Test & Measuring Instruments
(Showing headlines 7141 - 7160) << 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 ...
|
 Data Logger records temperature and humidity.Omega Engineering, Inc.
Stamford, CT 06907
Apr 29, 2008
Equipped with 8-button, lock-capable keypad and backlit LCD, wall-mountable Model OM-CP-RHTEMP 2000 simultaneously displays remote readings of environmental parameters. On-screen data includes Min, Max, and Avg statistics for both channels; Start, Stop, and Recording Rate status; calibration information; and display options, including channels shown, units, and text size. Logger will retain recorded data even when AC and battery power are lost.
|
 Micro PLC utilizes universal analog input module.IDEC Corporation
Sunnyvale, CA 94089-2209
Apr 29, 2008
Expanding capabilities of MicroSmart Pentra micro PLC, 4-point Universal Input Module accepts most analog signals including 0-10 V, 4-20 mA, thermocouples, RTD, and Nickel. Snapped to side of PLC, module offers 16-bit resolution and 0.2% accuracy. Programmable logic control features double word and floating math, Modbus RTU/ASCII, Modbus TCP/IP, upgradeable firmware, embedded 100 kHz I/O, and up to 7 communication ports.
|
 FTIR Spectrometers enable on-site lubrication analysis.A2 Technologies, LLC
Danbury, CT 06810
Apr 29, 2008
Designed for lubrication analysis in various power industry systems, PAL instruments quantify water levels from 50-5,000 ppm in oils with accuracy of better than 5%. Products utilize Fourier Transform Infrared (FTIR) method, which requires no hazardous reagents. In addition to measuring water level, systems immediately yield amount of oxidation and nitration byproducts present as well as amount of anti-oxidation, anti-wear, and extreme pressure additives that remain in lubricant.
|
 Optical Loss Tester stores up to 50 records.GAO Embedded Inc.
Toronto 12345 Canada
Apr 29, 2008
GAO802 Optical Loss Tester features dual-wavelength stable laser source and high-contrast backlit display. Compact device includes automatic power off after 6 min idle and performs auto wavelength identification and absolute power test. It offers working wavelengths of 1,310 and 1,550 nm, return loss of 0-50 dB with accuracy of ±1.5 dB, and optical power of +3 to -50 dBm with accuracy of ±5%. With working temperature of 0-40°C, unit is powered by NiMH chargeable battery.
|
Door Activation Sensor offer programmable operation.Pepperl + Fuchs, Inc.
Twinsburg, OH 44087 2245
Apr 29, 2008
Employing swiveling optics to optimize threshold coverage, FLT-D triggers opening of automatic sliding doors when it detects approaching people and objects. Programming options include sensing area size, sensitivity to targets, synchronization to other FLT-D units, and frequency of automatic teaches. Able to monitor up to 20 sensing field segments by IR array, this IR photoelectric sensor learns and periodically re-learns its static environment automatically.
|
 Optical Power Multi Meter offers ±5% accuracy.GAO Embedded Inc.
Toronto 12345 Canada
Apr 29, 2008
With 800-1,600 nm wavelength range, Model GAO801 Optical Power Multi Meter performs absolute power test in units of dBm or W, relative power test in units of dB, as well as loop and auto bi-directional test. InGaAs detector features -45 to +25 dBm optical power test range, 0.1% linearity display, and 0.01 dBm logarithm display. Powered by 9 V/160 mAh battery, it has memory capacity of 50 data items, high contrast backlit display, and adapters supporting FC, ST, and SC ports.
|
 Infrared Pyrometers measure temperature range down to 482°F.Process Sensors Corp
Franklin Lakes, NJ 07417
Apr 29, 2008
Utilizing short wavelength that minimizes effects due to emissivity changes, Sirius Series pyrometers have adjustable focus and high resolution field of view, providing small spot sizes. Units offer 4-20 mA analog and RS232 or RS485 digital outputs, as well as feature PSCWin software that displays real-time graphs. Sirius SS09 with spectral range of .67-1.1 µm has temperature range of 550-1,800°C, while Model SI16 with spectral response of 1.45-1.8 µm measures temperature from 250-1,800°C.
