanding digital signal processing applications such as Electronic Counter Measures (ECM), Signal Intelligence (SIGINT), and Electro-Optics (EO).
|
 PC/104-Plus Card targets ARINC 429 and 717 applications.Ballard Technology
Everett, WA 98201
Apr 17, 2008
Offering up to 16 ARINC 429 channels and 4 ARINC 717 channels on PC/104-Plus platform, Model PM429-2 features universal API library, which allows developers to program software on Ethernet or PCI card and import it to PM429-2. Card provides IRIG timer and 16 I/O avionics discrete I/O signals, which can be used as general-purpose I/O or as trigger inputs and sync outputs for protocol functions. Discrete output circuits can sink up to 200 mA and withstand up to 35 Vdc applied to pin.
|
 AS-Interface Modules offer output-specific diagnostics.Pepperl+Fuchs
Twinsburg, OH 44087
Apr 15, 2008
Available in 6 models, G12 Series features SPEEDCON M12 connectors and single stainless steel mounting base that supports short and long style housings as well as various I/O mixes. Output-specific diagnostics allow maintenance personnel to quickly identify and correct problems, while machined, gold-plated contacts provide corrosion resistance. Integrated DIN clip on mounting base eliminates need for users to choose ahead of time how G12 will be mounted.
|
 PMC Modules interface I/O signals to Virtex-5 FPGA.Acromag, Inc.
Wixom, MI 48393 7037
Apr 14, 2008
PMC-VSX modules feature DSP-optimized Xilinx® Virtex(TM)-5 FPGA, reconfigurable for optimal I/O processing and user-developed algorithmic computation. Banks of DDR2 DRAM accelerate data transfer in and out of FPGA, and dual-port SRAM promotes DMA transfer to PCI bus. PCI-X interface ensures bandwidth availability, and assorted plug-in I/O extension modules offer analog and digital I/O signal flexibility. Extended temperature (-40 to 85°C) and conduction-cooled models are available.
|
 I/O Module complies with IEEE-Std 1149.x.GOEPEL electronics LLC
Austin, TX 78759
Apr 10, 2008
Controlled via standard Test Access Port, CION Module(TM)/FXT114S provides total of 114 parallel I/O channels. Unit's 64 single-ended test channels are independently controllable as input/output/tristate. I/O voltage can be programmed from 1.8-5.0 V in groups of 32 channels. In addition to single-ended channels, module features 50 differential channels, 25 configured as inputs and 25 configured as outputs. UNSTRESS feature protects unit under test against damage in case of shorts.
|
 Analog Input Modules support high common mode function.Advantech Automation Corp.
Cincinnati, OH 45240
Apr 01, 2008
Available with channel-to-channel differential voltages up to 200 Vdc, Models ADAM-5017P and ADAM-5018P are suited for battery or power transducer/transmitter measurements. Model ADAM-5017P has 8 different independent configuration channels, wide uni-polar or bi-polar input range, and supports power reverse. Model ADAM-5018P is thermocouple input module which supports 7 input ranges and types (J,K,T,E,R,S,B), and filters functions to remove any unreasonable range.
|
Digital Input Boards offer analog input capability.United Electronic Industries
Canton, MA 02021
Mar 28, 2008
Compatible with Cube and RACKtangle I/O chassis, Guardian Series(TM) DNA-DIO-448 and DNR-DIO-448 read all 48 bits at sustained rates in excess of 1 kS/sec. Input switching levels are software selectable from 0-28 Vdc with 25 mV resolution. Diagnostic input mode measures analog voltage at each input, allowing detection of short and open circuits as well as identifying marginal or failing drive circuitry. Analog input capability also offers installation, diagnostic, and data acquisition tool.
|
Ethernet-Based I/O Module is fault-tolerant.SIXNET
Clifton Park, NY 12065 0767
Mar 26, 2008
With web-based I/O configuration and monitoring, self-calibrating analog I/O, and OEM customizable components/labeling, EtherTRAK-2 features RS483 and USB Ethernet ports with MAC and IP addresses, allowing 2 module connections to independent networks. ISO9001, CUL, UL DNV, CE, FCC, and RoHS rated module has operating temperature range of -40 to 75°C. Compact enclosure snap-locks into wiring base, and hot-swap capability minimizes downtime.
|
 Programmable Logic Device offers extended functionality.Sprint Electric Ltd
Arundel East Susse BN18 0BE United Kingdom
Mar 21, 2008
Used by system integrators, Programmable Logic Arithmetic unit (PLA) offers functionalities for diverse applications and motion tasks. Stand-alone unit can compliment and enhance any analog or digital drives system. Via range of configurable I/O to internal application blocks, PLA enables user to define control strategy to meet unique demands of process or application at hand. Connectivity is fostered by RS232 port and field bus communication card compatibility.
|