Test & Measuring Instruments

Optics & Photonics, Test & Measuring Instruments

Analysis System performs antisense and antigene studies.

Mar 13, 2002

Thermalmelt Tm Analysis System, for use with company's UV-Vis spectrophotometers, monitors nucleic acid dissociation as temperature is raised. It measures absorbance changes at specified wavelengths and determines melting temperature at which half of double stranded form separates. Thermodynamic parameters obtained enable prediction of thermal stability and structure of nucleic acids. Instrument... Read More

Material Handling & Storage, Test & Measuring Instruments

Force Measurement Stand suits material and spring testing.

Mar 13, 2002

Model ES30, 200 lb manual test stand has maximum travel of 13 in. and travel rate of 0.05 in./handwheel revolution. Throat clearance is 3 in. Total dimensions are 6 in. W x 10 in. D x 22 in. H. Unit is available with optional 6 in. electronic linear travel scale. Removable base allows it to be used as part of larger systems. Stand is field upgradable to motorized version by installing optional... Read More

Test & Measuring Instruments

Mechanical Analyzer monitors viscoelastic materials.

Mar 13, 2002

DMA Q800 Dynamic Mechanical Analyzer makes mechanical stress/strain measurements at temperatures from -150 to 600 deg C. It has non-contact, linear motor for precise stress control, low-friction air bearings, and optical encoder for strain detection. Sample clamps are available for operation in cantilever, 3-point bend, shear, compression and tension modes of deformation. Submersion clamps also... Read More

Electronic Components & Devices, Test & Measuring Instruments

Strain-Gage Interface Card handles multiple channels.

Mar 12, 2002

AP814 allows 8 strain gage quarter-bridges to be connected in regulated 3-wire circuit so cable resistance effects are fully compensated. All 8 channels operate simultaneously, without scanning or multiplexing. Four excitation voltages are available, providing measuring range of 4-80 mV/V. Gage or bridge factors can be set directly. Measurement-without-Excitation mode allows user to distinguish... Read More

Test & Measuring Instruments

Remote Control Interface allows integration of hipots.

Mar 12, 2002

Series 2500 features AC, DC and AC/DC hipots with test voltages up to 5,000 V and adjustable trip currents up to 100.0 mA AC, and 3.00 mA DC. Remote control allows instruments to be used in automated applications and stand-alone manual applications. Microprocessor-controlled hipots include line-and-load regulation, LED display with meter memory, tamper-resistant front panel, auto shut-down of... Read More

Test & Measuring Instruments

I/O Modules offer sequential auto addressing.

Mar 12, 2002

POINTBlocks integrate DeviceNet(TM) interface with array of 16-point I/O starter blocks. One- to four-channel POINT I/O(TM) modules can be snapped to base for expansion up to 264 I/O points. Modules provide protected outputs with option of latching off or pulse retry configuration, I/O messaging options, gold alloy contacts to facilitate low voltage applications, vertical and horizontal mounting,... Read More

Test & Measuring Instruments

Power Quality Analyzer offers intelligent download.

Mar 12, 2002

PA-9Plus provides 12 megabytes of internal storage, on-board auxiliary power input capabilities, and optional removable flash memory card. Metrosoft AVO PA-9W software enables unit to trend imbalance, individual harmonics, THD and TDD, and preview and download only what is required. Chart analysis is simplified through zoom/unzoom capabilities. PA-9Plus complies with all applicable IEC, IEEE and... Read More

Sensors Monitors & Transducers, Test & Measuring Instruments

Measuring Wheels work with encoders to measure linear motion.

Mar 12, 2002

Measuring Wheels are available in 6 in., 12 in., 1/3 meter, 200mm, 300mm, 400mm, and 500mm with choice of rubber or knurled aluminum contact surfaces. Cube Series Accu-Coder(TM) encoders with dual shafts work well in measuring wheel applications, since putting measuring wheel on each shaft results in twice the traction and improves bearing load by leveling radial pressure. Read More

Test & Measuring Instruments

Conductivity Instrument measures eddy currents.

Mar 12, 2002

Phasec 2s measures conductivity over range of 1%-110% IACS, and provides non-conductive coating thickness measurement using dedicated conductivity probe. Rotating probe can inspect fastener holes using either standard Hocking probe drive or Hocking Mini drive. Phasec 2s has operating frequency range of 100 Hz to 6 MHz in 900 steps, with gain of 0 to 85 dB in 0.1 dB steps. It includes 5-1/2 in.... Read More

Test & Measuring Instruments

Pressure Transmitter suits HVAC monitoring and control.

Mar 12, 2002

LPX 1000LCD wet/wet differential pressure transmitter is available in 2 diameters, allowing installation directly into existing mechanical gauge applications. It offers standard accuracy of 0.5% FS, and standard ranges of ±0.1 to ±6 in. H2O, 2-wire, 4-20mA output. Excitation voltage is 15 to 30 Vdc. Damping adjustment feature allows user to slow response time to eliminate nuisance trips of... Read More

Electronic Components & Devices, Sensors Monitors & Transducers, Test & Measuring Instruments

Electronic Module cleans up encoder signals.