|
Mini Datalogger stores over 2,000,000 measurement parameters.MSR Electronics GmbH
Henggart CH-8444 Switzerland
Apr 29, 2008
Measuring 52 mm long, thumb-sized MSR 145 can capture and save range of different physical measurements simultaneously. Unit includes temperature sensor, humidity sensor with integrated thermometer, pressure sensor with integrated thermometer, and 3-axis acceleration and position sensor. Integrated clock permits data from multiple MSR 145 units to be merged synchronously into single data record, while USB interface enables measurement evaluations to be presented on PC in graphic form.
|
WiMAX Testing Kit offers choice of 3 frequencies.Berkeley Varitronics Systems
Metuchen, NJ 08840-1217
Apr 29, 2008
Helping carriers optimize signals, WiMAX Testing Kit is suitable for 700 MHz, 2.5 GHz, and 3.5 GHz networks. Gator(TM) Class A stimulus transmitter provides CW radio beacon for proposed tower site, while YellowFrog(TM) 2 power meter validates RF output levels at transmitter antenna end. With Coyote(TM) dual-band modular receiver, users can perform drive-studies, walk-about, or in-building studies. Geo-coded, drive-study data can then be post-processed using Forecaster(TM) site survey mapping software.
|
Universal Multimeter comes with RS232 PC interface.Omega Engineering, Inc.
Stamford, CT 06907
Apr 29, 2008
Including front keypad for input and speech mode selections as well as volume control, OMEGASAYS® UV1000 measures 0-10 Vdc voltage, 0-20 mA current, and Type K thermocouple inputs, and verbalizes them in any range with over 100 built-in engineering units. Battery powered and CE compliant unit can be configured for input range, engineering units, and high/low alarm set points. Multimeter is suited for chemical, automotive, HVAC, and paper industries.
|
 Electronic Balances feature top loading design.Shimadzu Scientific
Columbia, MD 21046
Apr 28, 2008
Featuring UniBloc aluminum integral mass sensor, TX Series electromagnetic force restoration balances offer 220-3,200 g capacity with minimum display of 0.001-0.01 g. Equipped with load-cell function, TXB Series electronic balances provide 200-6,200 g capacity and minimum display of 0.01-1 g. Both types include Smart+ menu navigation keys and Smart Setting, which allows users to adjust ratio of stability and reaction speed without interrupting current measurements.
|
 Cable Test Kit suits Wi-Fi and broadband applications.RF Industries
San Diego, CA 92126 4202
Apr 28, 2008
Housed in foam-lined impact resistant plastic case, RFA-4028-WIFI kit contains Unidapt RF Cable tester (RFA-4018-20) with 30 universal adapters, including male and female MMCX, N, Reverse Polarity TNC, Reverse Polarity SMA, TNC, BNC, and SMA connector interfaces. RFA-4018-20 coaxial cable tester is solid-state continuity checker that measures for opens and shorts. LED display indicates continuity for shield and center conductor, as well as checks for shorting across conductor paths.
|
 Portable OTDR is designed for outdoor operations.GAO Embedded Inc.
Toronto 12345 Canada
Apr 28, 2008
Weighing 1.8 kg and measuring 265 x 158 x 80 mm, Handle OTDR (optical time domain reflectometer) GAO3620 can show length, attenuation coefficient, connection point, fault point, and loss distribution curves of fiber, as well as loss between 2 points, splice loss, and return loss. With 10 ns to 10 µs pulse widths, it supports zooming in/out for curve details, automatically searches fault points and creates list, and can finish 50 km fiber measurement in 30 sec with high S/N.
|
Pressure Transducer is CE compliant.Omegadyne, Inc.
