ThomasNet News Logo
Sign Up | Log In | ThomasNet Home | Promote Your Business
 Journals
Industry Market Trends ®
Fluid & Gas Flow Journal
Machining Journal
Procurement Journal
Tech Trends Journal
 Industry News
Latest New Product News
Association & Government News
Thought Leaders
 Product News
Adhesives and Sealants
Agricultural and Farming Products
Architectural and Civil Engineering Products
Automatic ID
Chemical Processing and Waste Management
Cleaning Products and Equipment
Communication Systems and Equipment
Computer Hardware and Peripherals
Construction Equipment and Supplies
Controls and Controllers
Display and Presentation Equipment
Electrical Equipment and Systems
Electronic Components and Devices
Explosives, Armaments and Weaponry
Fasteners and Hardware
Fluid and Gas Flow Equipment
Food Processing and Preparation
Green & Clean
Health, Medical and Dental Supplies and Equipment
HVAC
Labels, Tags, Signage and Equipment
Laboratory and Research Supplies and Equipment
Lubricants
Machinery and Machining Tools
Material Handling and Storage
Materials and Material Processing
Mechanical Components and Assemblies
Mechanical Power Transmission
Mining, Oil Drilling & Refining
Mounting and Attaching Products
Non-Industrial Products
Optics and Photonics
Packaging Products & Equipment
Paints and Coatings
Plant Furnishings and Accessories
Portable Tools
Printing and Duplicating Equipment
Retail and Sales Equipment
Robotics
Safety and Security Equipment
Sensors, Monitors and Transducers
Services
Software
Test and Measuring Instruments
Textile Industry Products
Thermal and Heating Equipment
Timers and Clocks
Transportation Industry Products
Vision Systems
Waste Handling Equipment
Welding Equipment and Supplies
 Press Releases
Products in the News
Company News
Mergers & Acquisitions
People in the News
Literature & Websites
 Resources
News Delivery Options
Newsletter Archive
SME
Browse Categories
Browse Companies
Mobile Edition
PR Resources
Licensing
Advertising
Call for Contributors, Guest Writers and Submissions
How to Write an effective Press Release
Trade Associations
Sensors Monitors & Transducers -> Transducers -> Temperature & Humidity Transducers


Temperature & Humidity Transducers







(Showing headlines 1 - 20)   more ....
Wireless Transmitter System obtains remote temperature readings.

Wireless Transmitter System obtains remote temperature readings.

Moore Industries International, Inc.    North Hills, CA 91343
Jul 02, 2014 Combining THZ Smart HART Temperature Transmitter and BULLET WirelessHART Adapter, self-powered THZ WirelessHART Temperature solution can obtain accurate temperature readings in remote locations while accessing Smart HART® data. WL housing includes battery case utilizing D-type lithium batteries, which last up to 4 or 5 years. Along with 20-bit input resolution, features include up to 5 years of service between scheduled calibrations and support for programming via DTM with FDT-compliant host.

Carbon Dioxide Transmitters combine 3 room sensors.

Carbon Dioxide Transmitters combine 3 room sensors.

Dwyer Instruments, Inc.    Michigan City, IN 46361
Jun 30, 2014 Suited for on demand ventilation, Series CDTA combines carbon dioxide, humidity, temperature, occupancy override, and temperature set point measurements in one. Transmitters use Single-Beam, Dual-Wavelength NDIR sensor for carbon dioxide, capacitive polymer sensor for humidity, and band gap sensor for temperature. Field selectable BACnet or Modbus® communications transmit measurements to building controller and allow transmitters to be daisy chained with other communicating sensors.

Thermocouple Transmitter offers Ethernet and 4-20 mA outputs.

Thermocouple Transmitter offers Ethernet and 4-20 mA outputs.

Laurel Electronics, Inc.    Costa Mesa, CA 92626
Jun 20, 2014 Housed in DIN-rail package, Laureate™ LTE-TC combines Ethernet I/O, isolated 0–10 or 4–20 mA analog output, and dual 120 mA relays. Signal board and linearization software provide stable and repeatable output for thermocouple types J, K, T, E, N, R, or S. Thermocouple type and temperature range, specified in °C or °F, are user-selectable. Discovery of transmitters connected to LAN is automatically achieved with Node Manager Software, and discovered transmitters can be programmed over Ethernet.

Temperature Transmitters improve plant and employee efficiency.

Temperature Transmitters improve plant and employee efficiency.

Honeywell International    Houston, TX 77014
Jun 11, 2014 Compatible with Experion® Process Knowledge System, SmartLine™ help reduce project startup time and unplanned downtime. Graphic display shows process data in graphical formats as well as messages from control room, and modular components facilitate field repair and reduce parts inventory requirements. To promote plant reliability and safety, features include dual-compartment housing, transmitter and sensor diagnostics, wiring polarity insensitivity, and real-time display of diagnostics.

