|
|
|
|
Mechanical Power Transmission ->
Mechanical Amplifiers
Mechanical Amplifiers
(Showing headlines 1 - 20) more ....
|
 Transconductance Amplifier enables accurate calibration.Fluke Corp.
Everett, WA 98203
May 10, 2012
Transconductance Amplifier 52120A expands precision calibration capabilities to power and energy meters, clamp meters, current transformers, and Rogowski coils rated up to 6,000 A. Unit supplies DC current to 100 A and AC current up to 120 A at accuracies to 140 ppm; generates 3,000 or 6,000 A when using accessory coils; and can output up to 360 A when 3 amplifiers are connected in parallel. Also, amplifier has inductive drive capability of 1 mH and compliance voltage of 4.5 V.
|
Polymerase Chain Reaction System amplifies PCR up to 1 kbp within 30 min.Ahram Biosystems, Inc.
Seoul 133-120 Korea (south)
May 01, 2012
For downstream applications requiring nucleic acid amplification, portable Palm PCR(TM) F1-12 provides 3 standard fast speed levels and delivers 30-cycle PCR amplification within 24-30 min. Amplification sensitivity reaches to near single-copy level below 10 copies, and dynamic range of PCR amplification is up to 1 kbp. Measuring 2.8 x 4.76 x 1.85 in. and weighing 350 g, instrument can operate continuously for 4+ hr on one battery charge and offers temperature uniformity of less than ±0.1°C.
|
GNSS Receiver and Amplifier have automotive-grade design.Maxim Integrated Products
Sunnyvale, CA 94086
Mar 27, 2012
Designed for GNSS applications, MAX2769B and MAX2670 feature PPAP and AEC-Q100 approvals and operate over navigation standards: GPS, GLONASS, Galileo, and Compass. Dual-stage low noise amplifier, MAX2670, is typically located in or close to antenna module, while MAX2769B resides within dashboard as receiver and has noise figure of 1.4 dB. MAX2670's design allows external filtering between first and second stage, providing flexibility for system optimization.
|
 Switch Amplifiers include line fault detection.Pepperl + Fuchs, Inc.
Twinsburg, OH 44087 2245
Sep 09, 2011
With Line Fault Transparency, Switch Amplifiers enable users to simultaneously transfer switch and fault signals via single output. Models NIC2831 and HIC2832 are 1- and 2-channel units suitable for mounting on termination boards, while K-System KFD2-SOT2-EX1.N provides line fault transparency to control system in standard DIN rail mount configuration. Amplifiers provide comprehensive monitoring of field and control lines while minimizing amount of wiring required in hazardous areas.
|
 Multichannel Amplifier Module fosters scalable measurement.HBM, Inc.
Marlborough, MA 01752 3014
Mar 31, 2011
Able to work with large number of different sensors, 16-channel MX1601 ensures flexibility in applications with mainly active sensors or acceleration transducers. All physical measurands measured via standardized voltages or currents can be acquired, and current-fed, piezoelectric transducers can also be connected. While sensor connection is facilitated via push-in technology, TEDS support enables connected sensors to be automatically identified and configured.
|
 Process Controllers are available with software interface.HBM, Inc.
Marlborough, MA 01752 3014
Oct 14, 2010
Used for monitoring press-fitting processes or implementing switch checks, respectively, MP85A FASTpress and MP85A-S EASYswitch utilize software interface for connection to IPM process data management software. Controllers can be seamlessly integrated into appropriate system via IPM interface so that acquired production data can be directly transmitted to quality assurance server for visualization and archiving. In addition, data can be observed in real-time via web browser.
|
Headphone Amplifier is capable of operation from 0.93 V.Rohm Electronics USA LLC
Antioch, TN 37013
Aug 30, 2010
Accommodating compact, portable equipment put to continuous use that requires extended operating times from one battery, BU7150NUV supports operating power supply ranges of 0.93-3.5 V and 1.03-3.5 V. Automatic startup sequence control circuit, power ON reset function, and clicking/popping noise reduction circuit promote optimal performance, while 1 mA operation promotes battery life. Other features include thermal shutdown circuit and selectable BTL connection.
|
 Non-Contact Displacement Amplifier has nanometer resolution.Capacitec, Inc.
