 Infrared Emitter features viewing angle of ±38°.Vishay Intertechnology, Inc.
Malvern, PA 19355 2143
May 07, 2008
Model TSFF5510 870 nm emitter offers forward voltage of 1.45 V at 100 mA and 2.15 V at 1 A for uniform operation. It has switching times of 15 ns, supporting data transmission rates of up to 16 Mbps, as well as 55 mW optical power at 100 mA and radiant intensity of 32 mW/sr at 100 mA. Compact package has lens radius of 2.35 mm, lens height of 3.8 mm, lens width of 4.8 mm, epoxy bottom plane diameter of 5.9 mm, and lead distance of 2.54 mm. Unit is also lead-free.
|
Subsystem Platforms promote DSP integration.CEVA, Inc.
San Jose, CA 95110-3710
Apr 23, 2008
While CEVA XS-1100A is optimized for wireless baseband applications, and CEVA XS-1200A is aimed at multimedia and other applications requiring high-performance signal processing, both configurable hardware platforms offer verified approach for integrating CEVA-X DSP cores into complex system on chips (SoCs). Use of industry-standard system buses enables designers to add their own hardware blocks or connect DSP to other systems present on chip.
|
 Infrared Optics feature moldable design.Rochester Precision Optics
Rochester, NY 14586
Mar 03, 2008
Optir(TM) moldable long wave infrared glass and infrared aspheric optics utilize benefits of moldable infrared chalcogenide glasses. Glass offers minimal thermal change in refractive index of 72 x 10-6/ºC, which benefits systems designers in avoiding thermal defocusing.
|
Integration Appliance meets healthcare industry needs.Meddius, LLC
Charlottesville, VA 22902
Feb 27, 2008
Able to process over 5.5 million HL7 messages/hr, Integration Router(TM) provides data transformation, communication, and routing functions between clinical healthcare applications. Core engine provides transport mediation and message transformation between disparate formats, allowing hospitals to integrate data residing in separate applications without new software infrastructure. Rack-mountable and scalable solution offers turnkey functionality.
|
Toolkit facilitates implementation of adaptive optics.ThorLabs
Newton, NJ 07860
Jan 25, 2008
Offered as turnkey solution, Adaptive Optics (AO) Toolkit allows researchers to integrate adaptive optics into their research systems within hours. Kit is comprised of Thorlab WFS150C Shack-Hartmann Wavefront Sensor, with 1.3-megapixel CCD camera; BMC 140 actuator Multi-DM deformable mirror system; and software that minimizes wavefront distortion. Control software also lets user monitor wavefront corrections and intensity distribution in real time.
|
 Field Replacement Optics suit plastic cutting applications.Meller Optics, Inc.
Providence, RI 02940
Nov 19, 2007
Optimized for use at 10.6 µm, CO2 Lenses and Mirrors meet OEM and ISO-10110 specifications for optical elements and are compatible with low-power CO2 lasers used for cutting, marking, and de-gating plastics. CO2 Lenses are A/R coated and available in ½ to 1½ in. dia sizes with focal lengths from 1-25 in. in ½ in. increments; dual-band coatings are offered to aid in system alignment. Made from silicon, molybdenum, and copper, CO2 Laser Mirrors and reflectors are ½-10 mm thick.
|
 Reflective Object Sensor detects diffuse materials.Optek Technology, Inc.
Carrollton, TX 75006-6905
Nov 06, 2007
Available with axial, gull wing, or right angle lead configurations, Series OPB609 sensors consist of 940 nm infrared LED that has maximum forward voltage of 1.7 V and reverse dc voltage of 5 V and NPN silicon phototransistor mounted side-by-side on parallel axes. Units feature 50 mA forward dc current with maximum reverse current of 10 µA and peak forward current of 1 A, 75 mW power dissipation rating, and -25 to +85°C operating temperature range.
|
MSA-Compatible TOSA offers extended L- and C-band coverage.Bookham, Inc.
San Jose, CA 95134
Sep 13, 2007
Incorporating buried hetrostructure laser, 2.5 Gbps transmit optical subassembly (TOSA) has transmission capability of 125 Mbps to 5.3 Gbps over 1,600-6,000 ps/nm dispersion, with extinction ratio of greater than 10 dB. At OC48 data rate, it has reach of up to 360 km in C band and 200 km in L band. Product is designed as in-feed to TDM, CWDM, and DWDM SFP markets and can also be used to replace 14-pin butterfly direct modulated lasers on card applications.
|
Fibre Fault Detector locates breaks/bends in optical cabling.Photonic Products, Ltd.
Huntington Beach, CA 92647
Sep 04, 2007
Pocket sized FFD100 Fibre Fault Detector visually finds discontinuities that result in signal loss, and aids end-to-end fiber identification within bundle. It uses high visibility 635 nm red laser diode with CW operation to locate faults up to 5 km. Measuring 162 mm and weighing 70 g, unit features Universal Adaptor and accepts all standard 2.5 mm optical connector types for single and multimode operation.
|
 Digital Cameras are designed for photo-micrography.Carl Zeiss Microimaging, Inc.