Programmable RTD Temperature Transmitters have M12 connection.

Programmable RTD Temperature Transmitters have M12 connection.

Omega Engineering, Inc.    Stamford, CT 06907
Jun 06, 2014 Along with M12 thread design that offers secure industrial fit, M12TXC series features 4–20 mA output and 0.51 and 0.94 in. long x 0.12 in. dia Thermowell AISI 316L stainless steel probe suitable for areas with space limitations. RTD 100 Ω sensor has built-in transmitter and 1/8 NPT process connection and is programmable via computer. Range of -58 to +248°F suits applications in Food and Beverage, Chemical/Petrochemical, Pharmaceutical, Pumps, and Plumbing industries.

DP Level Transmitter does not use impulse lines, capillary tubes.

DP Level Transmitter does not use impulse lines, capillary tubes.

Endress+Hauser    Greenwood, IN 46143
Jun 04, 2014 Using Ceraphire ceramic sensor in pressure sensor modules, Deltabar FMD71 calculates differential pressure (DP) from 2 pressure sensor modules, each connected electronically to single transmitter, and transmits level, volume, or mass via 4–20 mA with HART as standard 2-wire, loop-powered device. Electronic system eliminates issues associated with impulse lines or capillaries, such as icing, clogging, leaks, condensation, and changing ambient temperatures.

Humidity/Temperature Transmitter uses field-replaceable sensors.

Dwyer Instruments, Inc.    Michigan City, IN 46361
May 08, 2014 Supplied in wall-mounted, vented housing, Series RHP-E/N is available with optional integral LCD that indicates ambient temperature along with humidity or dew point. Remote display is also available for building balancing or LEED® validation. Humidity and dew point, measured using capacitive polymer sensor that completely recovers from 100% saturation, can have current or voltage output, while optional temperature output can be current, voltage, RTD, or thermistor.

Transmitter enables dual parameter measurement and monitoring.

Rotronic Instrument Corp.    Hauppauge, NY 11788
Apr 29, 2014 Able to integrate with existing monitoring system, PF4 series can be used for differential pressure (DP) and humidity/temperature measurement and monitoring. Transmitter, immune to dust and humidity, comes with optional connector for HC2-probes, integrated relay switch contact, and overload capabilities. Offering long-term stability, freely configurable analog signals, and selectable units, DP transmitter allows another measurement parameter within HW4 software and network.

DC-DC Converters suit distributed power applications.

DC-DC Converters suit distributed power applications.

Murata Power Solutions    Mansfield, MA 02048
Mar 07, 2014 Packaged in eighth brick format measuring 58.4 x 22.9 x 10.7 mm, DOSA-compliant UEE Series is available with mounting pins or as surface mount devices. Series comprises 3 models with 2:1 input voltage range of 36–75 Vdc and output voltages of 3.3, 5, or 12 Vdc. Providing typical efficiency of 92%, 150 W units have tight line regulation of ±0.1% and load regulation up to ±0.25%. Basic input/output isolation is 2,250 Vdc and complies with safety standard EN/UL/EC 60950.

Smart Temperature Transmitter features HART protocol.

Maxim Integrated Products    Sunnyvale, CA 94086
Mar 04, 2014 Using HART communication protocol, Novato Reference Design transmits temperature measurements from remote sensors to central control unit over 4–20 mA current loop. Unit consumes less than 3.2 mA while providing measurements from -200 to +850°C with better than ±0.1% accuracy. Supporting 2-, 3-, or 4-wire RTD sensor inputs, transmitter works with any type of RTDs, from PT100 to PT1000, making it suitable for variety of industrial applications.

Pressure Transducer delivers 0.25% FS accuracy.

Gems Sensors Inc.    Plainville, CT 06062
Feb 10, 2014 Available in 7 pressure ranges from 0–14.5 psi to 0–232 psi, 3500 series operates over -40 to +257°F range, and offers absolute, compound, and gauge reference capability for applications across medical and general industrial markets. Products are designed for >100 million FS cycles, with long term drift of 0.2% FS/year. These 1.77 in. long, 1.23 oz transducers, with 316L stainless steel wetted parts and all-welded construction, also employ MEMS technology.

Thermal Mass Flowmeter survives harsh industrial environments.

Fox Thermal Instruments, Inc.    Marina, CA 93933
Dec 24, 2013 Offering BACnet MS/TP, RS485 Modbus, Profibus-DP, DeviceNet, and Ethernet Modbus TCP communications options, FT2A features dual 4–20 mA outputs – one for flow and other selectable for flow or temperature – and pulse output (pulses per unit/units per pulse). FT2A View™ software, included, allows adjustments to meter configuration, evaluation of alarm conditions, collection of process data, and measurement viewing from PC or control station. USB port allows direct connection to PC.

Safety Transmitter features SIL 2 certification.