Ayer, MA 01432
Jun 15, 2010
Supplied in standard OEM package measuring 2.2 x 3.9 x 0.50 in., model 410-XSC single-channel capacitance amplifier is compatible with new and existing non-contact displacement and gap probes. Open frame promotes flexibility, and optional compact enclosure with power supply is available. For applications requiring use of multiple sensors, boards can be rack-mounted and optionally connected to Capacitec Bargrafx(TM) LabView®-based data acquisition and display software.
|
 Motion Control System has standard NEMA 23 frame dimensions.Animatics Corp.
Santa Clara, CA 95054
Dec 01, 2009
Suitable for OEM applications, compact SmartMotor(TM) model SM2337DT incorporates servo motor, amplifier, and motion controller into same integral frame. It delivers up to 200 oz-in. of peak torque while maintaining as much as 60 oz-in. of continuous torque.
|
 Power Amplifiers target EMC testing applications.Instruments For Industry, Inc.
Ronkonkoma, NY 11779
Oct 13, 2009
Available at power levels from 10-500 W, IFI CMC300 Series provides minimum of 300 W of CW power for 10 MHz to 1.0 GHz frequency range. Single-drawer units feature compact design measuring 10.5 in. H (depending on power level and options) x 19 in. W x 25.25 in. D. Amplifiers are suited for high power test requirements for pre-compliance testing, EMC testing, and all lab and test installations.
|
Amplifier provides radiated susceptibility testing.Instruments For Industry, Inc.
Ronkonkoma, NY 11779
Sep 21, 2009
Solid-state SMXE-200-2G Series power amplifier provides minimum of 200 W of CW power for frequency range of 10 KHz to 2.0 GHz. Measuring 19 x 10.5 x 27 in. and weighing 60 lb, compact, solid-state power amplifier simplifies EMC and other RF/Microwave testing for low-to-high power test applications. It can also be used for pre-compliance testing, as well as all lab and test requirements.
|
Amplifier is intended for testing applications.Instruments For Industry, Inc.
Ronkonkoma, NY 11779
Feb 26, 2009
Designed specifically for bellcore testing, Model T101-100-50 single drawer amplifier measures 17.5 x 19 x 27 in. Compact, lightweight amplifier unit provides minimum of 100 W up to 4.0 GHz and 50 W to 10 GHz with better than -20 dBc harmonic levels.
|
Post Amplifiers drive devices with CML and PECL inputs.Micrel Semiconductor Inc.
San Jose, CA 95131
Jan 04, 2008
Featuring high-sensitivity Loss-Of-Signal (LOS) circuits suited for detecting small input signals, SY88343HL and SY88289HL connect to transimpedance amplifiers in fiber optic module, quantize their linear signal, and output them in low noise CML-level waveforms. ICs amplify input signals as small as 4 mVpp and are optimized to operate over range of data rates from 155 Mbps to 3.2 Gbps. They offer chatter-free open collector TTL LOS outputs with adjustable LOSlvl threshold.
|
Post Amplifiers detect wide input signal range.Micrel Semiconductor Inc.
San Jose, CA 95131
Dec 24, 2007
Incorporating loss-of-signal circuit optimized to detect input signal range of 20-140 mVpp, Models SY88303BL and SY88307BL low power post amplifiers operate from 155 Mbps to 3.2 Gbps with signal amplitudes ranging from 10-1,800 mVpp and feature CML-level outputs. SY88305BL and SY88309BL have same characteristics but feature signal detect circuit and PECL-level outputs. ICs come in ultra-small 16-pin MLF® or 10-pin EPAD-MSOP packages.
|
Vector Modulator operates from 500 MHz to 2 GHz.G.T. Microwave, Inc.