Mar 12, 2002

Anti-Dither Module can be placed between encoder and receiving electronics. DIN rail mountable device compares quadrature outputs from encoder, removes errors caused by mechanical vibration, and gives true picture of system output. Applications include web processes, conveyors, in-line inspection stations, and heavy equipment. Read More

Sensors Monitors & Transducers, Test & Measuring Instruments

pH/ORP Sensors use differential electrode technology.

Mar 12, 2002

pHD(TM) electrode sensors use 3 measuring electrodes. Process and reference electrodes measure pH differentially, with respect to third ground electrode, reducing reference junction fouling and minimizing ground loops. Preamplifier boosts electrodes' mV signals for transmission up to 3,000 ft. PEEK(R) and Ryton(R) bodies provide chemical resistance in aggressive process solutions. Convertible,... Read More

Test & Measuring Instruments

Flow Indicator uses microwave technology.

Mar 12, 2002

Solids Flow Indicator (SFI) detects flow in solid material applications including gravity chutes and pneumatic pipelines. SFI offers analog output and non-contact/non-intrusive design. Housing is rated for Class II dust-ignition proof environments, and meets NEMA 4 water-tight and dust-tight classifications. Other features include built-in averaging adjustment and LED indicators. Read More

Test & Measuring Instruments

Data Collector works in harsh environments.

Mar 12, 2002

Portable, water-resistant PulseStar reads Dallas Semiconductor's iButtons. Upon successfully reading button's unique ID number, it gives vibrating pulse rather than audio tone. Housed in metal case and sealed with O-rings, internal components are protected against shock damage associated with repetitive drops. Applications include security guard tour tracking, inmate tracking, jail checks,... Read More

Test & Measuring Instruments

Hardness Tester is unaffected by part's mass or thickness.

Mar 12, 2002

Portable TIV (Through Indenter Viewing) instrument tests metals and some non-metallic materials. It uses traditional pyramid-shaped Vickers diamond that is pressed into material under defined test load. CCD camera monitors event and creates image on instrument's LCD. Diagonals of indentation are automatically measured and hardness value instantaneously displayed. Read More

Test & Measuring Instruments

RTD Input Modules connect to Modbus.

Mar 12, 2002

Dual/quad-channel BusWorks(TM) 930MB Series I/O captures data from up to 4 RTD temperature sensors or resistance input signals for communication over Modbus network. It has 4 built-in solid-state relays for independent local alarms or on/off switching functions. Setup is via Windows(R) configuration software for selection of input/output ranges, limit alarms, and other operating parameters.... Read More

Test & Measuring Instruments

I/O Modules interface with DeviceNet(TM).

Mar 12, 2002

16-channel POINTBlock I/O Modules, with 60 mm footprint, including DeviceNet interface, include 120 Vac 1734D-IA16 and 1734D-IA16S, and 24 Vdc 1734D-IB16 and 1734D-IB16S. All have sequential auto addressing for simplified commissioning of expansion modules; protected outputs with option of latching off or pulse retry configuration; I/O messaging options for optimized I/O memory and network... Read More

Optics & Photonics, Sensors Monitors & Transducers, Test & Measuring Instruments

Rotary Encoder suits tight constraint applications.

Mar 12, 2002

MOD 700 is comprised of LED and OptoASIC configured into small caliper, offering resolutions as high as 2,540 PPR. Opto-ASIC phased array photo diode IC features high tolerance for axial movement (+/- 0.010 in.) and power consumption of 40 mA. Standard stainless steel code disk offers range of standard optical radii, from .375 to .860 in. MOD 700 can be surface mounted onto PCBs or installed onto... Read More

Mechanical Components and Assemblies, Test & Measuring Instruments

Field Retrofit Kit upgrades crankshaft gage.

Mar 11, 2002

Upgrade Package for Model 1200 crankshaft gage includes sealed and cooled electronic cabinet with UPS, Pentium PC, color printing/plotting, and 19 in. color monitor with touch screen and sealed keyboard. It also includes head stock drive motor and laser reference optics. Retrofit package improves user interface, increases data density to 1,440 points, and is 20% faster, allowing it to perform... Read More

Sensors Monitors & Transducers, Test & Measuring Instruments

Pressure Transmitter measures vacuum.

Mar 11, 2002

NIST-traceable Model FPV provides vacuum pressure measurements from 10 in. water to 15 psiv. Selectable parameters include choice of 0.1% or 0.25% accuracy, 6 electrical terminations, 6 pressure ports, and 0-5 Vdc, 0-10 Vdc, 2-wire 4-20 mA, or mV/V output. Long-term stability is 0.04% FS for 30 months. Certifications are available for CE and for intrinsically-safe installations. Read More