United Electric Controls    Watertown, MA 02472
Dec 13, 2013 Designed solely for safety applications, One Series Safety Transmitter is available in versions that monitor temperature and pressure. Unit provides 4–20 mA NAMUR standard output with I Am Working™ diagnostics. High-speed safety relay output supports local alarm or emergency shutdown, while discrete outputs deliver diagnostics and relay status voting logic input to safety PLC. Approved for hazardous locations, transmitter achieves safe failure fraction of 98.5% and response time of <100 ms.

Sanitary Temperature Transmitters meet 3A standards.

Sanitary Temperature Transmitters meet 3A standards.

ifm efector, Inc.    Exton, PA 19341
Sep 11, 2013 Supplied in one-piece, stainless steel housing, TD Series withstands harsh environments of food and beverage applications. Integrated transmitter electronics, process connector, and Pt1000 Class A RTD probe are laser-welded and IP69K-sealed. Resistant to corrosive effects of chemicals and harsh industrial cleaners, 2-wire loop powered transmitter is pre-scaled for ranges of 0 to +100°C and 0 to +300°F. Reaction speeds are 1 sec to 50% and 3 sec to 90% of temperature change.

Temperature Transducers feature low transmission error of 0.1%.

Temperature Transducers feature low transmission error of 0.1%.

Phoenix Contact    Harrisburg, PA 17111 0100
Aug 15, 2013 Offering wide power circuit input range of 9.6–30 Vdc, MINI Analog Series includes 2 universal software-programmable temperature transducers that convert and condition signals from common RTDs as well as thermocouple temperature sensors. Suited for battery-powered or remote systems, units have 6.2 mm thick housing and T-bus power bus capabilities. Hot-swappable signal conditioning slices clip to powering T-bus connector without need to remove bus bars or bridging.

DIN Rail Temperature Transmitters offer 1 ms response.

DIN Rail Temperature Transmitters offer 1 ms response.

JH Technology, Inc.    Bradenton, FL 34211
Jul 10, 2013 With Option HS offering 1 ms response time, JH5000 Series is suited for some experimental and test applications, including combustion studies, solar studies, and some wind tunnel tests. All-analog design uses precision linear optocoupler to provide galvanic input isolation and avoids processing delay inherent in most microprocessor approaches. Option is also available for DC, strain gauge, and potentiometer inputs.

A/D Converters operate in temperatures up to 200°C.

A/D Converters operate in temperatures up to 200°C.

DATEL    Mansfield, MA 02048
May 02, 2013 Rated for operation over -55 to +200°C temperature range, ADS-1201 series A/D converters feature 12-bit resolution, 1 MHz sampling rate, and no latency delays. Units have unipolar and bipolar input range, 1,000 hr continuous operating life at 200°C, and precision internal reference. They are manufactured on thick film ceramic using low-temperature drift thin film resistors on 96% alumina substrate. Available packaging options include 8-pin DDIP or SMT hermetically sealed ceramic package.

Virtual Chart Recorder monitors over Ethernet network.

Virtual Chart Recorder monitors over Ethernet network.

Omega Engineering, Inc.    Stamford, CT 06907
May 01, 2013 With iTHX-SD Transmitter, user can monitor and record temperature, relative humidity, and dew point over Ethernet network or Internet with no special software required. Unit serves Active Web Pages to display real-time readings, display charts of temperature and humidity, or log data in standard data formats for use in spreadsheet or data acquisition program such as Excel or Visual Basic. Using 2 GB SD Flash Memory card, iTHX-SD can store up to 7 years of readings taken at 10 sec intervals.

Transmitters and Actuators support bioreactor controllers.

Finesse Solutions, LLC    Santa Clara,, CA 95054
Apr 08, 2013 Designed for R&D scale-up and cGMP, SmartParts™ family of intelligent transmitters and actuators are building blocks for plug-and-play bioreactor controller systems that can control any size or type of upstream vessel. Units have built-in diagnostics, programmable functionality, and local control that is optimized for function of each component. When components are plugged into Finesse control system, they are automatically recognized with many settings configured automatically.

Transmitter supports batch controller capabilities.

Transmitter supports batch controller capabilities.

GF Piping Systems    Tustin, CA 92780-7258
Apr 02, 2013 Signet 9900 Transmitter (Generation II) supports multiple parameters, including flow, pH/ORP, conductivity/resistivity, salinity, temperature, pressure, level, and 4–20 mA signals, and batch systems. In addition to saving up to 10 batch sizes, capabilities include customizable batch names, entry of K-factors for each batch, confirmation for preventing accidental batch starts, manual batch feature for topping off, override batch size function, and batch count indicator.




(Showing headlines 1 - 20)   more ....


Home  |  My ThomasNet News®  |  Industry Market Trends®  |  Submit Release  |  Advertise  |  Contact News  |  About Us
Brought to you by Thomasnet.com        Browse ThomasNet Directory

Copyright © 2014 Thomas Publishing Company. All Rights Reserved.
Terms of Use - Privacy Policy