Sunbury, OH 43074
Apr 28, 2008
FM Intrinsically Safe rated, PX35 Series industrial pressure transducers are suited for chemical and automotive industries. Available in gage, absolute, or sealed models as well as psi or metric ranges, NIST traceable calibration certified units come with 3 m of 4 conductor shielded cable and twist lock connector electrical termination. NPT and 7/16-20 O-ring seal fittings are available for industrial and hydraulic applications.
|
Kit tests backflow prevention assemblies.Dwyer Instruments, Inc.
Michigan City, IN 46361
Apr 25, 2008
Comprised of 5 valves, BTK-1 Backflow Prevention Test Kit is capable of testing hydronic systems with procedures recommended by ASSE, AWWA, CSA, FCCC, HR-USC, and NEWWA. Kit includes diaphragm differential pressure gage rated for 0-15 psid, line pressure gage ranging from 0-200 psig, 4 ft long bleed tube, and three 5 ft long color-coded hoses. Brass adapter fittings enable hookup to all standard size test cocks, while 90 micron filters minimize plugging with scale and sand.
|
 Insulation Tester troubleshoots windings and cables.Ideal Industries, Inc.
Sycamore, IL 60178
Apr 25, 2008
Offering handheld portability, Model 61-795 performs routine checking of electrical insulation to spot breakdowns before they result in injury or equipment failure. Tester features CAT IV-600V safety rating, 250/500/1,000 V test voltages, and insulation test range of 0.001-4,000 MW. Additional test functions include AC/DC from 0.1-600 V, resistance from 0-200.0 W, and continuity from 0.01-20.00 W. Measurements are read on backlit digital display with analog bar graph.
|
 Roundness Tester measures ultra high precision parts.Taylor Hobson, Inc.
West Chicago, IL 60185
Apr 25, 2008
Equipped with high-precision spindle, slide way for movement along spindle axis, and another slide way for movement toward or through spindle axis, Talyrond 395 provides roundness as well as linear and circumferential roughness measurement. Unit can measure component circumferentially using diamond stylus and 72,000 radial data points, or in axial direction with 200,000 data points. With automatic centering and leveling, TR395 assures flawless alignment regardless of measurement direction.
|
 Moisture Meter suits laboratory and off-shore applications.AMETEK Petrolab Company
Broken Arrow, OK 74012
Apr 25, 2008
Using absolute technique that yields results in minutes without requiring reagent calibration, MINIHYD determines water content of crude oil, petroleum products, liquids, gases, and powders. Instrument combines coulometry with Karl Fisher (KF) method to determine water content of samples, and fully automatic operation requires one button push to conduct titration. Product works with Automatically Compensated Errors control system to ensure bias-free results.
|
 Interface Board links PMT sensors to DAQ systems.Vertilon Corporation
Westford, MA 01886
Apr 25, 2008
Board model SIB064 provides mechanical interface and electrical connectivity between Hamamatsu H8500D, a 64-element multianode photomultiplier tube, and multichannel DAQ system. High bandwidth preamplier connects directly to H8500D last dynode and provides its amplified output to one of 3 on-board pulse discriminators - leading edge, constant fraction, zero slope - to directly trigger DAQ process. Discriminators can also be bypassed for timing-sensitive applications.
|
Modules incorporate wireless connectivity into machines.Laird Technologies
Chesterfield, MO 63017
Apr 25, 2008
Suited for M2M applications, Intelligent Dual Processor 802.11 Modules feature 802.11 device server, UART interface, 12 GPIO lines, and 2 x 10-bit ADCs. One processor runs embedded interpreter with UWScript language, providing wireless connection control and capability to auto-run user scripts. At 25 x 35 mm, it also includes WLAN drivers and TCP/IP stack. Secure WEP and WPA2 implementation as well as Bluetooth co-existence and co-location support is also included.
|
(Showing headlines 7141 - 7160) << 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754
|
|
|