Thornwood, NY 10594-1939
Feb 06, 2007
Offering respective resolutions of 1,392 x 1,040 and 2,028 x 1,540 pixels, 1.4 megapixel AxioCam ICc1 and 3.3 megapixel AxioCam ICc3 are suited for users who work with laboratory and routine microscopes or simple stereomicroscopes. Both cube-shaped cameras have edge length of 4 cm and offer variety of exposure times. Operating on power supplied via FireWire data cable, AxioCam ICc1 captures up to 17 images/sec and AxioCam ICc3 captures 6-39 images/sec.
|
IR Illuminator offers up to 50 J/flash of intensity.PerkinElmer, Inc., Optoelectronics Headquarters
Fremont, CA 94538-3180
Dec 19, 2006
Available in narrow and wide beam configurations, Model VIGI-Lux(TM) 5770 features Xenon flashlamp that covers full light spectrum from UV through visible to IR. Modular architecture offers flexibility in configuring end products, while IR long-pass filter removes wavelengths under 780 nm, making strobe invisible to naked eye. Illuminator is suited for license plate recognition, infrared surveillance, and machine vision applications.
|
 LED Module targets biomedical applications.Opto Technology Inc.
Wheeling, IL 60090 6056
Nov 13, 2006
Suited for applications requiring full, UV to Red spectrum, OTLA-0130 broadband white LED light engine integrates white LED with monochromatic LED die to expand spectral output. Light emitting source of less than 2 mm dia in size allows it to be coupled to optical systems such as fiber optics and focusing optics. Each LED wavelength, including white, 395, 470, 630, and 660 nm, can be individually addressed for separate pulsing and intensity balancing.
|
 Zinc Sulfide Optics transmit over 0.4-12 µm wavelength.Meller Optics, Inc.
Providence, RI 02940
Aug 15, 2006
Laser Research zinc sulfide (ZnS) Optics feature high transmission with minimal scatter and are designed for broad wavelength applications. Typically supplied with broadband A/R coatings, these water-clear, multi-spectral optics are suited for use in IR imaging and military FLIR systems. Chemically inert and non-hygroscopic products, offered in ¼-4 in. dia sizes from 1-8 mm thick, have surface accuracies to ¼ wave and 40-20 scratch-dig per MIL-PRF-13830.
|
Sapphire Optics can withstand extreme environments.Meller Optics, Inc.
Providence, RI 02940
Aug 08, 2006
Custom Sapphire Optics are manufactured to specification for applications that require clear, chemically inert window, lens, cube, or cover that is impervious to water and can withstand pressures to 10,000 psi. Offered in sizes from ¼-10 in. dia and ½ mm to 1 in. thick, optics are available with drilled holes, slots, wedges, stepped edges, elliptical edge shaping, or metallization. Flatness can be held to 0.5 fringes of HeNe, with parallelism from 20-2 arc/sec.
|
Spectrometer is laser and amplifier compatible.Del Mar Photonics, Inc.
San Diego, CA 92130
Aug 03, 2006
Beacon Femtosecond Fluorescence Upconversion Spectrometer measures fluorescence in 400-1,500 nm range and is used for applications in cell biology, photophysics, femtochemistry, materials science, and nanoscience. Featuring footprint of 10 x 24 x 36 in., unit offers time scale of 1,600 ps, 6.6 fs step size, <140 fs temporal resolution, repetition rate of pulses 1 kHz to 82 mHz, and average power of >0.6 W. Software provides 2D and 3D display of wavelength, time, and emission intensity.
|
 Reflective Color Sensing Assembly sorts surfaces by color.Optek Technology, Inc.
Carrollton, TX 75006-6905
Jul 31, 2006
Used in photometric applications, OPB780 digitally measures red, green, and blue components of light reflected from surface being sensed. Product utilizes white LED to illuminate surface of object or liquid being sensed, while reflected light is received by 8 x 8 photodiode array. Operating from 5 V power supply, product measures 1.08 x 0.843 x 0.355 in. and is housed in plastic design capable of being mounted to PCB or flush-mounted to surface using clips.
|
 Transmission Spheres are used with interferometers.Melles Griot Optics Group
Rochester, NY 14620
Jul 07, 2006
High-precision λ/40 Absolute(TM) Fizeau Transmission Spheres are available with f-numbers of f/0.76, f/1.5, f/2.2, and f/3.3. Clear aperture, 100 mm spheres are manufactured utilizing subaperture stitching interferometry (SSI®) and magnetorheological finishing (MRF®) technologies, and are suited for Zygo® style Fizeau surface and transmitted wavefront testing interferometers.
|
Dispersion Compensator features low-loss design.Avanex Corp.
Fremont, CA 94538
Apr 28, 2006
Suited for single-mode fiber and LEAF® transmission fibers, low-loss Dispersion Compensation Module (DCM®) maintains all critical optical specifications of standard dispersion management solutions while reducing optical power loss. Product also allows for broad hut-skipping deployment, which places DCMs in network at every other node instead of every node.
|
 Sorter offers laser-sensing technology.Key Technology, Inc.
Walla Walla, WA 99362
Jan 19, 2006
Optyx® 3000 Series sorter suits packaging lines handling up to 6 tons of product per hour. As Class I laser sorter, Optyx® 3000 maximizes simultaneous detection and removal of defects and foreign material. Using high intensity discharge illumination system and CCD-based camera, sorter analyzes size, shape, and subtle color differences. Compact, self-contained unit connects to air, power, and water within processing line.
|
 Upgrade Package supports optical sorting systems.Key Technology, Inc.
Walla Walla, WA 99362
Nov 29, 2005
Suited for updating electronics and optics in Key legacy sorters up to 20 years old, G6 Upgrade Package includes advanced vision engine, color and VIS/IR cameras, as well as CameraLink, FireWire, and Ethernet broadband connectivity standards. Image Processing Module features FPGA chipset, which puts power of entire electronic rack in single chip. GUI resides locally on system's controller but can also be accessed remotely via network or Internet.
|