Randolph, NJ 07869
Oct 31, 2007
Model SA-39-AR Integrated Digitally Controlled Pin Diode I & Q vector modulator, amplifier, and negative gain equalizer offers simultaneous 60 dB and 360° of dynamic attenuation and phase control with accuracy of 0.06 dB and 0.1° at any CW frequency. Across entire band, VSWR is 1.8:1 with +30 dB of RF gain held within ±1 dB window to output 1 dB compression point of +17 dBm. Device switches from state to state in 1.0 µs.
|
 Flow Electronics feature modular architecture.Hoffer Flow Controls, Inc.
Elizabeth City, NC 27909
Nov 15, 2006
CAT Series accepts up to 3 different circuit boards to offer options for signal conditioning, amplification, and transmission. Microprocessor-based devices include CAT1 intelligent loop powered 4-20 mA transmitter with linearization; CAT2 signal conditioner with various output options and optional High and Low flow rate alarms; and CAT3 intelligent signal conditioner with optional alarms and linearization that provides pulse output scaled per unit of flow.
|
Wireless Signal Booster suits residences and small offices.Spotwave Wireless
Ottawa K2K 3C7 Canada
Nov 10, 2006
Preventing oscillation and harmful interference, Model Z1900 wireless repeater improves indoor signal strength with coverage up to 2,500 sq ft, enabling use of cell phones and PDAs indoors. Product automatically adjusts signal levels, and works with most wireless carrier networks that offer voice or wireless data services in 1900 MHz. Booster features network-protecting technology and supports CDMA, GSM, EVDO, and UMTS.
|
Photodetector Amplifier minimizes electrical noise levels.Opto Diode Corp.
Newbury Park, CA 91320
Nov 07, 2006
Packaged in TO-5 can, ODA-5W-100M is suited for low-light-level tasks where electrical noise levels can affect photodiode signal if detector and amplifier are separate components on PCB. Photodetector amplifier combination offers 100 Mohm gain and 0.100 in. dia active area. Detector visible wavelength responsivity is 40 V/µW at 660 nm while frequency response is 1 KHz with dark offset at ±1 mV and dark offset noise at 5 mV rms.
|
 Amplifiers incorporate background-lit LCDs.Mahr Federal Inc.
Providence, RI 02905
Sep 12, 2006
Along with auto-detect mode, Millimar C1208 and 1216 feature displays with analog and 2-line digital readout. Status lamps indicate warning and tolerance limits, and 2 features can be displayed simultaneously. Millimar C1216 also has analog output with programmable output voltage and resolution from 1 µin. with measuring range of ±0.008 in. Other features include static measurements ±A, ±B, and all combinations as well as dynamic measurement of max, min, max-min, max+min, and mean.
|
Servo and Spindle Hardware promote position accuracy.GE Intelligent Platforms
Charlottesville, VA 22911
Jun 20, 2006
Modular Level-Up αi series includes spindle amplifiers, servo motors, power supplies with continuous output up to 100 kW, and 1-3 axis servo amplifiers with HRV4 control and minimal heat generation. Servo amps use single fiber optic cable to connect up to 16 servo axes, and all units utilize energy-saving power source regeneration. Servo motors utilize permanent magnet rotor, while motor-mounted, 16 million ppr encoders feature error correction learning functions.
|
(Showing headlines 1 - 20) more ....
|
Latest Products in the News |
Cellphone-Mate Inc - October 4, 2011 Cellphone-Mate®, Inc. Announces First FCC Approved, 4G LTE Single-Band Amplifier for the AT&T Network, the CM700A
AutoMate Scientific, Inc. - February 23, 2011 MED64 multi-electrode Array Amplifier
Cree, Inc. - August 28, 2007 Cree SiC MESFETs Cut Size, Boost Performance of New MILMEGA UHF Amplifiers
GE Intelligent Platforms - July 5, 2007 GE Fanuc Announces Support for Alpha HVi Series of Servo Motors and Amplifiers for General Motion Applications
GE Intelligent Platforms - September 8, 2006 GE Fanuc Automation Features Innovative Industry-Leading CNC/Servo Technology At IMTS 2006
More Products in the News...
|
|
|